8.3
Wieland Electric | BA000341 | 02.2007
8 |
Operation
Color Designation Status
Meaning
green AS-i power
constantly on
AS-i voltage supply is correct
off
AS-i supply is missing
red AS-i fault
constantly on
Communication error at AS interface, slave does not
participate in normal data traffic (e.g. slave address
"0")
flashing
Periphery error, e.g. short circuit of AS-i voltage
off
AS-i communication is correct
yellow M ok
constantly on
Drive operational
off
Drive not operational, no supply connected
yellow M op
constantly on
Motor electronics on
off
yellow M fwd
constantly on
Motor turns CW
off
Motor does not turn CW
yellow M rev
constantly on
Motor turns CCW
off
Motor does not turn CCW
Operating state