P E R F O R M A N C E
WILDEN PUMP & ENGINEERING, LLC
12
PX15
Performance
The Effi
ciency Management System (EMS) can be used to optimize the performance of your Wilden pump for
specifi
c applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum fl
ow
.
SET
TING 4 PERFORMANCE CUR
VE
EMS CUR
VE
PX1
5 MET
AL PTFE-FITTED
TECHNIC
AL D
A
T
A
Height
. . . . . . . . . . . . . . . . . . . . . . . . . .
823 mm (32.4”)
Width
. . . . . . . . . . . . . . . . . . . . . . . . . . .
505 mm (19.9”)
Depth
. . . . . . . . . . . . . . . . . . . . . . . . . . .
406 mm (16.0”)
Ship W
eight
. . . . . . . . . . .
Aluminum 60 kg (132 lbs.)
316 Stainless Steel 90 kg (198 lbs)
Cast Iron 98 kg (216 lbs)
Air Inlet
. . . . . . . . . . . . . . . . . . . . . . . . . .
19 mm (3/4”)
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76 mm (3”)
Outlet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76 mm (3”)
Suction Lift
. . . . . . . . . . . . . . . . . . . . .
4.8 m Dry (15.9’)
9.5 m W
et (31.2’)
Disp. Per Stroke
. . . . . . . . . . . . . . . .
3.14 l (0.83 gal.)
1
Max. Flow Rate
. . . . . . . . . . . . . . .
727 lpm (192 gpm)
Max. Size Solids
. . . . . . . . . . . . . . . . . .
9.5 mm (3/8”)
1
Displacement per stroke was calculated at 4.8 bar (70 psig)
air inlet pressure against a 2 bar (30 psig) head pressure.
The Effi
ciency Management System (EMS)
can be used to optimize the performance of
your Wilden pump for specifi
c applications.
The pump is delivered with the EMS adjusted
to setting 4, which allows maximum fl
ow
.
The EMS curve allows the pump user to deter
-
mine fl
ow and air consumption at each EMS
setting. For any EMS setting and discharge
pressure, the “X factor” is used as a multi-
plier with the original values from the setting
4 performance curve to calculate the actual
fl ow and air consumption values for that spe-
cifi
c EMS setting. Note: you can interpolate
between the setting curves for operation at
intermediate EMS settings.
EXAMPLE
A PX15 aluminum, PTFE-fi
tted pump operating at EMS setting 4,
achieved a fl
ow rate of 545 lpm (144 gpm) using 253 Nm
3
/h (149 scfm)
of air when run at 6.9 bar (100 psig) air inlet pressure and 1.4 bar (20
psig) discharge pressure (See dot on performance curve).
The end user did not require that much fl
ow and wanted to reduce
air consumption at his facility
. He determined that EMS setting 3
would meet his needs. At 1.4 bar (20 psig) discharge pressure and
EMS setting 3, the fl
ow “X factor” is 0.89 and the air “X factor” is
0.81 (see dots on EMS curve).
Multiplying the original setting 4 values by the “X factors” provides
the setting 3 fl
ow rate of 485 lpm (128 gpm) and an air consumption
of 205 Nm
3
/h (121 scfm). The fl
ow rate was reduced by 11% while
the air consumption was reduced by 19%, thus providing increased
effi
ciency
.
For a detailed example for how to set your EMS, see beginning of
performance curve section.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.