S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
1-24
Original Instructions
TP-5418901-F
August 2020
In order to output the most accurate intermediate extension height, the mast should:
1. Be returned to the fully nested position where the intermediate extension height
automatically returns to zero.
2. Then be taken to the height required with little or no additional up and down movement
as this additional movement can add inaccuracies within the intermediate extension
height output.
Cycle Counts and Temperature
When the mast is nested and the UP/DOWN switch held DOWN, the Display alternately shows
the cycle count of the mast and the temperature inside the Universal Control Box. The cycle
count is used during Periodic Maintenance (Section 5.4).
Error Codes
In the event of any unexpected switch feedback, communication errors, or amp draws on the
mast, the Display will show the associated error message.
UP/DOWN Switch
The UP/DOWN Switch is:
•
Used to extend and retract the mast
•
Located on the side of the Universal Control Box
•
Protected by a switch guard and waterproof boot
•
A SPDT (Mom-Off-Mom) toggle switch
OVERRIDE Switch
The OVERRIDE Switch is:
•
Used with the UP/DOWN Switch to ignore any errors returned by the Universal Control
Box in order to extend and retract the mast
•
Located on the side of the Universal Control Box
•
Protected be a switch guard and waterproof boot
•
A SPST (Off-Mom) toggle switch
Summary of Contents for 711990491
Page 2: ......
Page 46: ...STILETTO AL OPERATING INSTRUCTIONS 1 32 Original Instructions TP 5418901 F August 2020 ...
Page 98: ...STILETTO AL OPERATING INSTRUCTIONS 7 2 Original Instructions TP 5418901 F August 2020 ...
Page 114: ...STILETTO AL OPERATING INSTRUCTIONS 9 4 Original Instructions TP 5418901 F August 2020 ...