NOTE 

Personnel which installs, programs, operates or maintains this device must have read and 
understood these instructions. 

 

W ARNING 

 

Personnel must be familiar with all the warnings, notes and measures described in 
these operating instructions. 

 

Protective measures and mechanisms must correspond to applicable regulations. 

 

Damaged products must neither be installed nor put into operation. In case of a defect, 
please return the device to Wieland Electric. 

 

Only connect or disconnect the device when deenergized! 

 

Never open the device! 

 

Do not insert foreign objects into the device! 

 

Keep the device away from water and naked flames! 

1

 

License information 

This device incorporates software from third-party providers under the license conditions of 
GNU General Public License Version 2. You are permitted to modify or distribute this free 
software  under  the  conditions  of  the  GNU  General  Public  License.  If  required,  you  can 
request the source code of the software covered by the GNU General Public License. You 
can find further information at:  

https://dev.openwrt.org/browser/trunk/LICENSE

 or 

http://www.gnu.org/licenses/gpl-2.0

 

2

 

Function description 

The 

wienet AP 3P ETH is a WLAN Access Point for devices that communicate wirelessly, 

which  can  also  be  configured  as  a  repeater.  Furthermore  it  can  be  connected  to  devices 
that do not have their own WLAN adapter. Because of its integrated 3-port-switch (port P1, 
P2,  P3)  up  to  three  devices  can be  connected.  It  is  delivered  configured  with  the  factory 
settings  and  ready  for  immediate  use.  The  WAP  can  be  configured  for  specific  require-
ments via an integral web interface. Access is possible via LAN or WLAN. 

 

      

          

    

 

3

 

Display- and operating elements 

LED 

Farbe  Description 

Function  

STATUS 
P1, P2 
P3 

green  LED off > 10 sec. 

LED flashes 
LED lights up 

No power supply available 
The Access Point is starting up 
The Access Point is ready for use 

DATA 
P1, P2, 
P3 

yellow  LED off > 10 sec. 

 
LED lights up 
LED flickers 

No power supply available 
RJ-45 socket not connected  
RJ-45 socket connected without activity 
RJ-45 socket connected with activity 

Button 

Description 

Function 

RES 

Press RES < 3 sec. 
Press RES 5-30 sec. 

Restart 
Restart with factory settings 

The LED's are integrated inside the RJ-45 sockets of ports P1, P2 and P3. The three green 

LED's  are  connected  in  parallel  and  therefore  turn  on  altogether.  After  switching  on  the 
power supply, it takes approx. 10 seconds for the green LED's to start flashing and about 

25  seconds  to  shine  steadily.  A  flashing  LED  indicates  that  the 

wienet  AP  3P  is  not  yet 

ready for use (boot procedure or restart), whereas a continuously lit LED indicates that the 
device is indeed ready for use (status OK). The three yellow LED's indicate the state of the 

corresponding  port.  After  switching  on  the  power  supply  the  yellow  LED's  are  flashing 
once. If a LAN connection is set up the yellow LED's show an existing connection (yellow 
LED is on) and activity (yellow LED is flashing). 

4

 

Connection with Access Point 

To ensure that a network connection can be established, your PC must be in the same 
network. 

4.1

 

Access via network cable 

1.

 

Connect the power supply. 

2.

 

Connect your PC to the 

wienet AP 3P  (port P1, P2 or P3) via Ethernet cable. 

3.

 

Enter the IP address of the network adapter manually on the PC: 

IP address 

192.168.1.2 

 192.168.1.254 

Network mask 

255.255.255.0 

4.2

 

Access via LAN 

1.

 

Connect the WLAN antenna (ANT, only 83.040.0053.0). 

2.

 

Connect the power supply. 

3.

 

Activate the WLAN connection on the PC and connect to the WLAN network. 

4.

 

Enter the IP address of the network adapter on the PC as described in 4.1, 3: 

SSID 

wienet-AP-3P 

Password 

wienet123 

5

 

Access to the Access Point web interface 

The 

wienet  AP  3P  is  configured  via  web  interface  using  a  web  browser  and  can  be  ac-

cessed as follows: 
1.

 

Open the following URL in the browser: http://192.168.1.1 

2.

 

Enter the following password in the window that opens: root 

The 

wienet AP 3P web  interface then opens. If the window does not open, please check 

the proxy settings for the browser you are using. Please do not use a proxy! 
 

