6.5
Wieland Electric | BA000341 | 02.2007
6 |
Electrical Installation
For the podis field distributor 83.219.xx01.2, the connection to AS-i is carried out from the flat
cable via penetrating screws.
6.3 Connection of sensors and actuators
Depending on the design, digital inputs/outputs can be placed on the AS interface (see the
block diagrams in the respective device descriptions) via M12 sockets at the podis field dis-
tributor.
Order no.
A
S interf
ace
(e
xternal via M1
2)
A
S interf
ace
(internal in the podis line)
Connected to consumer (driv
e)
Connected to field distributor
Digit
al inputs
M1
2
Digit
al inputs
from driv
e
Digit
al outputs
M1
2
Digit
al outputs to
consumer
83.0.0005.
Ç
–
–
Ç
3
1
–
4
83.0.xx0. /.4
Ç
–
Ç
–
3
1
–
4
83..xx0.
Ç
–
Ç
–
2
1
1
3
83.9.xx0.
–
Ç
Ç
–
–
1
–
4
WARNING
Unused connections must be fitted with M12 caps to ensure enclosure IP65.
6.4 Drive connection
The drive is generally connected via a connecting line, which is connected either permanently
or pluggable at the podis MOT. The connection at the drive can be implemented in different
ways.
The cores of the connecting line are assigned according to the following table.
Core no. Assignment
1
L1
2
L2
3
L3
4
0 VDC
5
+24 VDC
6
Digital AS-i output A0
7
Digital AS-i output A1
8
Digital AS-i output A2
9
Digital AS-i output A3
10
Digital AS-i input E3 (supplied by 24 VDC
PE
PE
Core assignment
of connecting
line
Core assignment
of connecting
line
Table of connec-
tion variants
Summary of Contents for podis?MOT FA C 1I3O
Page 2: ......
Page 26: ...Wieland Electric BA000341 02 2007 podis MOT FA C 2I1O 1I3O Device Description 3...
Page 32: ...Wieland Electric BA000341 02 2007 podis MOT FA I C 1I4O Device Description 4...
Page 34: ...Wieland Electric BA000341 02 2007 Mechanical Installation Assembly 5...
Page 42: ...Wieland Electric BA000341 02 2007 Commissioning 7...
Page 46: ...Wieland Electric BA000341 02 2007 Operation 8...
Page 57: ...10 Wieland Electric BA000341 02 2007...
Page 58: ......
Page 59: ......
Page 60: ......