Wide IDP2800SQ User Manual Download Page 1

 

 

 

Issued Date 

Revision Status 

Title 

Page No. 

1 / 77 

V5.3 

2009-06-08 

IDP2800SQ 

(SL28P2K) 

 

 

 

 

USER MANUAL 

 
 
 

IDP2800SQ 

 
 

2048 x 2048 TFT LCD MONITOR 

 

28.05" SQUARE FORMAT 

 

Air Traffic Control Application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proprietary Data Notice

This document as well as all reports, drawings, data, information, or other material, whether accompanying it are the property of 
WIDE Corporation, are disclosed by WIDE only in confidence, and, except as WIDE may otherwise permit in writing, are to be 
used, disclosed, or copied only to the extent necessary for the evaluation thereof by recipient, or higher-tier contractor or 
subcontractor. 

 

Information in this document is subject to change without prior notice.

   

 

Summary of Contents for IDP2800SQ

Page 1: ...as all reports drawings data information or other material whether accompanying it are the property of WIDE Corporation are disclosed by WIDE only in confidence and except as WIDE may otherwise permit...

Page 2: ...1 1 4 CONTROLS OF THE DISPLAY 14 1 1 4 1 REMOTE CONTROL VIA SERIAL PORTS CRT TYPE SONY DDM COMPATIBLE 14 1 1 4 2 CONTROL VIA ETHERNET FOR SNMP OPTION 14 1 1 4 3 CONTROL VIA OSD AND CONTROL MODULE 14 1...

Page 3: ...S PROVIDED 33 2 3 IP SETTING 34 2 3 1 IP ADDRESS 34 2 3 2 SUBMASK 35 2 3 3 GATEWAY 35 2 3 4 TRAP IP ADDRESS 36 2 3 5 MAC ADDRESS 36 3 CONTROL ACCESS 37 3 1 CONTROL MODULE 37 3 2 DIRECT CONTROL ACCESS...

Page 4: ...PMS 55 3 3 5 4 FAN CONTROL MENU 56 3 3 5 4 1 Control 56 3 3 5 4 2 Life time 56 3 3 5 5 TEMPERATURE MENU 57 3 3 5 6 TEST PATTERN 57 3 3 5 7 SET UP 58 3 3 5 7 1 Factory Reset 58 3 3 5 7 2 Communication...

Page 5: ...Title Page No 5 77 V5 3 2009 06 08 IDP2800SQ SL28P2K 3 3 5 7 7 6 Return 66 3 3 6 EXIT 66 APPENDIX A TROUBLE SHOOTINGS 67 APPENDIX B DDM PROTOCOL ON IDP2800SQ 68 APPENDIX C BACKLIGHT REPLACEMENT 73 AP...

Page 6: ...ed dealer or service center ON INSTALLATION 1 Openings and fans in the monitor cabinet are provided for ventilation To prevent overheating these openings and fans should not be blocked or covered Also...

Page 7: ...rvice technician Otherwise it may cause injuries Do not install this product on the place where it cannot be supported Otherwise it may cause the product to fall and could cause injuries Contact the q...

Page 8: ...lled How to identify and Resolve Radio TV Interference Problems helpful This booklet was prepared by the Federal Communications Commission It is available from the U S Government Printing Office Washi...

Page 9: ...us Title Page No 9 77 V5 3 2009 06 08 IDP2800SQ SL28P2K C C C A 1 2 LCD 3 LCD 4 LCD 5 LCD 6 LCD 7 LCD 8 LCD IEC IT IEC60950 IEC60601 IEC 60601 1 1 IEC 60601 1 1 TFT LCD 1 LCD LCD LCD 2 LCD 3 LCD LCD L...

Page 10: ...ssued Date Revision Status Title Page No 10 77 V5 3 2009 06 08 IDP2800SQ SL28P2K WIDE Corporation 456 Gomae dong Giheung gu Yongin si Gyeonggi do 446 901 Republic of Korea 82 31 218 1600 82 31 218 169...

Page 11: ...d Blue sub pixels which are arranged in vertical stripes and each sub pixel is controlled in 256 grey levels KEY FEATURES Square formatted 28 05 TFT LCD Monitor Full 2048 x 2048 resolution Multi mode...

Page 12: ...Pixel pitch 0 246 W x 0 246 H mm 0 082 x 0 082 Pixels Per Inch 103 PPI 1 1 1 5 Display mode Normally Black 1 1 2 Optical Characteristics 1 1 2 1 Protective Filter Glass Clear tempered glass Anti Refl...

Page 13: ...nal Sync TTL voltage levels External Separate H V Sync Interlace Non interlaced 2K x 2K Timing Specification Pixel Clock 357 181MHz H frequency 126 84 kHz V frequency 60 0Hz H line time 7 884 s V line...

Page 14: ...ocol RS 232 port Sub D 9p Female for WIDE protocol 1 1 4 2 Control via Ethernet for SNMP Option A Built in Lan port is available for direct connection to ethernet which enables centralized status moni...

Page 15: ...licable voltage range 1 1 7 Connectors 1 1 7 1 Power connectors Standard IEC type connector Secondary option 6 Pin LAD1140 N X Hanlim Connector 1 1 7 2 Input signal connectors Analog Input 5 Coaxial B...

Page 16: ...MDS Clock Shield 7 TMDS Clock 8 TMDS Clock DVI 1 Digital Input DVI 2 Digital Input DVI I Connection Type 29p DVI I Female Digital only support 9 TMDS Data 2 10 TMDS Data 2 11 TMDS Data 2 4 Shield 12 T...

Page 17: ...with control module provided from WIDE Download Connection Type 9p Dsub Female for download the firmware 1 No connection 2 RX_DL 3 TX_DL 4 No connection 5 No connection 6 No connection 7 Ground 8 No...

Page 18: ...the table below Monitor only Packing Height mm inch 610 0 24 01 382 0 15 03 Width mm inch 610 7 24 04 826 0 32 52 Depth mm inch 177 4 6 98 791 0 31 14 Weight kg lbs 26 0 57 3 35 0 77 21 The following...

Page 19: ...Issued Date Revision Status Title Page No 19 77 V5 3 2009 06 08 IDP2800SQ SL28P2K IDP2800SQ Bottom View IDP2800SQ Rear View...

Page 20: ...Issued Date Revision Status Title Page No 20 77 V5 3 2009 06 08 IDP2800SQ SL28P2K IDP2800SQ Top View IDP2800SQ Side View unit mm...

Page 21: ...p Type The dimension of the unit is as shown in the table below Monitor only Packing Height mm inch 752 29 60 472 18 58 Width mm inch 648 25 51 871 34 29 Depth mm inch 380 14 96 846 33 30 Weight kg lb...

Page 22: ...Issued Date Revision Status Title Page No 22 77 V5 3 2009 06 08 IDP2800SQ SL28P2K IDP2800SQ Bottom View IDP2800SQ Rear View...

Page 23: ...Issued Date Revision Status Title Page No 23 77 V5 3 2009 06 08 IDP2800SQ SL28P2K IDP2800SQ Top View IDP2800SQ Side View unit mm...

Page 24: ...Type The dimension of the unit is as shown in the table below Monitor only Packing Height mm inch 649 25 55 472 18 58 Width mm inch 648 25 51 871 34 29 Depth mm inch 215 9 8 49 846 33 30 Weight kg lbs...

Page 25: ...Issued Date Revision Status Title Page No 25 77 V5 3 2009 06 08 IDP2800SQ SL28P2K IDP2800SQ Bottom View IDP2800SQ Rear View...

Page 26: ...Issued Date Revision Status Title Page No 26 77 V5 3 2009 06 08 IDP2800SQ SL28P2K IDP2800SQ Top View IDP2800SQ Side View unit mm...

Page 27: ...see the below figure 1 Switch off and disconnect the power code before performing the disjointing 2 Unscrew the three bolts and remove it 3 Pull out the stand ASS Y 4 Unscrew the six screws and remove...

Page 28: ...IDP2800SQ SL28P2K How to disjointing stand VESA mount see the below figure 1 Switch off and disconnect the power code before performing the disjointing 2 Unscrew the three bolts and remove it 3 Pull...

Page 29: ...1 2 8 Components Industrial extended temperature range components are used for cost maintainability and reproducibility purposes 1 2 9 Cooling The Unit has two cooling fans with separate control circu...

Page 30: ...ce equipment A modular design is taken for the unit No special tools or equipment are required for maintenance purpose 1 4 2 3 Backlight replacement The IDP2800SQ has three backlight trays which are r...

Page 31: ...ow to replace the backlights see the below figure 1 Switch off and disconnect the power code before performing the backlight replacement 2 Pull out the Cover lamp 3 Disconnect the three backlight harn...

Page 32: ...from power outage Maintain a continuous supply of electric power when one power source or internal power supply board fails Power Supply will effectively switch from primary power to secondary power s...

Page 33: ...hed devices 2 1 2 MIB management information base MIB is type of database used to manage the devices in a communication network SNMP uses a specified set of commands and queries A MIB should contain i...

Page 34: ...e needed for using SNMP So must set ip address It is provided to set the IP address on the OSD menu 2 3 1 IP Address IP Adress is the submenu of TCP IP which set the IP address of the monitor User is...

Page 35: ...r User is able to set submask with rotating the encoder switch clockwise or counter clockwise For setting next digit push the encoder switch 2 3 3 Gateway Gateway is the submenu of TCP IP which set th...

Page 36: ...re some problems on the monitor it sends the notification message to the host which has this trap IP address by SNMP protocol User is able to set trap IP with rotating the encoder switch clockwise or...

Page 37: ...2 indicator LED indicator for system status In normal operation it is green and blinking red means warning system Encoder switch It is used for displaying OSD menu by pushing and also adjusting the va...

Page 38: ...SD On 3 3 5 3 1 describes SBC more detail 3 2 2 Source Selection IDP2800SQ supports to input three sources one analog and two DVI inputs One of three is able to be chosen by mean of either pushing sou...

Page 39: ...ike the general computer monitor so it is more users friendly Adjustment Adjustment Brightness Contrast Dim Brightness Sharpness Return Select Move 3 3 1 Basic Operation The menu can be changed as rot...

Page 40: ...Return Select Move Adjustment Brightness Select Move 0 select Brightness menu adjust the brightness To adjust the brightness is to remap the input data to output data in terms of black and white level...

Page 41: ...data to the output data in terms of white level only It means that if the contrast is max 100 input data over 127 is mapped to 255 so the depth between black and white is expanded On the other way if...

Page 42: ...e maximum amount of light they can produce Due to the nature of the backlight the light output drops as the backlights get older So two displays one equipped with a new set of backlights and one equip...

Page 43: ...to 0 Original Closer to 100 3 3 2 5 Return Return is for going back to the upper menu 3 3 3 Input Source The Input Source menu is for selecting one of four Analog1 DVI 1 and DVI 2 as source to displa...

Page 44: ...problem on connection or on sync signal the image are not displayed and the screen is keep black with blinking the red LED on status 1 of control module See the appendix B to get a tips for no display...

Page 45: ...that the screen is represented as below the right side figure And then DVI 1 signal is displayed locate on DVI 1 select an input 3 3 3 3 DVI 2 DVI 2 is the submenu of Input Source which sets up the di...

Page 46: ...password If user does not want others to access and to modify the setting values change the user password Advanced Settings Select Move Advanced Settings Password _ _ _ _ 3 3 4 1 Analog adjustment Ana...

Page 47: ...period The frequency should be set correct first see below and Auto Auto is disabled see the 3 3 4 2 3 Its range is 0 to 360 which is adjusted by 5 625 per one step and can be totally adjusted to 64 s...

Page 48: ...of clock 3 3 4 1 3 H Position H Position is the submenu of Analog adjustment which controls the horizontal position of image Its adjustment range is 0 to 100 and default is 50 When the H position of t...

Page 49: ...ion shifts the vertical position of image If the value of V position is increased or decreased by rotating the encoder switch clockwise or counterclockwise the V position shifts the upper or the lower...

Page 50: ...ource is always displayed When the manual item is set to off it is operated according to priority to set up And if the power switch is turned off and on the highest priority s input source is displaye...

Page 51: ...Password Advanced setting is protected on user level by password A default is 0000 but User can change it on this menu A number you want can be obtained by turning menu control switch and pressing it...

Page 52: ...nd push to select it The user password is programmable at the administrator level The factory default passwords is Administrator Password 0000 It can be changed in the set up menu which is the submenu...

Page 53: ...er of monitor The serial number is unique on every monitor 3 3 5 2 2 S W ver S W ver describes the version of software installed on monitor 3 3 5 2 3 Temp Status Temp Status describes the current inte...

Page 54: ...Primary You can see this word when primary power is activated Secondary You can see this word when secondary power is activated 3 3 5 3 Back light Menu Back light Menu is menu for setting and reading...

Page 55: ...ght life time and setting backlight lifetime warning and fault levels Warning at is menu item to set the warning level being the amount of backlight tray lifetime hours after which a warning is indica...

Page 56: ...ng 5 minutes repeatedly 10 15 and 20 are also the same operating depending on the setting time Select Move Admin Settings Fan Control AUTO 5 10 15 20 3 3 5 4 2 Life time This menu is for showing the f...

Page 57: ...nistrator Fault at represents the temperature to able to create the critical trouble of main board or power supply and the status2 led blinked red when it is more than at fault s hours The factory set...

Page 58: ...is the submenu of Admin Settings which controls the factory reset communication Auto Color RGB Black Level RGB Gain and OSD set up 3 3 5 7 1 Factory Reset Select Move Admin Settings Factory Reset Yes...

Page 59: ...ge zero to nine in order to identify the monitors and it must be unique for distinguishing from each other And In the case of chaining several monitors thru communication port the ID of monitor to be...

Page 60: ...ply with gamma 2 2 3 3 5 7 3 2Auto Color Available only in analog mode Auto color is for calibrating a RGB black level and a RGB gain automatically in initial state of ADC analog to digital converter...

Page 61: ...Color Yes No This OSD is displayed when it is enabled 3 3 5 7 3 3RGB Black Level Available only in analog mode RGB Black Level is the submenu of RGB Adjust for adjusting R G and B black level individ...

Page 62: ...the color to adjust looks like strong On the other way if it goes to OSD 0 the amount of color to adjust is less so the color is felt weakly If the color is changed in darker level adjust the black le...

Page 63: ...4 OSD Setup OSD Set Up is the submenu of Set Up which sets up the Brightness display and OSD Timeout 3 3 5 7 4 1Brightness Display Dim Brightness can be adjusted directly without navigating OSD see 3...

Page 64: ...ower warning display is the submenu of OSD Setup If this menu is setted to on when primary power AC power is failed it ll switch the power to secondary adapter and display Secondary power activated on...

Page 65: ...Quick Searching Mode If Quick Search Mode is On the detection time of source is minimized 3 3 5 7 7 TCP IP TCP IP menu is for SNMP Simple Network Mangement Protocol 3 3 5 7 7 1IP Address IP Adress is...

Page 66: ...rap IP address of the monitor When there are some problems on the monitor it sends the notification message to the host which has this trap IP address by SNMP protocol 3 3 5 7 7 5Mac Address Mac Adres...

Page 67: ...o picture on the screen When the soft power is off LED s are red color but no blinking You should wake up the main controller by pressing the Soft Power button See the 3 1 control module to refer to t...

Page 68: ...nd keeping the default values And if you need to modify the setting please contact to us B 1 Connection The 15p D sub Female type Connector is available on IDP2800SQ for emulating SONY DDM Protocol th...

Page 69: ...6Ah All Black All Black 6Bh Gray Gray User Contrast A0h and User Brightness A1h User Contrast command can control the contrast in IDP2800SQ and User Brightness can adjust the Dim Brightness in IDP2800...

Page 70: ...CRT based monitor like SONY DDM But IDP2800SQ support the status command and IDP2800SQ reply the pre defined data of bytes not to be applicable And also the major system status and board status bytes...

Page 71: ...lamp at the bottom side is burned out or the inverter at the bottom side has an abnormality B2 No incoming signal to panel B1 Life time of lamp is over warning time recommend to replace the lamp defau...

Page 72: ...the display IDP2800SQ simply replies to the commands like following DDM monitor interface manual Convergence 10h 13h Focus 14h 16h Geometry 20h 2Fh Purity 30h 36h Video 40h 4Ah Increment and Decremen...

Page 73: ...replacement instructions are depicted provisionally here below by means of pictures The IDP2800SQ backlight consists of three easily removable and replaceable backlight trays For optimum backlight un...

Page 74: ...Title Page No 74 77 V5 3 2009 06 08 IDP2800SQ SL28P2K For replacing backlight trays first remove the screws to fix the metallic cover and put the cover out And then disconnect the cable between backli...

Page 75: ...Date Revision Status Title Page No 75 77 V5 3 2009 06 08 IDP2800SQ SL28P2K Then remove the screws to fix the trays and pull out the trays The procedure to assemble is the exact reverse screws Backligh...

Page 76: ...ng out a fan replacement and disconnect the power cord and signal cables Warning Must remove the secondary power Adapter not to get shocked The IDP2800SQ fan replacement instructions are depicted prov...

Page 77: ...us Title Page No 77 77 V5 3 2009 06 08 IDP2800SQ SL28P2K Then pull off the fan connector from the board Remove four screws of the fan to be changed Then change fans with new ones The procedure to asse...