Performing a Linktest
121
4. Press
Enter
. The test results are displayed.
<var>
Symbol variation within the configured accuracy. The default is 16,
meaning the symbol changes every 781 frames, the equivalent of 1E6 bits.
A higher var value results in a slower test with more reliable BER
statistics.
Linktest takes only multiples of 16. For example, if <var> is set to 32, the
symbol changes every 390 frames. If it is set to 30, it still changes every
390 frames.
If <var> is set to 16, and <acc> is set to 7, then the symbol will change
every 7,810 frames.
<pps>
Transmission speed in packets per second. The default is 60 packets per
second. A low pps value means the Linktest decreases the proportion of
test data to message data. A high pps value means that Linktest increases
the proportion of test data to message data.
wilan> linktest 2
Linktest symbol changes every 781 frames
RSSI Fade Margin BER(x1E 6) FEC corrected
Missed
Loopback
R L R L
R L
R L
Frames
Frames
-----
-------
------ ------- -----
------
-60 -60
43 43
0 0 0 0 0
781
-60 -60
46 43
0 0 0 0 0
781
-60 -60
46 43
0 0 0 0 0
781
-60 -60
46 22
0 0 0 0 0
781
-60 -60
46 43
0 0 0 0 0
781
-60 -60
43 43
0 0 0 0 0
781
-60 -60
46 43
0 0 0 0 0
781
-60 -60
46 43
0 0 0 0 0
781
Summary of Contents for LIBRA 5800 AP
Page 1: ...User Manual June 2003 Rev 0 Software Version 3 1...
Page 12: ...Notices 12 Libra 5800 Series User Guide...
Page 26: ...Description 26 Libra 5800 Series User Guide...
Page 44: ...Configuration 44 Libra 5800 Series User Guide...
Page 96: ...Field Installation 96 Libra 5800 Series User Guide...
Page 102: ...Troubleshooting 102 Libra 5800 Series User Guide...
Page 106: ...Appendix A Upgrading Software 106 Libra 5800 Series User Guide...
Page 116: ...Appendix B SNMP MIB 116 Libra 5800 Series User Guide...
Page 154: ...Menu Map 154 Libra 5800 Series User Guide...
Page 156: ...156 Libra 5800 Series User Guide...