Fig 4-26
LDU-20 page - STEAM PRODUCTION CONTROL
007
008
009
010
011
012
015
013
006
001
002
003
005
014
004
Tab 4-6
STEAM PRODUCTION CONTROL (SPC)
Item
Function
Effect
001
ON/OFF button
Starts or stops the SPC system
002
INDEX button
Opens the index page
003
SCREENSHOT button
Makes a screen shot of the current screen
004
RCS CTRL ON button
Gets control from the remote control system (if button is active)
005
Value indication
Shows the values
006
SPC/EXT. CONTROL button
Changes to the external control of the SPC
007
MinEWGPos mode button
Sets the minimum permitted EWG position
Other SPC modes than the initial mode MinEWGPos are only
possible, if the signal Engine ready for SPC from ECS is active
(green).
008
MaxEWGPos mode button
Sets the maximum permitted EWG position
009
ManEWGSetp mode button
Sets the EWG setpoint, if the specific LDU-20 is in control
You can set a value of 0 to 100%, but the SPC uses only a value
in the permitted range.