• Constant humidity:
Touch the Humidity button
once to make the humidity
increase by 5%RH for each time. When it reaches 90%RH, touch the button
again and the display shows “Co”. Without operation for 3 seconds, it exits
humidity settings. After setting the preferred humidity, the humidifier will keep
the memory and confirm by flashing in 3 seconds. Once the display switches
to show current humidity, it means settings are set. 1 minute later, it turns back
to show preferred humidity again by slowly flashing and repeats circularly to
show current humidity and preferred humidity, and timer if set.
– When setting humidity is 16%RH higher than current humidity, devise works
in mist output level 3.
– When setting humidity is 10%RH ~ 15%RH higher than current humidity,
humidifier works in level 2.
– When setting humidity is 1%RH ~ 9%RH higher than current humidity,
humidifier works in level 1.
– When setting humidity is 1%RH lower than current humidity, humidifier will
turn into sleep state. Once setting humidity is higher than current humidity,
humidifier will re-work in previous working mode till water shortage.
– Mist output speed is adjustable under constant humidity function.
• Night mode:
Long press humidity button for 2 seconds to shut the display
down. Press any button to wake up the display. Touch the button again to
make functional operation. If you just wake up the display without further
operation, the display will shut down again after 15 seconds. Long press the
humidity button again to exit night mode.
• Timer:
There are 12 timer setting: 1,2,3,4,5,6,7,8,9,10,11,12 hours. Touch
symbol TIMER
, LED display will show the desired setting timer, for example
“01”. Touch till “-- --” display on the LED, timer setting is cancelled. Without
operation 3 seconds after setting desired time, timer stop flashing, means
timer setting is successful. Display shows the current humidity after 1 minute.
The timer shows the rest operation time every minute and decreases by 1
hour, i.e., if the timer is set at 12 hours, LED display shows 11 after 1 hour. The
humidifier will automatically stop working when time is up. There is a shortcut
for timer setting. Long press the Timer button for 2 seconds to cancel timer
setting.
• Degerming :
First touch to start heating function, display shows symbol
HEATING
. Warm mist will come out after 10~15 minutes. Second touch to
start plasma function, display shows symbol PLASMA
, plasma generator
works as well. Third touch to shut down heating function. Fourth touch to shut
down plasma function.
• Auto shut down:
Once the water in the basin is not enough to keep the
humidifier continue working, the humidifier will automatically stop working
and will warn with 3 beeps (no sound under NIGHT mode). Display will show
water shortage symbol only. Refill water tank and switch on the humidifier
to let it works again.
Summary of Contents for HU-430CW
Page 2: ......
Page 4: ...2 EN INSTRUCTION MANUAL HUMIDIFIER...
Page 22: ...20 NO BRUKSANVISNING LUFTFUKTER...
Page 40: ...38 SE BRUKSANVISNING LUFTFUKTARE...
Page 58: ...56 BETJENINGSVEJLEDNING LUFTFUGTER DK...
Page 76: ...74 FI K YTT OHJE ILMANKOSTUTIN...
Page 94: ...92 DE GEBRAUCHSANWEISUNG LUFTBEFEUCHTER...
Page 111: ...109 DE MOIST C HU 430CW...
Page 114: ...112 NL GEBRUIKSAANWIJZING BEVOCHTIGER...
Page 131: ...129 NL MOIST C HU 430CW...
Page 134: ...132 PL INSTRUKCJA OBS UGI NAWIL ACZ...
Page 151: ...149 PL MOIST C HU 430CW...
Page 154: ...152 FR MODE D EMPLOI HUMIDIFICATEUR...
Page 171: ...169 FR MOIST C HU 430CW...
Page 174: ...172 IT MANUALE D ISTRUZIONI UMIDIFICATORE...
Page 191: ...189 IT MOIST C HU 430CW...
Page 194: ...192 ES MANUAL DE INSTRUCCIONES HUMIDIFICADOR...
Page 211: ...209 ES MOIST C HU 430CW...
Page 214: ...212 RU...
Page 215: ...213 RU MOIST C HU 430CW 214 220 221 221 223 228 230 231 231 231...
Page 216: ...214 RU 8...
Page 217: ...215 RU MOIST C HU 430CW...
Page 218: ...216 RU 40 C...
Page 219: ...217 RU MOIST C HU 430CW 45 65 3...
Page 220: ...218 RU...
Page 221: ...219 RU MOIST C HU 430CW 70...
Page 222: ...220 RU 1 2 3 4 5 6 7 8 9 PTC 10 11 Buoy 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Page 223: ...221 RU MOIST C HU 430CW 30 20 C 80 40 C 1 2 15 2 1 3 1 2 3...
Page 224: ...222 RU 5 90 Co 3 3 1 16 3 10 15 2 1 9 1 1 2 15 12 1 2 3 4 5 6 7 8 9 10 11 12 01 3 1 1 12 1 11...
Page 225: ...223 RU MOIST C HU 430CW 2 10 15 3 1 1...
Page 226: ...224 RU 12...
Page 227: ...225 RU MOIST C HU 430CW...
Page 228: ...226 RU...
Page 229: ...227 RU MOIST C HU 430CW...
Page 230: ...228 RU EF 35...
Page 231: ...229 RU MOIST C HU 430CW 2 5 1000 5 4 6...
Page 232: ...230 RU Wilfa 5 Wilfa...
Page 234: ...HU 430CW_20_01...