© by WilTec Wildanger Technik GmbH
Item 92453
Page 9
05 2022
-1
With the spark plug removed, the combustion chamber should be filled with a small quantity of oil to
prevent oxidation. After these steps, the engine can be stored in a dry room.
Maintenance schedule
Frequency
Type of intervention
Every
time
During the
1
st
month or af-
ter 20
hours
Every time or
after 50
hours
After
6
months or
100
hours
Every year
or after
300
hours
Motor oil
Check oil level.
x
Replace.
x
x
Air filter
Check.
x
Clean.
x
Replace.
x
Spark plug
Clean, adjust.
x
Replace.
x
Ignition sensor
Clean.
x
Idling
Check, adjust.
x
Play of valves
Check, adjust.
x
Oil filter
Replace.
x
Petrol filter
Clean.
x
Fuel
supply
line
Check.
After 2 years (replace if necessary)