Faults, causes and remedies
en
Installation and operating instructions Wilo-Atmos GIGA-I/-B
63
Screw connection
Tightening torque
Nm ± 10 %
Post
Size/tensile strength class
Installation information:
1)
Lubricate the thread with Molykote® P37 or comparable.
2)
Tighten the screws uniformly, keep the gap even on both sides.
3)
Rescrew and tighten every screw separately.
Table 5:
Screw tightening torques
11
Faults, causes and remedies
WARNING
Have faults remedied by qualified personnel only! Observe all safety in-
structions!
If the malfunction cannot be rectified, consult a specialist technician or the nearest
Wilo customer service or representative location.
Faults
Causes
Remedies
Pump does not start or
stops working.
Pump blocked.
Electrically isolate the motor.
Remove the cause of the
blocking. Motor blocking:
Overhaul/replace motor/motor
impeller unit.
Incorrectly installed mech-
anical seal.
Remove the mechanical seal;
replace defective parts; install
mechanical seal in accordance
to the instructions.
Cable terminal loose.
Check all cable connections.
Fuse protection defect.
Check fuses; replace faulty
fuses.
Motor damaged.
Have the motor checked by the
Wilo customer service or a spe-
cialised service centre and re-
paired if necessary.
Motor protection switch
has triggered.
Set the pump to the rated
volume flow on the discharge
side (see rating plate).
Motor protection switch set
incorrectly
Set the motor protection
switch to the correct rated cur-
rent (see rating plate).
Motor protection switch af-
fected by excessive ambi-
ent temperature
Move the motor protection
switch or protect it using heat
insulation.
PTC thermistor tripping unit
has triggered.
Check the motor and fan cover
for contamination and clean
them if necessary.
Check the ambient temper-
ature and, if necessary, set the
ambient temperature to
≤ 40 °C by forced ventilation.
Summary of Contents for Atmos GIGA-B
Page 2: ......
Page 3: ...Unmounting the mechanical seal Fig I Fig II 2 1 1 1 Fig III Fig IV 50 Fig V Fig VI 4 4 1 2 3...
Page 4: ...Fig VII Fig VIII 2 1 3 Fig IX Fig X 3 2 1 Fig XI...
Page 5: ...Mounting the mechanical seal Fig XII Fig XIII 1 Fig XIV Fig XV 1 2 3 Fig XVI Fig XVII...
Page 6: ...Fig XVIII Fig XIX 1 2 1 Fig XX Fig XXI Fig XXII Fig XXIII 1 1 2...
Page 7: ...Exchange of Motor Fig XXIV Fig XXV 1 8x Fig XXVI Fig XXVII Fig XXVIII...
Page 10: ......
Page 11: ...11 Chinese simplified 12 English 37...
Page 13: ...zh CHS Wilo Atmos GIGA I B 13 1 1 1 1 2 WILO SE 2022 1 3 Wilo 2 2 1 2 2...
Page 14: ...zh CHS 14 WILO SE 2022 06 2 3 RCD 2 4 2 5 2 6...
Page 15: ...zh CHS Wilo Atmos GIGA I B 15 2 7 2 8 IEC VDE 8 3 3 1 3 2 3 3 Wilo...
Page 16: ...zh CHS 16 WILO SE 2022 06 3 4 30 kg 30 Atmos GIGA B...
Page 17: ...zh CHS Wilo Atmos GIGA I B 17 4 4 1 Atmos GIGA I Atmos GIGA D Atmos GIGA B 4 2...
Page 21: ...zh CHS Wilo Atmos GIGA I B 21 1 Qmin Qmin Qmin 10 x Qmax 7 4 Wilo 200 mm...
Page 24: ...zh CHS 24 WILO SE 2022 06 r 5 x DN d s r 2 5 d 2s Fig 4 3 4 8 5 8...
Page 27: ...zh CHS Wilo Atmos GIGA I B 27 Wilo 9 1 9 2 1 2...
Page 28: ...zh CHS 28 WILO SE 2022 06 2 Fig 7 NPSH NPSH 1 L1 L2 V1 V2 W1 W2 9 3 9 4 9 5...
Page 29: ...zh CHS Wilo Atmos GIGA I B 29 3 Fig 8 10 10 Wilo...
Page 30: ...zh CHS 30 WILO SE 2022 06 10 1 10 2 10 2 1 Wilo 1 2 3 4...
Page 34: ...zh CHS 34 WILO SE 2022 06 Wilo PTC 40 C Wilo 6 12 Wilo...
Page 36: ...zh CHS 36 WILO SE 2022 06 13 2 www wilo recycling com...
Page 67: ......