Replacing an Existing Wall Plate

Remove the two screws used to mount the existing wall 
plate. Once these screws are removed, carefully pull the wall 
plate far enough from the wall to reach the connections on 
the back of the wall plate. The back of the wall plate should 
look similar to one of the wall plates below.

Models before 2010

1

 = Power

2

 

= Ground

3

 = Antenna

4

 = Cable

5

 = TV2

6

 = TV1*

Models after 2010

*Some wall plates have a

cable coming out of the
front of the plate. This is
TV1.

Disconnect the 12 VDC power (     ) from the existing wall 
plate, and mark the cable as POWER. 

NOTE: not all installations will use red for power and black 
for ground; therefore, it is important to disconnect the 
wire shown as POWER (     ) on the existing wall plate.

Once the power has been disconnected, mark the cables 
for ANTENNA, CABLE, TV1, and TV2. With these cables 
marked, unscrew each of these cables from the existing wall 
plate, making sure that they do not fall back into the wall.

Finally, disconnect the GROUND (     ) from the existing wall 
plate. Now, nothing should be connected to the wall plate. 
Set the existing wall plate aside; it is no longer needed. 
Proceed to 

Installing the SensarPro

.

Included:

2 Spade Connectors 
4 Mounting Screws
1 Signal Meter Spacer (connected to wall plate)

1 SensarPro Wall Plate
1 Instruction Sheet

Installing the SensarPro

On the back of the SensarPro wall plate, there are four cables. 
Each cable is labeled on the cover above the cable as shown 
below.

3

 = Antenna

4

 = Cable

5

 = TV2

6

 = TV1

Connect the cable coming from the antenna to the cable 
coming from ANT IN (     ) on the SensarPro. Repeat this for 
CABLE IN, TV1, and TV2.

If more than two televisions are needed, a splitter may be 
connected to TV2 to add televisions.

Once the four cables have been attached, connect the 12 VDC 
power from the existing wall plate to the SensarPro. The 
POWER should be connected to the post marked “

+

” (     ) on 

the SensarPro. The GROUND should be connected to the post 
marked “

” (     ) on the SensarPro. Input voltage must be 

between 9 and 16 volts DC with a maximum draw of 500 mA.

1

 = Power

2

 = Ground

With all of the cables connected, carefully feed the cables 
back into the hole in the wall. Align the mounting holes on the 
SensarPro so that they form a line perpendicular to the floor. If 
the spacer was installed, align the holes in the SensarPro wall 
plate with the holes in the spacer. See image to the left. 
Pre-drill mounting holes if this is a new installation.

Insert two of the provided mounting screws, and secure the 
SensarPro to the wall. Proceed to the 

Operation

 section.

New Installation

Begin by selecting a location 
for the Winegard SensarPro. 

Keep in mind the following 
about the SensarPro:

must be accessible

must be connected to the
antenna, television(s), and
12V DC power

will extend one inch into
the mounting surface

Try to avoid installing the 
SensarPro on an exterior wall.

Once a location has been 
selected, cut a 3.30” tall by 
1.87” wide section in the wall 
for the back of the SensarPro 
and the cables. See actual 
size template at right. If 
unable to cut out the tabs 
using the provided template,proceed to

 Installing the Spacer. 

Otherwise, proceed to 

Installing the SensarPro

.

Installing the Spacer

If not using an outlet box or if unable to cut out the tabs on the

above template, the spacer may be 
needed. (The tabs in the above template 
are not needed when using the spacer.)

To install 
the spacer, 
place the 
spacer over 
the hole cut 
out for the 
SensarPro.

Screw the spacer to the wall 
with two mounting screws. See 
image above. Then, continue 
with 

Installing the SensarPro

.

InstallatIon InstructIons

Warranty

WINEGARD MOBILE PRODUCTS LIMITED WARRANTY

(2 YEARS PARTS; 1 YEAR LABOR)

Winegard Company warrants this product against defects in materials or workmanship 

for a period of two (2) years from the date of original purchase. During year one (1) of 
such warranty, Winegard Company will also pay authorized labor costs to an authorized 
Winegard dealer to repair or replace defective products. No warranty claim will be 
honored unless at the time the claim is made, Customer presents proof of purchase to an 
authorized Winegard deal

er such as SolidSignal.com. Custo

mer must provide proof of 

purchase with a dated sales receipt for the Winegard product to verify the product is under 
warranty. If the date of purchase cannot be verified, the warranty period shall be 
considered to begin thirty (30) days after the date of manufacture.

If a defect in material or workmanship is discovered, Customer may take the product to 

an authorized Winegard dealer for service. Customer must provide proof of purchase to 
verify the product is under warranty. If the product is brought to an authorized Winegard 
dealer for service prior to expiration of year one (1) of the warranty period and a defect in 
material or workmanship is verified by Winegard Technical Services, Winegard Company 
will cover the Winegard dealer’s labor charges for warranty service. The Winegard dealer 
must contact Winegard Technical Services in advance for pre-approval of the service. 
Approval of the service is at the sole discretion of Winegard Company.

Alternatively, Customer may ship the product prepaid to Winegard Technical Services 

(located at 3111 Kirkwood Street, Burlington, Iowa 52601. Customer must return the 
product along with a brief description of the problem and provide Winegard Technical 
Services with Customer’s name, address, and phone number. Customer must also provide 
proof of purchase to verify the product is under warranty. If the product is returned before 
the expiration of the warranty period, Winegard Company will (at its option) either repair 
or replace the product.

This Limited Warranty does not apply if the product has been damaged, deteriorates, 

malfunctions or fails from: improper installation, misuse, abuse, neglect, accident, 
tampering, modification of the product as originally manufactured by Winegard in any 
manner whatsoever, removing or defacing any serial number, usage not in accordance 
with product instructions or acts of nature such as damage caused by wind, lightning, ice 
or corrosive environments such as salt spray and acid rain. This Limited Warranty also 
does not apply if the product becomes unable to perform its’ intended function in any way 
as a result of the television signal provider making any changes in technology or service.

RETURN AUTHORIZATION POLICY

A Return Material Authorization (RMA) is required prior to returning any product to 

Winegard Company or Winegard Warranty Services under this warranty policy. Please call 

Solid Signal at 877.312.4547 t

o obtain the RMA number. Please furnish the date of 

purchase when requesting an RMA number. Enclose the product in a prepaid package and 
write the RMA number in large, clear letters on the outside of the package. To avoid 
confusion or misunderstanding, a shipment(s) without an RMA number(s) or an 
unauthorized return(s) will be refused and returned to Customer freight collect.

WINEGARD COMPANY DOES NOT ASSUME ANY LIABILITIES FOR ANY OTHER 

WARRANTIES, EXPRESS OR IMPLIED, MADE BY ANY OTHER PERSON.

ALL  OTHER  WARRANTIES  WHETHER  EXPRESS,  IMPLIED  OR  STATUTORY 

INCLUDING  WARRANTIES  OF  FITNESS  FOR  A  PARTICULAR  PURPOSE  AND 
MERCHANTABILITY ARE LIMITED TO THE TWO YEAR PERIOD OF THIS WARRANTY.

In states that do not allow limitations on implied warranties, or the exclusion of 

limitation of incidental or consequential damages, the above limitations or exclusions do 
not apply.

Some states do not allow limitations on how long an implied warranty lasts, or the 

exclusion of limitation of incidental or consequential damages, so the above limitations or 
exclusions may not apply to you.

This warranty gives Customer specific legal rights. Customer may also have other rights 

that may vary from state to state.

Technical Service: 

877-312-4547

For questions, contact Solid Signal at 877.312.4547 

or e-mail [email protected].

Printed in U.S.A.  ©2011 Winegard Company  2452217  Rev2 10/11

Winegard and SensarPro are registered trademarks of Winegard Company.

www.antennaweb.org and www.tvfool.com are not affiliated with Winegard Company.

2452217

In many cases, the Winegard SensarPro signal meter will replace an existing RV antenna wall 
plate power supply. For this reason, both replacement instructions and new installation 
instructions are provided.

The signal meter spacer is needed for most installations. If using an outlet box, the spacer is 
not needed.

For more information on how to hook up your SensarPro, visit www.winegard.com/sensarpro

SensarPro Operation Instructions are included on the back of this page.

3

4

5

1 2

1.87”

3.30”

.14”

.12”

.25”

.25”

tab

ANT IN

TV

2

TV

1

CABLE IN

3

4

5

1

2

1

2

Spacer

SensarPro 

Wall Plate

3

4

5

6

1

1

2

3

1

2