NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
TP-4723701-U
MAY 2021
Figure 3-7 Above: Night Scan Powerlite, Night Scan Powerlite Xtreme, and Night Scan Powerlite
HDT Components (Left Cover Removed); Below: Night Scan Powerlite with Profiler Parts
Figure 3-8 Night Scan Powerlite, Night Scan Powerlite Xtreme, and Night Scan Powerlite HDT
Components (Left Cover Removed)
90° Limit Switch:
This limit switch activates when the mast reaches the 90° vertical position.
The mast is driven into a rubber pad under the mast. It is activated by a magnet located on the tilt
mechanism. The lights and RCP functions are disabled until this 90° limit switch is activated.
Once activated, the RCP and lights are active for use. The limit switch is adjustable and set at the
factory. See Section 7.5.2 for optional adjustment procedure.
Base Board
Look-Up Light
Wiring/Air Access Panel
Electrical Ground Bar
Saddle
90° Limit Switch
Stowed Limit Switch
Air Control Valve Assembly
Exhaust
Mast Safety Valve
Safety Valves