5.

Route the connection cable to the socket/power connection
according to local regulations.

Pump is installed.

5.2.2

Portable wet well installation

The pump can be installed at any location on the application site
when carrying out portable wet well installation. Observe and ad-
here to the following points:

Secure the pump against falling over and moving (creeping)
during use.

Secure the pressure hose to the hose connection.

100 mm

4 in

240 mm

9.5 in

195 mm

8 in

335 mm 13 in

407 mm 16 in

OFF!

S1
S3

Fig. 3: 

Installation dimensions

Fill level above: Continuous duty (operating mode im-
mersed)

Fill level below: Intermittent periodic duty (operating mode
non-immersed)

OFF

Switch-off level

The following accessories are required for installation:

Hose connection with 90° pipe elbow (article number: 2057179)
Consisting of threaded flange, 90° pipe elbow and installation
accessories

5 m (16.4 ft) pressure hose, inside diameter: 42 mm (1.65 in),
including hose clip (article number: 2027642)

Site is prepared

Hose connection assembled

1.

Install the hose connection on the pressure port.

2.

Slide the hose clip over the pressure hose.

3.

Slide the pressure hose onto the hose connection.

4.

Secure the pressure hose to the hose connection using the
hose clip.

5.

Position the pump at the installation site.

CAUTION! Use a hard surface or underlay at the installation
site to prevent sinking on soft substrate.

6.

Lay the pressure hose and fasten it in the appropriate place
(e.g. drain). 

CAUTION! If the pump is placed in a full chamber,

hold the pump at a slight angle when immersing. This
causes the air to escape from the pump!

7.

Route the connection cable to the socket/power supply.

Pump is installed.

5.3

Electrical connection

Mains connection with correctly installed protective earth con-
ductor.

Residual-current device (RCD) is installed with 30 mA.

Mains connection fuse protection: max. 16 A.

Voltage (U) and frequency (f) data on the rating plate corres-
pond to the data of the mains connection.

Do 

not

 connect the pump if:

The connection cable is damaged
Have the connection cable replaced by a qualified electrician or
the customer service.

A standalone inverter is in use
Stand-alone inverters are used in autonomous power supplies,
e.g. solar power supply, and can generate overvoltages. Over-
voltages can destroy the pump.

A multiple plug socket or power strip is in use

An energy-saving plug is in use
This reduces the energy supply to the pump and the pump may
heat up too much.

Operation on start-up controls
The pump is not suitable for operation on a frequency converter
or a soft start control.

Explosive atmospheres
Do not connect and operate the pump inside potentially ex-
plosive atmospheres!

5.3.1

Connection: Pump with plug

The pump is equipped with a plug (CEE 7/7). The connection to the
mains is established by inserting the plug into the socket (type E or
type F). The plug is not watertight. 

NOTICE! The thermal motor

monitoring is self-switching. A separate connection is not ne-
cessary.

Connection to an existing switchgear

DANGER

Risk of fatal injury due to electrical current!

Improper conduct when carrying out electrical work
can lead to death due to electric shock!

• Electrical work must be carried out by a qualified

electrician!

• Observe local regulations!

To connect the pump to a switchgear, cut off the plug. Connect
the connection cable according to the connection diagram in the
switchgear.

Summary of Contents for Rexa MINI3-S

Page 1: ...Pioneering for You Wilo Rexa MINI3 S 6092615 Ed 01 2022 03 en Installation and operating instructions...

Page 2: ...Rexa MINI3 S http qr wilo com 413 Rexa MINI3 https qr wilo com 405...

Page 3: ...n 6 2 2 Technical data 7 2 3 Type key 7 2 4 Scope of delivery 7 2 5 Functions 7 3 Application use 7 3 1 Intended use 7 3 2 Improper use 7 4 Transport and storage 7 5 Installation and electrical connec...

Page 4: ...in grey Damage to property Safety instructions start with a signal word and are displayed without a symbol Signal words DANGER Failure to follow the instructions will result in serious injuries or de...

Page 5: ...5 A2 1 8 Transport and storage Wear protective equipment Always carry the product by the handle Clean product and disinfect if necessary Dirt fosters the formation of germs Encrustations may lead to t...

Page 6: ...ct customer service If the seal is defective the oil enters the pumped fluid and the sewer Collect waste oil by type unmixed and dis pose of it in accordance with regulations at a certified collection...

Page 7: ...ins frequency 5 50 Hz 6 60 Hz 23 Rated voltage code A Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 2 4 Scope of delivery Pump Installa...

Page 8: ...valve non return valve Lay the discharge pipe frost proof Air pockets in the pump and in the discharge pipe can lead to delivery problems Installing the ventilation systems E g Air vent valve In the...

Page 9: ...ng This causes the air to escape from the pump 7 Route the connection cable to the socket power supply Pump is installed 5 3 Electrical connection Mains connection with correctly installed protective...

Page 10: ...itch The minimum requirement is a thermal relay motor protection switch with temperature compensation differential trip and re activation lock according to local regulations Set the motor protection s...

Page 11: ...week repeat the test run every month 6 4 During operation CAUTION Do not allow the pump to dry run Do not run the pump without fluid dry run Switch off the pump once the residual water level has been...

Page 12: ...ilable 1 Ensure that the plug or bare cable end is packed and stored in a watertight manner 2 Rinse the pump and cable under clean running water 3 To clean the inside of the pump guide the water jet i...

Page 13: ...e pressure hose Remove any kinks in the pressure hose 2 Suction port strainer silted clogged Shut down the pump remove it and clean it 3 Air in the pump pressure pipe Position the pump at a slight ang...

Page 14: ......

Page 15: ......

Page 16: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: