To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com
ELECTRICAL
The Model
Vacuum
Cleaner operates on standard 15 amp,
A.C. household current 220 volt
option available. Voltages below 105
volts, or above 125 volts, will cause
potentially serious damage to the
motors.
Thirty-five feet of
STJO cable with
a 3-prong plug is the power connection
to
the machine.
This system has 3 main units:
1.
Cabinet assembly with vacuum
motors, and attached electrical
cable.
2. Dome and
chamber
and cage.
3. Waste bucket.
Carefully unpack and inspect all com-
ponents for shipping damage. If you
discover any damage, notify the deliver-
ing carrier immediately. Your machine
was tested and inspected thoroughly
before shipment, and damage is the re-
sponsibility of the carrier.
OPERATION
Attach vacuum hose between the wand
and floor tool and the machine.
FOR DRY PICKUP
The waste bucket MUST have at least
5” of water in it before dry pickup is
started, and the
chamber
and cage must be in place.
FOR WET PICKUP
Wet pickup should be done with the
chamber and cage in
Insert electrical plug into 115 volt, 15
amp outlet. Make sure the dome is in
place and sealed. You may be working
on wet
or wet floors,
so make
sure the machine is properly grounded.
To prevent an overloaded circuit, do not
operate on the same circuit with other
appliances.
Turn power switch ON.
WARNING:
When using for wet pickup
an overflow of water or dirt into the
vacuum motors can cause them to fail!!
Constantly monitor the level
of waste
water in the recovery bucket. When
about
full, shut off the machine,
remove the dome, take out bucket and
empty. Keep the exterior of the bucket
dry
so no moisture gets into the vacuum
chamber. Replace the bucket, center
and seal the dome and continue
cleaning.
Do not use to pick up volatile materials
or dry chemicals.
Do not expose the unit
to
rain. Always store it indoors.
Do not tip over the machine. Always
operate with
hose clipped by rope
leash to the machine.
AFTER CLEANING
Empty the waste water bucket and rinse
it
thoroughly. Wipe out tank. Wipe off
machine and wand with a damp cloth.
Clean lint from the two air screens
inside the vacuum chamber before each
use.
MAINTENANCE
Periodically inspect the surfaces, hoses,
cable, filters and connections on your
machine. All surfaces should be clean to
minimize abrasion damage. Use only
soap and water for cleaning your
machine.
Do not walk on hoses. Keep
them clean and unkinked. Frayed spots
on hoses should be covered and end
connectors kept snug. Because the
electrical cable will lie on
carpet
or
floors at times, the cable must be well
insulated and cable connector screws
should be tight.
Do not walk on the
cable or run machinery over it. If the
cable insulation is broken or frayed,
repair or replace it immediately. Don’t
take chances with an electrical fire
or
shock.
If necessary, the plastic
chamber can be removed for cleaning
by releasing the rod that holds
it
in
place. When replacing the chamber be
sure rubber gasket in dome elbow is in
place.
POSSIBLE CAUSE
SOLUTION
PROBLEM
No power to machine
Dead electrical circuit
Power switch failure.
Faulty electrical cable.
Equipment not grounded.
Electrical shock
Motor speed varies
or doesn’t run
Loss of vacuum
Motor brushes worn.
Motor worn out.
Loose vacuum dome.
Clogged water chamber.
Crack in dome or defective
glue joint.
Lint or dirt clogging vacuum
screen.
Loose cuffs on vacuum hose.
Vacuum motor seals leaking.
Floor tool vacuum chamber
plugged.
Broken
hose.
Damaged dome gasket.
Worn out
motor.
Check building circuit breaker or
fuse box.
Replace.
Replace.
Ground prong on plug broken
off. Never operate machine
with grounding prong removed.
Replace.
Replace.
Center and seal dome over tank.
Rinse out with water.
Replace or reseal using acrylic
plastic cement only.
With power off, clean screen.
Tighten cuffs turning counter-
clockwise.
Replace.
Wash out with hose. Pick lint
out with wire
Replace.
Replace.
Replace.
I
LIMITED WARRANTY
warrants to the original
that
this product is free from defects in workmanship and
materials under normal use and service for a period of
one year from date of purchase WINDSOR
at
option. repair
or replace without charge, except lor
transportation
parts that fail under normal use
and service when operated and maintained i n
accordance with the
operation and
manuals This warranty does
not apply to normal
wear, or to items whose life
dependent on their use
and care, such as cords. switches. hoses. rubber
electric motor parts. etc
IN
to the above warranty. for a period
5
YEARS WINDSOR
without charge. either re-
place
or return working order. at its option. any solu-
tion tank that fails as a result
defects in materials
or
workmanship during normal service and usage except
for transportation costs
This limited warranty is
in
lieu
of all other warranties
expressed or implied and releases WINDSOR from all
other obligations and liabilities It is applicable only in
the
A and Canada and is extended only to the
original
of this’product WINDSOR
not responsible
lor
for repairs performed by
persons other than those specifically authorized by
WINDSOR This warranty does
not apply to damage
from transportation alterations by unauthorized
persons misuse or abuse of the equipment use of
non
compatible chemicals or damage
property or
loss of
income due
to
malfunctioning of the product
If a difficulty develops with this machine you should
contact the dealer
whom it was purchased
WINDSOR
INDUSTRIES,
INC.
2635
So
Fe
Drive Denver
80223