background image

W10000VE/B

W10000VE-03/A

GENERATOR

INSTALLATION & OPERATORS 

MANUAL

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as yours. 

If you should ever need to contact us concerning this unit, it will 

help us to respond to your needs faster.

MODEL _________________________________________________

SERIAL NUMBER _________________________________________ 

PURCHASE DATE _________________________________________

DEALER NAME ___________________________________________

DEALER PHONE # ________________________________________

www.wincogen.com

16200-007

Summary of Contents for W10000VE-03/A

Page 1: ...to contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURC...

Page 2: ...NG THE GENERATOR GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING 14 RECEPTACLE WIRING DIAGRAM 15 36 MONTH LIMITED WARRANTY 16 CA EMISSION CONTROL WARRANTY 16 SAVE THESE INSTRUCTIONS This manual contain...

Page 3: ...ype Code 0614 G1 Spark Plug Gap 0 030 in Intake Valve Clearance 0 007 0 0 in Exhaust Valve Clearance 0 004 0 006 in Oil Capacity 2 4 2 5 qts 78 80 oz TESTING POLICY Before any generator is shipped fro...

Page 4: ...HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or...

Page 5: ...s can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 40 Amps of 240 volt current at C Check the appliance or tool nameplates for the current...

Page 6: ...h can be cumulative GASOLINE When using gasoline always use fresh clean unleaded fuel The engine is certified to operate on unleaded gasoline with a minimum octane rating of 87 or higher Gasoline cont...

Page 7: ...he negative battery cable to the bat terminal Make sure all connections are clean an tight Reverse the sequence when disconnecting disconnect the negative cable first These engines produce enough dire...

Page 8: ...urs 100 hours 100 hours CHOKE RUN COMMERCIAL POWER BRIGGS STRATTON TM R NOTE The starter life is improved by using shorter cycles with time to cool off between cranking cycles Do NOT operate the start...

Page 9: ...at to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references STANDARD PORTABLE GENERATOR Your WINCO portable generator ships with a bonded neutral You ca...

Page 10: ...operation of motors lights and most appliances However electronic equipment and clocks will be affected if correct RPM is not maintained See Load vs Output chart Although individual units and models v...

Page 11: ...Meter when applying load This will ensure the generator is balanced Balanced Unbalanced 120 Volt and 240 Volt receptacles are provided for connection to various loads The diagram below represents thi...

Page 12: ...ngines Gasoline for the closest engine repair center or ask the dealer from whom you purchased the power plant 1 Change the oil after the rst 5 hours of operation and yearly or 100 hours thereafter un...

Page 13: ...r y under Engines Gasoline epair center or ask the dealer sed the power plant r the rst 5 hours of operation s thereafter under normal op ange engine oil every 50 hours ne is operated under heavy t te...

Page 14: ...it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical service technician...

Page 15: ...15 OMP 132 D RECEPTACLE WIRING DIAGRAM G2 G2 G1 GND GND GND GND GND N N N N N G1 G1 G1 G1 G1 G1 G2 G2 G2 G2 G2...

Page 16: ...nd Purchaser s sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use...

Reviews: