Flow switch

For industrial heat exchangers

Model FSM-6100

Contents

1.  General information
2.  Design and function
3.  Safety
4.  Transport, packaging and storage
5.  Commissioning, operation
6.  Faults
7.  Maintenance and cleaning
8.  Dismounting, return and disposal
9.  Specifications

83790004.00 12/2020 EN

Declarations of conformity can be found online at www.wika.com

Summary of Contents for FSM-6100

Page 1: ...mo CR Italy Tel 39 0372 6404 Fax 39 0372 640490 salesflow it wika com www wika com Flow switch For industrial heat exchangers Model FSM 6100 Contents 1 General information 2 Design and function 3 Safe...

Page 2: ...all apply Subject to technical modifications Further information Internet address www wika com Relevant data sheet FV 30 10 Abbreviations definitions SPDT Single pole double throw NC Normally closed c...

Page 3: ...contrary to the intended use 3 3 Improper use WARNING Injuries through improper use Improper use of the instrument can lead to hazardous situations and injuries Refrain from unauthorised modification...

Page 4: ...ting it down hard Soot vapour dust and corrosive gases Hazardous environments flammable atmospheres Store the instrument in its original packaging in a location that fulfils the conditions listed abov...

Page 5: ...ectrical mounting The connection cable must provide basic insulation for external circuits of protection class I The instrument must be able to be switched off completely by means of a switch or a con...

Page 6: ...ken out of operation immediately Ensure that there is no pressure in the instrument and that the load circuit is switched off Protect against being put into operation accidentally Contact the manufact...

Page 7: ...dismounted instrument in order to protect persons and the environment from exposure to residual media 8 Dismounting return and disposal WARNING Physical injuries and damage to property and the enviro...

Page 8: ...le combinations ON falling flow LPM ON rising flow LPM Maximum operating flow LPM in mm L mm Mini mum Maxi mum Mini mum Maxi mum 1 25 28 15 50 25 60 150 1 25 32 28 45 100 50 110 150 1 5 40 28 50 140 6...