DESCRIPTION

OPERATION

SPECIFICATIONS

Material

...........................................Stainless Steel, Aluminum

0

0

Temperature Range

.................................... -40  F to +185 F

Switch Rating

................................................2.5VA/240 VDC

Epoxy Encapsulated

............UL LISTED EL-CAST VFR 641

Alarm/Shutdown

............. Factory default for 3 minute alarm

Power

..............................Field Replaceable -  Lithium Battery

Battery

................................................................. P/N 000505 

Alternate Battery

...............................Radio Shack 960-0418

Divider Block Application............

..Dropsa/Lincoln/SBCO/

                                                                                    Lubriquip

Warranty

...................................................................2.5 Years

MONITORS  MOVEMENT  OF  DIVIDER
VALVE PISTON  FOR  DEPENDABLE  
"TIMED" SHUTDOWN PROTECTION

CLOSED  LOOP OR OPEN LOOP OPERATION
 
INSTALLS  DIRECTLY  TO  DIVIDER  VALVE

NOT  AFFECTED  BY  TEMPERATURE OR  OIL  
VISCOSITY

REQUIRES  NO  EXTERNAL  POWER

LED  INDICATOR - CYCLE INDICATION

DEDICATED SWITCH CLOSURE TO MONITOR
EACH DIVIDER VALVE CYCLE (PS OPTION)

FIELD REPLACEABLE BATTERY

507LIT LED-WI-1

07.11.01

RATINGS

R

DIGITAL NO-FLOW TIMER

U.S. PAT. NO. 5,835,372

DNFT

DNFT-LED-PS

P/N: 000507

DNFT-LED-PS

DIGITAL NO-FLOW TIMER

R

3 - M I N

3 - M I N

2.5VA / 240VDC 

2.5VA / 240VDC 

LED-PS

LED-PS

U.S. PAT. NO. 5,835,372

RED-Open Loop   ORANGE-Closed Loop    GRN-Ground    YEL -Prox. SWI.

MODEL

RATED

SERIAL #

 PN

ALARM

Factory Sealed

CYCLE INDICATION

0 0 0 5 0 7

0 0 0 5 0 7

ODESSA, TX USA

INSTRUMENT

INSTRUMENT

WHITLOCK 

WHITLOCK 

1-800-337-34121-800-337-3412

www

.noflo.com

www

.noflo.com

ODESSA, TX USA

INSTRUMENT

INSTRUMENT

WHITLOCK 

WHITLOCK 

1-800-337-34121-800-337-3412

www

.noflo.com

www

.noflo.com

Distributed by:

The DNFT-LED is a totally enclosed electronic device, combining 
the latest technology in microprocessor and transistor 
components for detecting Slow-Flow and No-Flow of divider block 
lubrication systems.   The DNFT incorporates an oscillating crystal 
to accurately monitor the cycle time of the lubrication system to 
enable precision timed shutdown capability.   The magnet 
assembly and control housing mount directly to the divider valve to 
become an integral part of the lubrication system.   The DNFT 
operates on a field replaceable lithium battery.  If battery voltage 
drops below normal operating levels the DNFT goes into  alarm 
mode and the unit cannot be restarted.   LED models utilize an LED 
to indicate each cycle of the divider valve.   This enables the 
operator to easily set and monitor lubrication rates.   

Lubricant flow through the divider valve assembly forces the 
pistons to cycle back and forth causing a lateral movement of a 
magnet linked to the piston.   Movement is monitored by the 
microprocessor which resets the timer, lights the LED, and allows 
the unit to continue operation, this indicates one complete cycle 
of the lubrication system.   The microprocessor must receive this 
cycle in a predetermined time or a shutdown will occur.  The 
DNFT will automatically reset alarm circuit when normal 
operation of divider valve resumes.

WHITLOCK INSTRUMENT

1300 N. Texas

Odessa, TX 79761

432.3373412 Fax 432.335.5926

1.800.337.3412       www.noflo.com

186200

CE

Cl I; Div 1; Grps. A,B,C,D;T4

Cl I; Zone 1; Ex md IIC T4

          0344

KEMA 00ATEX1090 X Amb. -40° C...+80°C

R

US

R

US

Cl I; Zone 1; Ex md IIC T4

         II 2G EEx md IIC T5

186200

CE

Cl I; Div 1; Grps. A,B,C,D;T4

Cl I; Zone 1; Ex md IIC T4

          0344

KEMA 00ATEX1090 X Amb. -40° C...+80°C

R

US

R

US

Cl I; Zone 1; Ex md IIC T4

         II 2G EEx md IIC T5

Summary of Contents for DNFT-LED-PS

Page 1: ...ocessor and transistor components for detecting Slow Flow and No Flow of divider block lubrication systems The DNFT incorporates an oscillating crystal to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability The magnet assembly and control housing mount directly to the divider valve to become an integral part of the lubrication system The DNFT o...

Page 2: ...O ring or metal gasket F is in place on magnet housing C Screw magnet housing C into end of divider valve E Torque to 15 foot pounds max 4 Slide DNFT B all the way onto hex of magnet housing C Tighten set screws on hex of magnet housing Torque 25 inch pounds max 5 The LED on the DNFT indicates each divider valve cycle This enables operator to adjust the lubricator pump for correct cycle time and o...

Page 3: ...ure plugs Tighten all divider valve plugs Adjust DNFT To insure proper operation of the divider block lubrication system it is absolutely necessary that all tubing and components be filled with oil and free of air before start up Check system pressure to insure oil is flowing to divider valves If necessary install pressure gauge to monitor operation of lubrication system Check gauge to insure pump...

Page 4: ...tact DNFT BATTERY REPLACEMENT INSTRUCTIONS Directions for replacing the battery in the Digital No Flow Timer MAGNET H POLARIZED CONNECTOR CONTROL HOUSING B SPRING SPACER LED 22 AWG 18 LEADS 7 I O RING F 1 2 PIPE PLUG FIELD REPLACEABLE BATTERY P N 000505 MAGNET HOUSING C ALLEN HEAD SET SCREWS 2 A RED RED GREEN ORANGE ORANGE YELLOW 507LIT LED PS WI 4 06 05 01 R DIGITAL NO FLOW TIMER U S PAT NO 5 835...

Reviews: