Direction of rotation must correspond to the arrow attached or
engraved in the pump.
Check direction of rotation when motor is apart (coupling spacer
dismantled or motor not coupled to pump). If not feasible due to pump
design (pump fitted with rigid coupling) it is necessary to check that
pump shaft turns freely after the test and before final pump start.
To check direction of rotation start motor briefly and check direction of
rotation just before rotation stops. If direction of rotation must be
modified then reverse two phases in motor junction box.
It is possible to change two phases in the control cabinet on motor
starter connections. If this solution is preferred then it will be
necessary to modify the identification of the cables in the electrical
drawings too.
5.2.4
NOISE LEVEL
Noise level of a complete pump set depends on motor type and speed,
on quality and wear of flexible coupling (if concerned), on fluid velocity,
piping design, … Values given hereafter are only indicative and based on
fan cooled electric motors average noise levels.
The test must be performed on the supplied pump if the noise
level must be certified.
If noise level is higher than 85dBA, personel working in pump area
should wear hearing protections.
Pump size
Speed
(RPM)
For
maximum
flow [dB]
At best
efficiency oint
[dB]
At zero flow
[dB]
40
2900
71
66
79
41
2900
66
62
73
45
2900
71
68
69
46
2900
66
65
68
50
2900
75
69
72
51
2900
68
66
69
60
2900
72
71
73
61
2900
67
67
74
63
S2900
85
79
80
65
1450
64
62
68
68
2900
87
79
83
80(-2)
2900
85
72
74
80K
2900
79
73
76
83
2900
89
78
86
85
1450
68
65
72
88
2900
94
87
89
88(210)
2900
90
83
84
100
2900
88
81
98
105
1450
83
67
73
108
2900
86
84
84
120
1450
78
74
78
150
1450
84
74
89
160
1450
81
75
80
170
950
83
76
77
Indicative noise level given in dBA (LpA at 1 m)
5.2.5
CONNECTIONS
Suction flange axis is horizontal and the face is vertical.
Discharge flange axis is vertical and the face is horizontal.
5.2.6
PERMISSIBLE FORCES A ND MOMENTS
No other stress than the one due to fastening of pipe and pump
flanges together should apply. No stress must be applied to pump
casing by the pipe work. A pre-stress may exceptionally be applied to
flanges to compensate a pipe expansion. But in any case the resulting
forces should not exceed values given hereafter :
DN
F
(x, y, z)
(N)
M
t (x, y, z)
(Nm)
1’’1/2 - 40
415
208
2’’ - 50
520
264
3’’ - 80
520
264
4’’ - 100
832
416
6’’ - 150
1040
528
8’’ - 200
1220
670
Applied forces and moments should not be maximum at the same
time.
5.2.7
SCOPE OF DELIVERY
Pump can be delivered as a complete pump set including electrical
motor, flexible coupling, coupling guard and baseplate. It can be also
delivered without one of those parts. A CE integration certificate is then
supplied.
This instructions and operating manual is part of the pump supply and
should be delivered attached to the pump. If not, ask WILO Customer
department to get it.
ATEX pumps may be delivered with specific instrumentation. Refer
to pump technical datasheet or to acknowledgment of order to
know exhaustive scope of supply.
6
DESCRIPTION AND WORKING PRINCIPLE
6.1
PRODUCT INFORMATION
S pump is a single stage self priming pump. Several variants of
construction are available : close-coupled (without shaft coupling),
Biblock or with ball bearings assembly fitted with elastic coupling.
Close-coupled pumps use a long shaft electric motor. Biblock pumps
accept flanged normalized IEC motor. Other pumps sets use IEC B3
motors. Diesel or gasoline engines can be used for mobile or fixed
installations.
S pumps include an open impeller, wear plate(s) (rear and front wear
plates according to pump size), single mechanical seal and non-return
valve integrated in the suction flange assembly.
Zinc anodes or internal coating with Ceram C0 can be supplied as an
option for specific applications.
[A]
Suction flange with integrated non-return valve.
[B]
Priming chamber.
[C]
Inspection cover.
[D]
Drain cover or plug (depending on pump size).
[E]
Wear plate(s).
[F]
Open impeller.
[G]
Lifetime lubricated ballbearings.
[H]
Shaft.
[I]
Mechanical seal.
[J]
Air / liquid separation chamber.
[K]
Discharge flange assembly.
Summary of Contents for Wilo-Drain SP
Page 2: ......
Page 3: ...FR Notice de montage et de mise en service Wilo Drain SP 4186313 Ed 02 2013 10 Wilo...
Page 4: ...FRAN AIS 2...
Page 25: ......
Page 26: ...24...
Page 27: ...EN Installation and operating instructions Wilo Drain SP 4186313 Ed 02 2013 10 Wilo...
Page 28: ...ENGLISH 2...
Page 49: ...ENGLISH 23...
Page 50: ......
Page 51: ......