Marine Installation Manual
2021-08
4-23
4 Ancillary Systems
4.3 Lubricating oil systems
X72DF
Manual changeover
Alternatively, a manual changeover valve can be applied, if the specified max
-
imum sulphur content of the fuel exceeds 0.10 % sulphur m/m. This enables se
-
lection of the preferred cylinder lubricating oil (according to the fuel in use).
Figure 4
-
11 Dual cylinder lubricating oil installation without iCAT, enabling inde
-
pendent gas and liquid fuel (maximum 0.50% sulphur m/m) operation with
a manual changeover valve
ME2
LUB
LIQUID FUEL
(OIL GRADE 1)
SERVICE
TANK
ME1
LUB
ME – Main engine
LUB – Lubricator
Min. static height
according to the
specification in MIDS
M
M
M
M
TRACE
HEATING
CHANGEOVER
VALVES
(close to engine inlet)
SM-0647
GAS
(OIL GRADE 2)
SERVICE