3
REV D
60706-233
SPECIFICATIONS
GENERATOR
Model WL12000HE/K
&
L
Surge
Watts
12,000
Continuous
Watts
10,800
Volts
120/240
Amps 90/45
Generator Manufacturer
Mecc Alte Spa
Generator Model Number S20FS-160/A
Part
Number
351836-1
Rotor Resistance
6.57 Ohms
Stator Resistance
0.124 Ohms
Cap Winding Resistance
0.60 Ohms
Capacitors 31.5
mF
Capacitor Part Number
300323-112
ENGINE
Engine Manufacturer
Honda
Engine Model Number
GX630R
Type
VXE1
NH1
Code 653951
Spark
Plugs
ZFR5F
(NGK)
Air
Filter
17210-Z6L-010
Air Filter Pre-Cleaner
17218-Z6L-000
Oil
Filter
15400-RTA-004
Fuel
Filter 16910-Z6L-003
Spark Plug Gap
0.030 in
Intake Valve Clearance
0.006 - 0.010 in
Exhaust Valve Clearance
0.010 - 0.012 in
Oil Capacity
57 - 58 oz (1.78 - 1.81 qts)
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important information that should be understood
and followed before the installation, operation and maintenance of the
generator. Failure to follow the safety instructions in this manual could
result in serious injury or death. Keep this manual available for future
reference.
ANSI SAFETY DEFINITIONS
DANGER:
DANGER indicates an imminently hazardous situation which, if not
avoided,
will
result in death or serious injury. This signal word is to be
limited to the most extreme situations.
WARNING:
WARNING indicates a potentially hazardous situation which, if not
avoided,
could
result in death or serious injury.
CAUTION:
CAUTION indicates a potentially hazardous situation which, if not
avoided,
may
result in minor or moderate injury. It may be used to alert
against unsafe practices.
NOTE: CAUTION is also used on the unit labels and in this manual to
indicate a situation that could result in serious damage or destruction of
the equipment and possible personal injury.
1. ELECTRIC SHOCK -
The output voltage present in this equipment can cause a fatal electric
shock. This equipment must be operated by a responsible person.
A. Do not allow anyone to operate the generator without proper
instruction.
B. Guard against electric shock.
C. Avoid contact with live terminals or receptacles.
D. Use extreme care if operating this unit in rain or snow.
E. Use only three-prong grounded plugs and extension cords.
F. Be sure the unit is properly grounded to an external ground rod
driven into the earth.
2. FIRE HAZARD -
A. Keep a fire extinguisher nearby and know its proper use. Fire
extinguishers rated ABC by NFPA are appropriate.
3. NOISE HAZARD -
Excessive noise is not only tiring, but continual exposure can lead to
loss of hearing.
A. Use hearing protection when working around this
equipment for long periods of time.
B. Keep your neighbors in mind when permanently installing this
equipment.
4. CLEANLINESS -
Keep the generator and surrounding area clean.
A. Remove all grease, ice, snow or materials that create slippery
conditions around the unit.
B. Remove any rags or other materials that could create a
potential fire hazard.
C. Carefully clean up any gas or oil spills before starting the unit.
5.SERVICING EQUIPMENT -
All service, including the installation or replacement of service parts,
should be performed only by a qualified technician.
A. Use only factory approved repair parts.
B. Do not work on this equipment fatigued.