background image

NL

I

EG-verklaring van overeenstemming

Dichiarazione di conformità CE

Hiermede verklaren wij dat dit aggregaat in de geleverde uitvoering 
voldoet aan de volgende bepalingen:

Con la presente si dichiara che i presenti prodotti sono conformi alle 
seguenti disposizioni e direttive rilevanti:

Elektromagnetische compatibiliteit 2004/108/EG

Compatibilità elettromagnetica 2004/108/EG

EG-laagspanningsrichtlijn 2006/95/EG

Direttiva bassa tensione 2006/95/EG

gebruikte geharmoniseerde normen, in het bijzonder: 

norme armonizzate applicate, in particolare:

zie vorige pagina

vedi pagina precedente

E

P

Declaración de conformidad CE

Declaração de Conformidade CE

Por la presente declaramos la conformidad del producto en su estado de 
suministro con las disposiciones pertinentes siguientes:

Pela presente, declaramos que esta unidade no seu estado original, está 
conforme os seguintes requisitos:

Directiva sobre compatibilidad electromagnética 2004/108/EG

Compatibilidade electromagnética 2004/108/EG

Directiva sobre equipos de baja tensión 2006/95/EG

Directiva de baixa voltagem 2006/95/EG

normas armonizadas adoptadas, especialmente:

normas harmonizadas aplicadas, especialmente:

véase página anterior

ver página anterior

S

N

CE- försäkran

EU-Overensstemmelseserklæring

Härmed förklarar vi att denna maskin i levererat utförande motsvarar 
följande tillämpliga bestämmelser:

Vi erklærer hermed at denne enheten i utførelse som levert er i 
overensstemmelse med følgende relevante bestemmelser:

EG–Elektromagnetisk kompatibilitet – riktlinje 2004/108/EG

EG–EMV–Elektromagnetisk kompatibilitet 2004/108/EG

EG–Lågspänningsdirektiv 2006/95/EG

EG–Lavspenningsdirektiv 2006/95/EG

tillämpade harmoniserade normer i synnerhet:

anvendte harmoniserte standarder særlig:

tillämpade harmoniserade normer, i synnerhet:

anvendte harmoniserte standarder, særlig:

se föregående sida

se forrige side

FIN

DK

CE-standardinmukaisuusseloste

EF-overensstemmelseserklæring

Ilmoitamme täten, että tämä laite vastaa seuraavia asiaankuuluvia 
määräyksiä:

Vi erklærer hermed, at denne enhed ved levering overholder følgende 
relevante bestemmelser:

Sähkömagneettinen soveltuvuus 2004/108/EG

Elektromagnetisk kompatibilitet: 2004/108/EG

Matalajännite direktiivit: 2006/95/EG

Lavvolts-direktiv 2006/95/EG

käytetyt yhteensovitetut standardit, erityisesti:

anvendte harmoniserede standarder, særligt:

katso edellinen sivu.

se forrige side

H

CZ

EK-megfelelségi nyilatkozat

Prohlášení o shod ES

Ezennel kijelentjük, hogy az berendezés megfelel az alábbi irányelveknek:

Prohlašujeme tímto, že tento agregát vdodaném provedení odpovídá 
následujícím píslušným ustanovením:

Elektromágneses összeférhetség irányelv: 2004/108/EK

Smrnice o elektromagnetické kompatibilit 2004/108/ES

Kisfeszültségü berendezések irányelv: 2006/95/EK

Smrnice pro nízké naptí 2006/95/ES

alkalmazott harmonizált szabványoknak, különösen:

použité harmonizaní normy, zejména:

lásd az elz oldalt

viz pedchozí strana

PL

RUS

Deklaracja Zgodnoci WE

      

Niniejszym deklarujemy z pen odpowiedzialno ci, e dostarczony 
wyrób jest zgodny z nastpujcymi dokumentami:

  ,   !"!  ! #$ 
%  & " :

dyrektyw dot. kompatybilnoci elektromagnetycznej 2004/108/WE

    2004/108/EG 

dyrektyw niskonapiciow 2006/95/WE

    !" 2006/95/EG

stosowanymi normami zharmonizowanymi, a w szczególno ci:

'%( ! "  ",  :

patrz poprzednia strona

. %"& ")

Summary of Contents for SK 602N

Page 1: ...ntage et de mise en service it Istruzioni di montaggio uso e manutenzione el tr Montaj ve kullanma k lavuzu hu Be p t si s zemeltet si utas t s pl Instrukcja monta u i obs ugi cs N vod k mont i a obsl...

Page 2: ...Fig 1 Fig 2 Fig 3a Fig 3b 1 2 1 4 4 130 103 110 130 113 113 6 6 4 4 130 103 115 130 113 113 6 6...

Page 3: ...Fig 4 a b c Fig 5...

Page 4: ...Fig 6...

Page 5: ...ds valid at the time of going to print EC declaration of conformity A copy of the EC declaration of conformity is a component of these operating instructions If a technical modification is made on the...

Page 6: ...uries Warning implies that serious injury to persons is probable if this note is disre garded CAUTION There is a risk of damaging the product unit Caution con cerns possible damage to the product that...

Page 7: ...c tions for the pump are to be observed at all times when working on the switchgear and the pump system DANGER Danger of electric shock Work may only be carried out on the product unit if they are swi...

Page 8: ...atures outside the range 10 C to 40 C 4 Intended use Wall mounted unit for the electrical connection of single phase and three phase pumps with integrated thermal winding contacts WSK for monitoring t...

Page 9: ...N device type 5 2 Technical data Operating voltage 1 230 V L N PE 3 400 V L1 L2 L3 N PE Frequency 50 60 Hz Protection class IP55 Switching capacity AC 3 1 230 V 1 kW 3 400 V 3 kW 3 230 V 1 5 kW Power...

Page 10: ...tches are no longer suitable for multi speed pumps since their motors have deviating rated currents in the different stages which require different fuses Motor fuse protection in Wilo pumps can be ens...

Page 11: ...e switchgear for SK 622N only Red lamp Fig 2 item 2 OFF Fault free operation ON WSK error thermal winding contact tripped 7 Installation and electrical connection DANGER Risk of fatal accident Imprope...

Page 12: ...punch stampings on the side of the electric cable inlet and outlet for mounting the threaded cable connections WARNING Risk of injury Improper work on the housing can cause injuries When opening the...

Page 13: ...ent A fatal shock may occur if the electrical connection is not made correctly Only allow the electrical connection to be made by an electri cian approved by the local power supply company and in acco...

Page 14: ...to the markings on the terminal strip Fig 5 or Fig 6 The electrical connection must be established via a fixed power cable 3 x 1 5 mm2 minimal cross section equipped with a plug and socket connector o...

Page 15: ...o WSK on the pump a jumper must be connected between terminals 10 and 15 on the terminal block X1 7 2 2 Three phase mains connection 3 400 V L1 L2 L3 N PE Power supply connection Terminals 1 3 5 K1 N...

Page 16: ...lta voltage in the supply system is 230 V Power supply connection Terminals 1 K1 N and PE X1 When the delta voltage in the system is 230 V Connect one of the phases L1 L2 L3 on the contactor K1 to ter...

Page 17: ...tive run signal SBM is available as a potential free contact SSM Apply the collective fault signal at terminals 11 and 14 of relay K2 Fig 6 NOTE If there is integrated motor protection in the pump and...

Page 18: ...properly installed and connected The pump is commissioned according to the corresponding pump documentation 8 1 Operation The pump is switched on off manually by actuating the green push button latch...

Page 19: ...switched on In the case of SK 622N the red lamp is not illumi nated Greenpressureswitchon the SK 602N SK 622N is switched off Switch on the green pressure switch Figs 1 and 2 item 1 External control...

Page 20: ...e environment and risks to personal health are avoided by properly disposing of and recycling this product 1 Use public or private disposal organisations when disposing of the entire product or part o...

Page 21: ...ompatibilit lectromagn tique directive Niederspannungsrichtlinie 2006 95 EG Low voltage directive Directive basse tension und entsprechender nationaler Gesetzgebung and with the relevant national legi...

Page 22: ...2004 108 EG EG EMV Elektromagnetisk kompatibilitet 2004 108 EG EG L gsp nningsdirektiv 2006 95 EG EG Lavspenningsdirektiv 2006 95 EG till mpade harmoniserade normer i synnerhet anvendte harmoniserte s...

Page 23: ...romagn tisk s savietojam bas direkt va 2004 108 EK Elektromagnetinio suderinamumo direktyv 2004 108 EB Zemsprieguma direkt va 2006 95 EK emos tampos direktyv 2006 95 EB i ti h i ti t d ti t i k it it...

Page 24: ...ral Asia 050002 Almaty T 7 727 2785961 info wilo kz Korea WILO Pumps Ltd 621 807 Gimhae Gyeongnam T 82 55 3405890 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 7 145229 mail wilo lv Lebanon W...

Page 25: ...102 7666 Kompetenz Team Kommune Bau Bergbau WILO SE Werk Hof Heimgartenstra e 1 3 95030 Hof T 09281 974 550 F 09281 974 551 Werkskundendienst Geb udetechnik Kommune Bau Bergbau Industrie WILO SE Nortk...

Reviews: