5. Screw in the penetrating screws.
• Screw all penetrating screws into the flat cable.
• Torque: 1 Nm
Conductor assignment
0/
9
1
L1
L1
2
L2
L2
3
L3
L3
4
N
N
5
+
AS-i +
6
-
AS-i -
PE
PE
PE
6. If disconnected: Reinsert the electrical plug connections between hood and base.
7. Fasten the hood with the four fastening screws.
• Ensure that the unit is tight and that no connecting cables have been pinched.
• The podis field distributor is connected to the energy bus.
6. Connection to the AS interface
Connect the AS-i interface of the podis field distributors 83.210.xxyy.z and 83.212.xx01.2 to the
AS-i network using the yellow AS-i cable.
It is recommended to establish the connection via the AS-i connecting clip and AS-i tap line.
Both parts are available as accessories from Wieland Electric GmbH (see appendix for ordering
information).
AS-i connection
NOTICE
Assignment of
contact points
Screwing in penetrating screws
Philips #1 screwdriver
with at least 45 mm shaft length
Summary of Contents for podis?MOT FA C 1I3O
Page 2: ......
Page 26: ...Wieland Electric BA000341 02 2007 podis MOT FA C 2I1O 1I3O Device Description 3...
Page 32: ...Wieland Electric BA000341 02 2007 podis MOT FA I C 1I4O Device Description 4...
Page 34: ...Wieland Electric BA000341 02 2007 Mechanical Installation Assembly 5...
Page 42: ...Wieland Electric BA000341 02 2007 Commissioning 7...
Page 46: ...Wieland Electric BA000341 02 2007 Operation 8...
Page 57: ...10 Wieland Electric BA000341 02 2007...
Page 58: ......
Page 59: ......
Page 60: ......