5 Managing Switch
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
45
5.6.6
System Time
To access this page, click System > System Time.
The following table describes the items in the previous figure.
Item
Description
Enable SNTP
Click the drop-down menu to select a defined VLAN.
SNTP/NTP
Server Address
Enter the address of the SNTP server. This is a text string of up to 64 characters con-
taining the encoded unicast IP address or hostname of a SNTP server. Unicast SNTP
requests will be sent to this address. If this address is a DNS hostname, then that
hostname should be resolved into an IP address each time a SNTP request is sent to
it.
SNTP Port
Enter the port on the server to which SNTP requests are to be sent. Allowed range is
1 to 65535 (default: 123).
Manual Time
Click the drop-down menus to set local date and time of the system.
Time Zone
Click the drop-down menu to select a system time zone.
Figure 5.14 System > System Time