background image

 

   

WHYNTER 14,000 BTU PORTABLE AIR CONDITIONER AND 

HEATER WITH 3M SILVERSHIELD FILTER PLUS AUTOPUMP 

 

Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before 

using this product. Keep this manual in a safe place for future reference. 

Model # : ARC-148MHP 

INSTRUCTION MANUAL

 

Summary of Contents for ARC-148M

Page 1: ...LVERSHIELD FILTER PLUS AUTOPUMP Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a saf...

Page 2: ...ORMATION 3 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 INSTALLATION 9 11 OPERATION INSTRUCTIONS 12 14 REMOTE CONTROL 15 CARE AND MAINTENANCE 16 TROUBLES...

Page 3: ...product can be obtained from your local municipal au thority Thank you for choosing the Whynter 14 000 BTU Portable Air Conditioner and Heater with 3M Sil vershield filter Please follow the instructi...

Page 4: ...sh the exhaust hose while in use Always allow at least 20 of clearance around the unit for ventilation Do not use this unit inside closets cabi nets and or cramped spaces between furniture This unit i...

Page 5: ...CO FRIENDLY CFC free GREEN R 410A refrigerant and lead free RoHS compliant components TECHNICAL DATA Model ARC 148MHP Operational Modes Auto Air conditioner Fan Heater or Dehumidifier Cooling Capacity...

Page 6: ...Vent Louvers Casters four Upper Air Filter Air Outlet Vent Power Cord Upper Air Intake Upper Drain Port Lower Air Filter Lower Air Intake Compressor Lower Drain Port Power Plug Socket use when storing...

Page 7: ...uces the risk of fire due to arcing faults in the power supply cord Please follow the instructions below to ensure that LCDI plug works properly 1 Plug the power cord to a grounded wall outlet Do not...

Page 8: ...the air flow direction Up and Down Buttons Adjusts set temperature 1 C 2 F incre ments or timer hours 0 24 hours This unit is capable of displaying set temperature in Fahrenheit or in Celsius To conv...

Page 9: ...e remaining 2 of moisture will be collected in the water tank of the air conditioner When the water reservoir reaches its maximum level the unit will beep 8 times and the digital display will show P1...

Page 10: ...ngth We do not recommend extending the exhaust hose more than 9 long If you are interested in purchasing an addi tional 5 exhaust hose please contact info whynter com for retail sales information WIND...

Page 11: ...to the length and seal the open gap between the top window sash and outer window sash Shown in Fig 5d WINDOW KIT INSTALLATION IN A SLIDING WINDOW DOOR 1 Open window or sliding door for approx imately...

Page 12: ...ngs DRY DEHUMIDIFYING ONLY MODE In this mode the air conditioner only dehumidifies the room the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to...

Page 13: ...up to 10 hours followed by 1 hour increment up to 24 hours When the delay time set has elapsed the air conditioner switches off To cancel the delayed switch off function turn off the air conditioner...

Page 14: ...igh pitched sound Water running from the evaporator to the water tank may make a splashing sound Refrigerant flowing may make a gurgling sound Fan sound may come from front and back air vents COMPRESS...

Page 15: ...1 5V Batteries included in the remote control Always change both batteries at the same time INDICATOR FUNCTION 1 Mode Indicator Displays the current selected mode Auto Cool Dry Heat or Fan 2 Lock Ind...

Page 16: ...the filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner Use a soft damp cloth to...

Page 17: ...its time delay The set temperature is too high The internal water reservoir is full and P1 appears on display This unit is designed to work in ambi ent temperatures of 63 F to 90 F Press the MODE butt...

Page 18: ...it is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and h...

Page 19: ...hip Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by we...

Reviews: