35
11.2
Wheel sensor Heights and Operation
Procedure for height adjustment and testing operation are covered in Section 12.9.
11.3
Pump Setting
The Electro 10 & 20 Lubricators are controlled and set by a control panel located inside the cabinet. This
control panel allows the user to set the grease output from the blades with respect to the rail traffic
using rail.
1)
Power Switch – This toggles the power to the controller ON when in the up position and OFF when in the
down position. There is a clear protective rubber cover to keep the switch liquid tight. DO NOT try and
remove this cover.
2)
Wheel Increment Button – This increases the wheel setting for enabling pump activation, and the setting
for Loco Skip when enabled (see 7) by an increment of one each time the button is pressed. Hold down
the button and it will increment at a steady rate.
3)
Wheel Decrement Button – This decreases the wheel setting for enabling pump activation, and the setting
for Loco Skip when enabled (see 7) by a decrement of one each time the button is pressed. Hold down the
button and it will decrement at a steady rate.
4)
Pump Decrement Button – This decreases the pump output setting by a decrement of one each time the
button is pressed. Hold down the button and it will decrement at a steady rate.
5)
Pump Increment Button – This increases the pump output setting by an increment of one each time the
button is pressed. Hold down the button and it will increment at a steady rate