Tab 10-12 Servo oil leakage flow from the servo oil supply unit is too high
Indication
Possible cause
Procedure
LS2055A
The servo oil unit or a servo oil pipe
is defective
•
Find the cause and repair the fault, refer to
section
10.3 Examine the supply unit for ser-
.
Tab 10-13 Servo oil flow at a servo oil pump inlet is too low
Indication
Possible cause
Procedure
FS2061-nnA
The related servo oil pump is de-
fective
•
Replace the defective servo oil pump as
soon as possible.
The alarm has an effect only above 30% of engine load.
Tab 10-14 Bearing oil temperature at a bearing outlet is too high
Indication
Possible cause
Procedure
TE2101-nnA
TE2201-nnA
TE2301-nnA
This is a result of the malfunction in
Table 10-7 - Lubricating oil supply
pressure at the engine inlet is too
low
•
Do the repair shown there.
A bearing is defective
•
Find the cause and repair the fault.
The oil does not have the specified
properties
•
Use correct oil.
Tab 10-15 Oil mist concentration is too high
Indication
Possible cause
Procedure
AE2401-nnA
(crankcase)
AE2415A
(gearcase)
AE2421-nnA (fuel
supply unit)
The oil supply system is defective
•
Find the cause and repair the fault.
Parts that move have become too
hot
•
As a temporary procedure, decrease the en-
gine load.
•
Stop the engine.
•
Wait a minimum of 20 minutes to let the en-
gine temperature decrease.
•
Find the cause and repair the fault.
X72-B
AA00-0000-00AAA-410C-A
Operation Manual
Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 394 -
Issue 003 2021-12