background image

9

OPM-155/A

and is available electronically through our website or 

by requesting a copy from the factory. The unit should 

be mounted to allow ample working room around it. A 

general rule to follow is to allow 24 inches or more of 

clearance for maintenance. Follow local codes for clearance 

from combustible surfaces.

INSTALLING THE FUEL LINE

WARNING: FIRE DANGER

Connecting rigid fuel line (i.e. steel or copper line) 

directly to the inlet fuel filter or fuel pump may cause 

the fuel line to crack during operation creating a 

serious fire hazard.

The fuel supply should be as close to the engine as 

possible. This will reduce the installation cost of fuel runs 

and minimize line losses. The diesel fuel supply should be 

no more than 3 feet below the fuel inlet on the pump. If 

your fuel supply is lower than three feet you may have to 

install an additional lift pump to bring the fuel up to the 

mechanical fuel pump on the engine.

The information in this manual is offered to assist you in 

providing the proper fuel for your engine. However, this 

information is only provided to inform you of the engine’s 

requirements and assist in making you aware of the 

decisions you must make. In no case should the instructions 

or information provided be interpreted to conflict with any 

local, state, or national codes. If in doubt, always consult 

your local fire marshal or fuel supplier.

Engine generator sets are properly adjusted before they 

leave the factory. Connecting a fuel supply with adequate 

supply volume is critical to reliable operation. Diesel units 

with optional base mounted fuel tanks are pre-plumbed to 

the mechanical fuel pump on the engine. 

Open skid mounted Diesel units are often supplied with 

capped inlet and return lines. The use of a sustainable 

customer supplied flexible fuel line is essential between 

the engine and fuel supply to provide a vibration break 

between your fuel supply and the engine.

LUBRICATION

Before starting the engine, check the oil level in the 

crankcase. If it is low, refill to the full mark with the proper 

weight/grade of oil as recommended by the engine 

manufacturer’s maintenance instructions. The necessity of 

using the correct oil, and keeping the crankcase full, cannot 

be over emphasized. Failure to use the proper oil and keep 

the crankcase properly filled will cause excessive engine 

wear and shorten its useful life.

Winco recommends our 5W-40 fully synthetic heavy duty 

engine oil to give you maximum cold weather protection 

while maintaining excellent performance in warmer 

weather. We have partnered with a national lubrication oil 

manufacturer to give you access to Winco private branded 

premium oil available at comparable prices to conventional 

oils. See your dealer for additional information.

INSTALLING THE BATTERY

CAUTION

In the following battery installation procedure, check 

to be sure the DSE 7310 MKII is in the “stop” position. 

This should be your last step before initial start-up.

This unit require 4D batteries, this unit is a 24 volt system 

and requires 2 batteries. The batteries should be rated at 

a minimum of 1100 CCA. Installation of the highest CCA 

rated battery, within the correct BCI group, will increase 

cold weather starting performance. Gel batteries should not 

be used with the battery tender installed in the generator 

enclosure.

Installation and servicing of batteries must only be 

preformed or supervised by personnel knowledgeable of 

batteries and the required precautions. Keep unauthorized 

personnel away from batteries.

When installing or replacing batteries, use the proper 

group/size starting battery. The battery should be a 

maintenance-free lead acid design. Deep cycle batteries will 

not work for this application.

CAUTION: PERSONAL DANGER

NEVER dispose a battery in a fire. The battery is 

capable of exploding.

DO NOT open or mutilate the battery. Released 

electrolyte is known to be harmful to the skin and eyes 

and to be very toxic.

These engine-generator sets are all NEGATIVE ground. Be 

very careful  not to connect the battery in reverse polarity, 

as this may short circuit the battery charging system on the 

engine.

CAUTION

A battery presents a risk of electrical shock and high 

short circuit current. The following precautions must 

be observed when working with batteries:

  1. Remove watches, rings, and other metal objects.

  2. Use tools with insulated handles.

  3. Check both the battery cable ends and the battery

    posts to be sure they are free of corrosion.

  4. Always connect the battery positive cable first 

    and then connect the battery negative cable. 

When 

    removing the battery cables from the battery, 

    reverse the procedure, disconnect the negative 

first 

    and then the positive cable.

  5. Be sure all connections are tight and coat the 

Summary of Contents for DR450V4

Page 1: ...r need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCH...

Page 2: ...TER STORAGE BRINGING OUT OF STORAGE TROUBLESHOOTING TABLE 18 AVR WIRING 19 WIRING SIZE TABLE 20 DSE 7310 MKII WIRING DIAGRAM 22 AC WIRING 23 LIMITED WARRANTY 24 SAVE THESE INSTRUCTIONS This manual con...

Page 3: ...ne generator set has been designed and manufactured to allow safe reliable performance Poor maintenance improper or careless use can result in potentially deadly hazards from electrical shock exhaust...

Page 4: ...049 ohms per phase 22 C Exciter Stator Resistance 17 ohms 22 C Exciter Rotor Resistance 0 092 ohms per phase 22 C DR500V4 GENERATOR Standby Wattage 500 000 500 000 500 000 500 000 Volts 120 208 120 24...

Page 5: ...phase 22 C Exciter Stator Resistance 17 ohms 22 C Exciter Rotor Resistance 0 092 ohms per phase 22 C DR600V4 GENERATOR Standby Wattage 600 000 600 000 600 000 600 000 Volts 120 208 120 240 277 480 34...

Page 6: ...fore any generator is shipped from the factory it is fully checked for performance The generator is loaded to its full capacity and the voltage current and frequency are carefully checked Rated output...

Page 7: ...ery hold down brackets hardware e Unit components or accessory items shipped loose for on site installation f Optional accessories 3 Remove main frame hold down bolts 4 Unit can now be lifted from shi...

Page 8: ...INJURY PERSONAL INJURY Before proceeding with the installation be sure the DSE7310 is in the stop position Before proceeding with the installation be sure the Generator MLCB Main Line Circuit Breaker...

Page 9: ...oil and keep the crankcase properly filled will cause excessive engine wear and shorten its useful life Winco recommends our 5W 40 fully synthetic heavy duty engine oil to give you maximum cold weath...

Page 10: ...panel The ATS is then installed between the main panel and the emergency distribution panel Suggested circuits freezer refrigerator furnace emergency lights sump pump emergency outlet circuits etc To...

Page 11: ...sed upon the long time Ir setting of the breakers For example if the Ir of the breaker is set at 200 and the Isd is set at 1 5 the short term breaker setting is 250 amps Instantaneous Protection The d...

Page 12: ...n must be separate conduit You cannot mix AC and DC leads at the same conduit To install the wires reference the following picture Use a small flat head screwdriver to push the release spring inside t...

Page 13: ...tdown alarms are latching The fault must be removed and the STOP RESET button pressed to reset the module The icon will be flashing in the display INITIAL START UP WARNING EQUIPMENT DAMAGE Before atte...

Page 14: ...ds possibly damaging them NOTICE If for any reason during the check out procedure the voltage and frequency are not correct depress the STOP RESET button and correct the trouble before proceeding 4 St...

Page 15: ...lowest points of the cooling water pipes 4 Close any taps and check that the spring loaded covers on the nipples close completely Install the rubber plugs and the filler cap s MAINTENANCE WARNING Befo...

Page 16: ...es Top up as necessary Alternatively you can drain the coolant also drain the coolant filter 8 Drain any water and contamination from the fuel filters and fuel tank Fill the fuel tank completely to av...

Page 17: ...4 Check the drive belt s 5 Check the condition of all rubber hoses and re tighten the hose clamps 6 Close the drain taps and install any drain plugs 7 Check the coolant level Top up as necessary 8 Co...

Page 18: ...fective fuel solenoid Defective engine harness Improper battery voltage to fuel pump or fuel solenoid Engine starts then stops and alarm light comes on Engine oil pressure is low Engine has high water...

Page 19: ...made to the voltage regulator VOLTS To adjust generator output voltage Clockwise to increase voltage STABILITY To prevent voltage hunting Clockwise to increase the dampaning effect STANDARD CONNECTIO...

Page 20: ...N THHW THW 2 XHH XHHW XHHW 2 ZW 2 SIZE AWG OR KCMIL Wire Type RHW THHW THW THWN XHHW USE Wire Type TBS SA SIS THHN THW 2 THWN 2 RHH RHW 2 USE 2 XHH XHHW XHHW 2 ZW 2 44 57 75 88 101 114 132 154 176 202...

Page 21: ...21 OPM 155 A THIS PAGE INTENTIONALLY LEFT BLANK...