.4
Wieland Electric | BA000341 | 02.2007
podis
®
MOT FA C/CM/CP 3I/I4O Device Description
| 2
AS-i connection (M) X
(view from outside onto plug contacts)
Pin Brief description
Note
1
AS-i +
AS int
3
AS-i -
AS interface -
The podis MOT can be addressed using a hand-held terminal. For this purpose, the AS-i hand-
held programming device (part no. 83.209.2205.0) is connected to the addressing jack of the
podis MOT. Additional information about addressing can be found in section 7.1. "Setting the
AS-i slave address at the podis MOT".
Digital inputs X3, X4, X5
(view from outside onto socket contacts)
�
�
�
�
�
Pin Brief description
Note
1 24 V
24 V sensor supply (*)
2 IN
Digital inputs
3 0 V
0 V of sensor supply (*)
4 IN
Pin 4 connected with pin 2
5 Ground
Equipotential bonding
(*) The digital inputs at X3, X4 and X5 are supplied from AS-i (internal).
revos MOT connector
Pin Designation
Meaning
1 L1
Motor lead voltage U
2 L2
Motor lead voltage V
3 L3
Motor lead voltage W
4 0 V
0 V of external voltage(*)
5 +24 V
24 VDC of external voltage(*)
6 OUT 0
Supply for motor electronics
7 OUT 1
Motor control lead CW rotation
8 OUT 2
Motor control lead CCW rotation
9 OUT 3
Speed switching f1 / f2
10 IN 3
Ready message from motor
PE PE
PE connection
(*) The supply is provided by an external 24- V power supply.
Connection
assignment of
AS-i socket
Connection
assignment of
digital inputs
Connection
assignment of
connector at FA
CP 3I/I4O
Summary of Contents for podis?MOT FA C 1I3O
Page 2: ......
Page 26: ...Wieland Electric BA000341 02 2007 podis MOT FA C 2I1O 1I3O Device Description 3...
Page 32: ...Wieland Electric BA000341 02 2007 podis MOT FA I C 1I4O Device Description 4...
Page 34: ...Wieland Electric BA000341 02 2007 Mechanical Installation Assembly 5...
Page 42: ...Wieland Electric BA000341 02 2007 Commissioning 7...
Page 46: ...Wieland Electric BA000341 02 2007 Operation 8...
Page 57: ...10 Wieland Electric BA000341 02 2007...
Page 58: ......
Page 59: ......
Page 60: ......