Chapter 3
GSM Asynchronous Mode Operation
Phase/frequency analyzer
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
133
menu, just above the softkeys.
The
measurement results, resolution settings
, and display markers are similar to
the corresponding areas and fields of the standard GSM test menu.
Parameter fields of the RF
analyzer
The radio frequency to measure on and the trigger functions are set in this menu
area.
System —
Selection field to set the frequency range of the channel numbers
above 511.
Selections possible: GSM 900 / 1800 or GSM 900 / 1900.
uplink / downlink —
Selection field to specify either the uplink or the downlink
frequency range.
Selections possible: uplink or downlink.
Freq —
Entry field to set the measurement frequency for the RF analyzer.
Entry range: 800 to 1000 MHz and 1700 to 2000 MHz in increments of 10 Hz.
NOTE
To gain access to this entry field, either enter a valid GSM channel number on
the Channel entry field or enter a frequency that corresponds to a valid GSM
channel number on the Freq entry field.
NOTE
For details regarding GSM frequency ranges, check with section
“Basic speci-
fications of GSM bands” on page 109
.
NOTE
To gain access to this entry field, either enter a valid GSM channel number on
the Channel entry field or enter a frequency that corresponds to a valid GSM
channel number on the Freq entry field.
NOTE
For details regarding GSM frequency ranges, check with section
“Basic speci-
fications of GSM bands” on page 109
.
NOTE
When the frequency entered corresponds to a valid GSM channel number (on
the basis of the current settings of the two selection fields above this entry
field), the 4400 will automatically display the channel number and an offset
(if any) on the two entry fields of this line.