6

 

Individual Configuration 

The 

wienet AP 3P is delivered configured with the  factory settings and ready  for  immediate 

use. The individual configuration  is made  via the web interface. We recommend performing 
the initial configuration using the LAN interface of the device. 
For your own security, change the password for accessing the web interface, the ESSID and 
the WLAN password as well as the host name, country code and language, if required. 
The IP address must be changed manually after delivery. You can also configure the 

wienet AP 

3P as a DHCP client (IP address retrieved from DHCP server) or as a DHCP server (IP addresses 
allocated to connected DHCP clients). 
Save: Changes are adopted in the web interface.  
Save & Apply: Changes are additionally transferred to the device. 
If changes relevant to the connection are made (e.g. ESSID, IP address, password or WLAN 
key), access to the web interface is only possible again after you connect and log on with the 
new settings. 
 

7

 

Load factory settings (reset) 

Press  the  "RES"  button  at  the  top  left  above  the  port  P3  to  reset  the  factory  settings, 
including the IP address and access data. 
Press the "RES" button for 5 

̶

 30 seconds using a paper clip while the 

wienet AP P3 is ready for 

use. Then wait until the green LED lights up (after approx. 35 seconds). The 

wienet AP 3P is 

now ready for use again. 

 

8

 

Technical data 

Operating voltage connection  
Connection type  

Plug-in female connector strip with screw terminals,  
4-pin, color green 
+ / 

 = connection for operating voltage 

PE = connection for screen grounding 

Rated voltage 

24 V DC 

Voltage range 

9 … 28 V DC 

Approx. rated current  

62.5 mA (at 24 V DC) 

Approx. rated consumption  

1.5 W (at 24 V DC) 

Reverse polarity protection 

yes 

PE connection 

yes, for screen grounding 

Connector cross section 

0.14 … 2.5 mm² 

Torque 

0.5 … 0.7 Nm 

Wire strip length 

7 mm 

WLAN 
Wireless LAN standard 

IEEE 802.11 n/g/b 

Frequency 

2.4 … 2.4835 GHz 

Transmission Power 

< 100 mW 

Data rate 

Max. 150 Mbit/s 

Safety 

WEP, WPA-PSK, WPA2-PSK 

Antenna      83.040.0052.0 
          83.040.0053.0 

Integrated 
RP-SMA socket for external antenna connection 

LAN ports 
Connection type 

RJ-45 socket, ports P1, P2 and P3 

Medium 

Twisted pair 10/100BaseT 

Screen / grounding 

PE connection (at operating voltage connection) 

Environmental conditions 
Usage area 

for fixed installation in closed housings, distributors and 

switch cabinets, in interior rooms and dry rooms, 
weather-proofed, unregulated 

Ambient operating temperature  -5 … +55 °C 
Storage temperature 

-20 … +60 °C 

Relative humidity 

5 % to 93 % 

Condensation 

Not permitted 

Mounting 
Mounting method 

Mounting on TH 35 

̶

 7.5 DIN rail 

Installation position 
          83.040.0052.0 
 
          83.040.0053.0 

 
Preferably at the start or end of the mounting rail due to 
the integral antenna, not in metal housings. 
As required, including metal housings; External antenna 
positioned outside the housing 

Weight      83.040.0052.0 
          83.040.0053.0 

Approx. 106 g 
Approx. 110 g 

Dimensions 

 

Width 

22.5 mm  

Height 

101.5 mm 

Depth       83.040.0052.0 
          83.040.0053.0 

91.5 mm 
101.5 mm 

Standards 

EN 61000-6-2, EN 300328, EN 301489-1 

Accessories  83.040.0053.0 
for 

WLAN magnetic base antenna, product-No. 
F0.000.0037.4 (not included in delivery) 

Link to EC Declaration of Conformity and further information: 
83.040.0052.0  

https://eshop.wieland-electric.com/product/83.040.0052.0

 

83.040.0053.0 

https://eshop.wieland-electric.com/product/83.040.0053.0

 

 

w

ien

et

 A

3

ETH

-A

 (

83

.04

0.

005

2.

0)

 

w

ien

et

 A

3

ETH

-A

-A

 (

83

.0

40.

00

53

.0

Reviews: