Specifications
IR M1
Dimensions:
19” (W) x 1.75” (H) x 8.2” (D)
(48.3 cm x 4.5 cm x 20.8 cm)
Weight:
5.2lb. (2.4 kg)
Color:
Black
Rack Mount:
Single Rack Unit
Power Supply:
International Desktop Supply
Input: 36 W, 110-240 VAC 50-60 Hz
Output: +48VDC, 0.75A center-positive
Power Switch:
Rocker switch with LED
Modulation:
FM Wideband, +50kHz deviation, 50uS pre-emphasis
Carrier Frequency:
Selectable, 2.3/2.8 or 3.3/3.8MHz
Signal to Noise Ratio:
67dB (typical)
Frequency Response:
40 to 16,000Hz, +1 dB, -3dB, electrical response
Total Harmonic
Distortion:
Less than 2%, electrical response
Audio Processor
Functions:
DSP based; Compression 1:1, 1.5:1, or 2:1; High-pass and low-pass filter frequency control
Auto Carrier Shut-Off:
Adjustable timer shuts off carrier when no audio is present. Adjustable through webpage.
Infrared Test LED:
Dual IR LED for receiver testing, monitoring, and audio signal testing.
Audio Input:
(2x) Combination 3-pin XLR, 1/4” (TRS) jack for balanced or unbalanced line level, or balanced or
unbalanced microphone with selectable phantom power
Dante:
Optional
Internal Test Tone:
400 Hz internal test tone selectable as audio input source for setup and diagnostics
Remote Configuration:
Available through embedded website
Headphone Output:
(2) 1/4" headphone jacks on front panel for monitoring CH A and CH B audio inputs
Emitter Output Jack:
Four RJ-45 ports for CAT5e cables; pr48VDC Power, RS-485 communication, and
Baseband signals for IR transmission.
Operating
requirements:
0-50ºC ambient temperature, non-condensing, non-corrosive atmosphere
Approvals:
CE, FCC, RoHS, RCM, WEEE, CB Scheme, ISED, VCCI
Warranty:
2 years on Modulator, 90 days on accessories
**
Stresses above these ratings may cause permanent damage� Exposure for extended periods may degrade reliability�
IR E4
Dimensions:
7.5” (W) x 1.4” (H) x 3.6” (D)
(19.1 cm x 3.6 cm x 9.1 cm)
Weight:
0.8 lb (362 g)
Color:
Black
Power:
48 VDC supplied by IR M1 via CAT 5e cable.
Coverage Area:
Up to 18,000 square feet (1,670 sq. m) in single channel mode
Connectivity:
+48VDC Power, RS-485 communication, and Baseband signals for IR trasmission are all provided
via a single CAT5e cable inserted into an RJ-45 jack from the IR M1.
Operating
requirements:
0-50ºC ambient temperature, non-condensing, non-corrosive atmosphere
Approvals:
CE, FCC, RoHS, RCM, WEEE, CB Scheme, ISED, VCCI
Warranty:
2 years on Emitter; 90 days on accessories
NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE