background image

 

 

 

. . . for Continuous Improvement.

Windsor's Quality Management System is Certified 

 9001.

Operating Instructions (ENG)

UL LISTING COVERS ADP ONLY

Read these instructions before operating the machine.

98198 02/01/99

Summary of Contents for ADMIRAL PLUS ADP

Page 1: ...ADP ADPJ QUEST for Continuous Improvement Windsor s Quality Management System is Certified IS0 9001 Operating Instructions ENG UL LISTING COVERS ADP ONLY Read these instructions before operating the...

Page 2: ...appliance with wet hands l Do not put any object into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce air flow l Keep hair loose clothing fingers...

Page 3: ...the controls located at the back of the machine and on the control panel J D E A Bush Switch B Continuous Pump Switch C Vacuum Switch D Brush Motor Circuit Breaker E Intermittent Pump Switch F Vacuum...

Page 4: ...ounded outlet is not available The temporary adaptor should be used only until a properly grounded outlet Fig A can be installed by a qualified electri cian The green colored rigid ear lug or the like...

Page 5: ...0 F 60 C Make sure dome is seated correctly to en sure proper vacuum seal CAUTION Use only the suitable chemicals listed be low Using incompatible chemicals will damage the machine Damages of this typ...

Page 6: ...l start streaking and won t completely clean the carpet When the extractor runs out of cleaning solution turn off the machine drain the recovery tank as described above remove the dome and recovery ta...

Page 7: ...3 Replace and repair as necessary 4 Clean axle and apply a light coat of silicon lubricant before reassembling SWITCH CONTROL PANEL The switches and circuit breakers are ac cessed through the panel lo...

Page 8: ...nk and vac intake screen inside dome Flush the system Fill solution tank with 1 or 2 gallons 4 8 liters of clean ot water With machine over floor drain turn on vac pump switch until solution tank is e...

Page 9: ...ct spray pattern of jets replace or clean as needed Check the tension of the solution valve cable tighten if necessary Inspect the vac motor remove any lint build up at cooling intake service carbon v...

Page 10: ...nnections inside the machine at the switches and terminal block Follow grounding instructions exactly Have an electrician inspect the building s wiring Ensure that the machine s wiring matches the app...

Page 11: ...vinegar Lubricate lightly with silicone base lubricant Make several passes at right angles to each other Use a prespray Replace spray jets which are producing more than a fine mist Clean solution filt...

Page 12: ...tor will need to be replaced or sent to a qualified service center to restore vac performance Important These brushes wear quicker as the length shortens due to increased heat Spring inside brush hous...

Page 13: ...ust x 12 8 54070 Muffler Asm ADM Vac exhaust 9 57039 Nut 1 5 NPT flange 10 29135 Deflector ADM UL Vac exhaust 1 11 70363 Scr 10 32 x 3 8 PHTR 12 87018 Washer lO Star 13 70011 Scr l 4 20 x 5 8 HHCS 14...

Page 14: ...VAC SHOE ASSEMBLY AND BRUSH PRESSURE MECHANISM 14 I 98198 10 1 98...

Page 15: ...4 20 x 1 0 HHCS Spacer Roller Bracket Brkt Roller Mounting Washer l 4 Star Pin l 16 x 314 Cotter Washer 1 4 ID x 5 8 OD Washer 3 8 ID x 3 4 OD Nylon Scr l 4 20 x l 2 HHCS Nut l 4 20 Lock 3 8 16 Lock...

Page 16: ...C HOSE ASSEMBLIES NOTE Each tank has a filter screen which protects the machine s internal parts from damage Ensure that these screens are in place and clean before operating the machine 16 ADP 98198...

Page 17: ...64 75251 50622 50534 50503 87013 Hose l 2 Wirebound X 10 Hose Drain w sol n Level ADP Hosebarb 3 8 NPT x l 2 Tee Open Nut l 4 20 w Star Washer Set Scr l 4 20 x 1 0 Open Retainer Hose Screw l 4 20 x l...

Page 18: ...asy to clean or replace 1 With tanks empty tilt machine back Rinse in hot water or use compressed air to clean Nozzles can also be soaked in an acetic acid solution white vinegar CAUTION Do not use pi...

Page 19: ...lveretainer Clamp 7 16 Dia Nylon Scr 10 32 x l 2 PHMS Washer lO Star Nut 1 32 Captive J Pump 115v ADP Nipple 1 4 Close Hosebarb l 4 MFT x 3 8 90D Tee 1 4 FFT 25 26 31016 87015 Elbow 1 4 NPT street Was...

Page 20: ...20 98198 7 1 97 CONTROL PANEL MAIN HANDLE ASSEMBLY...

Page 21: ...006 70361 41144 70117 48012 87067 41236 89114 05076 73214 70189 20084 67073 Cord End 115V 15 A NEMAS 15P Scr IO 32 x 1 2 PHTR plt Hook Cord Shoulder Bolt 5 16 OD x 1 OL Knob Adm Handle 5 l6 l 8 Washer...

Page 22: ...t cover To replace the belt it is necessary to loosen the motor and remove the brush The preset belt tension is correct when the motor and belt are securely back in place Check pulley alignment and co...

Page 23: ...t 1 4 20 Captive 15A 15B 88552 88883 Wire 16 Wht l8 76028 x 76046 Wire 13 Blk l8 76040 x 76046 I 15C 16A 16B 88884 53093 53173 Wire 14 Grn l8 76008 x 76008 Motor 115V Brush Motor 1 OOV Brush 17 18 870...

Page 24: ...98198 7 15 98 24...

Page 25: ...We supply the power I 98198 7 1 97...

Page 26: ......

Reviews: