Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you 

can smell the odorant in propane.

 Smoking can decrease your 

ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors in 

the area mask the gas odor. People may not smell the gas odor 

or their minds are on something else. Thinking about smelling a 

gas odor can make it easier to smell.

The odorant in LP-gas is colorless, and it can fade under some 

circumstances. 

For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants 

in LP-Gas also are subject to oxidation. This fading can occur if 

there is rust inside the storage tank or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto or into walls, 

masonry and other materials and fabrics in a room. That will take 

some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precautions 

which can protect both you and your family from an accident. 

Read them carefully now, then review them point by point 

with the members of your household. Someday when there 

may not be a minute to lose, everyone's safety will depend 

on knowing exactly what to do. If, after reading the following 

information, you feel you still need more information, please 

contact your gas supplier.

• 

Learn to recognize the odor of LP-gas. 

Your local LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

• 

If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

• 

Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the 

odor if there has been a leak of LP-Gas.

• 

Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been 

out of service for a time may develop internal rust which will 

cause odor fade. If such conditions are suspected to exist, 

a periodic sniff test of the gas is advisable. 

If you have any 

question about the gas odor, call your LP-gas dealer. A 

periodic sniff test of the LP-gas is a good safety measure 

under any condition.

• 

If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

• 

If you experience a complete "gas out," (the container is un-

der no vapor pressure), turn the tank valve off immediately. 

If the container valve is left on, the container may draw in 

some air through openings such as pilot light orifices. If this 

occurs, some new internal rusting could occur. If the valve is 

left open, then treat the container as a new tank. Always be 

sure your container is under vapor pressure by turning it off 

at the container before it goes completely empty or having it 

refilled before it is completely empty.

• 

Do  not  operate  electric  switches,  light  matches,  use  your 

phone. Do not do anything that could ignite the gas.

• 

Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

• 

Close all gas tank or cylinder supply valves.

• 

LP-Gas is heavier than air and may settle in low areas such 

as basements. When you have reason to suspect a gas leak, 

keep out of basements and other low areas. Stay out until 

firefighters declare them to be safe.

• 

Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department. Even though you may not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

• 

Finally, let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then 

check and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That's your signal to go into immediate action!

SAFETY INFORMATION FOR USERS OF LP-GAS

Summary of Contents for Vail

Page 1: ...mation in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life UNVENTED GAS FIREPLACE HYDRAULIC THERMOSTAT MODELS VFP24FP2 0 1 2 3 L N P 1 MILLIVOLT MODELS VFP24FP3 0 1 2 3 L N P 1 VFP24FP3 0 1 2 3 L10 N P 1 10 000 BTU UNIT INTERMITTANT PILOT MODELS VFP24FP7 0 1 2 3 L N P 1 Installer Leave this manual with the appliance ...

Page 2: ...VOLT CONTROL VALVE LIGHTING INSTRUCTIONS 14 HYDRAULIC THERMOSTAT MODELS LIGHTING INSTRUCTIONS 15 INTERMITTENT PILOT LIGHTING INSTRUCTIONS 16 LOG PLACEMENT 17 PILOT FLAME CHARACTERISTICS 18 20 MAIN BURNER AND THERMOSTAT OPERATION 20 MILLIVOLT WIRING 21 MILLIVOLT TROUBLESHOOTING 22 INTERMITTANT CONTROL SYSTEM OPERATING INSTRUCTIONS 23 INTERMITTANT CONTROL SYSTEM WIRING DIAGRAM 24 INTERMITTENT CONTRO...

Page 3: ...n10 000Btuperhourshallnotbeinstalledinabedroom or bathroom Duetohightemperatures theapplianceshouldbelocated out of traffic and away from furniture and draperies Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do no...

Page 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of newcylindersandtanks ispossible Therefore peopleshould be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tan...

Page 5: ...er or your gas company before changing spud orifice size WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with unvented room heater 3 Installer should show owner how to...

Page 6: ...here a Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall p...

Page 7: ...ctual amount of BTU Hr used BTU Hr maximum the space can support BTU Hr actual amount of BTU Hr used Example 25 600 BTU Hr maximum the space can support 38 000 BTU Hr actual amount of BTU Hr used WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tightconstruction provideadequatecombustionandventilationair ...

Page 8: ...immediately upstream of the gas supply connection to the appliance 2 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 3 The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test...

Page 9: ...ustible wall or material should not be less than 4 inches 2 Clearances from the top of the fireplace opening to the ceiling should not be less than 30 inches Mantel Clearances for Built in Installation Figure 5 Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 6 No greeting cards stockings or ornamentation of any type should be placed on or attached to...

Page 10: ...ling flange will secure the fireplace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four pre drilled screw holes on back of breastboard to secure breastboard to mantel sides with four Phillips wood screws 8 Place mantel top onto mantel 9 Installation of fireplace into mantel is completed Installation of Trim 1 Lower bottom louver 2 Remove screen from firepl...

Page 11: ... gas supply will enter on right hand side See Gas Supply Page 8 3 Insert fireplace into enclosure 4 Attach nailing flanges to framing with a screw or nail 5 Finished wall surface will be flush to the leading edge of fireplace top and sides 6 Installation of built in fireplace is completed Installation of Trim 1 Lower bottom louver 2 Remove screen from fireplace 3 Remove top louver from fireplace 4...

Page 12: ...o not allow fans to blow directly into fireplace Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burning will result During manufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but may produce smoke an...

Page 13: ...mbly 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF un less knob is pushed in slightly Do not force 6 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information abov...

Page 14: ... gas control knob slightly and turn clockwise to OFF 6 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety infor mation above If you do not smell gas go to the next step 7 Find pilot Follow metal tube from gas control The pilot is located next to the burner near the right side 8 Turn gas control knob counter clockwise to PI...

Page 15: ...knob slightly and turn clockwise to OFF Do not force 5 Wait ten minutes to clear out any gas Then smell for gas including near floor If you smell gas STOP Follow B in the safety information on other side If you do not smell gas Go to the Next step 6 Find pilot the pilot is located in front of rear log 7 Turn manual gas control knob counterclockwise to PILOT 8 Push in manual gas control knob all th...

Page 16: ...tructions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for ...

Page 17: ... Place boss on top right 5 log into right notch on rear 1 log Refer to Log Placement Figure for the following warning Warning Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this heater may result in property damage or personal injury LOG PLACEMENT Index No Part No Description 1 R6201 Rear Log 2 R6202 Left Front Log 3 R6203 Righ...

Page 18: ...flame and main burner flame meet Figures 16 17 and 18 show an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down Correct Pilot Flame Pattern THERMOCOUPLE LPG THERMOCOUPLE NATURAL THERMOPILE PILOT Millivolt Pilot Figure 13 PILOT THERMOCOUPLE NATURAL THERMOCOUPLE LPG H...

Page 19: ...llivolt Pilot Figure 16 PILOT THERMOCOUPLE LPG THERMOCOUPLE NATURAL Hydraulic Thermostat Pilot Figure 17 PILOT SENSOR IGNITOR Intermittant Pilot Figure 18 If pilot flame pattern is incorrect as shown in Figures 16 and 17 See Troubleshooting Page 22 If pilot flame pattern is incorrect as shown in Figure 18 See Troubleshooting pages 25 27 ...

Page 20: ...rom carpeting bedding materials etc Logs Be careful cleaning and handling logs so as not to damage them If logs break or fall apart in handling spray the broken pieces and fibers with water sweep up and discard MAIN BURNER AND THERMOSTAT OPERATION PILOT FLAME CHARACTERISTICS Cleaning and Pilot Maintenance Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen De...

Page 21: ... CETTE UNITE DOIT ETRE REMPLACE VOUS DEVEZ LE REMPLACER AVEC UN FIL ELECTRIQUE DE NUMERO 18 150 C DU L EQUIVALENT THERMOPILE GAS VALVE THERMOCOUPLE NATURAL OFF ON REMOTE OPTIONAL REMOTE CONTROL RECEIVER FACULTATIVE CONTROLE E DISTANCE DU RECEPTEUR OPTIONAL WALL SWITCH INTERRUPTEUR MURAL FACULTATIVE OPTIONAL THERMOSTAT FACULATIVE THERMOSTAT WIRING DIAGRAM GAS VALVE VALVE DE GAZ REMOTE OFF ON SWITCH...

Page 22: ...s not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough After ODS pilot lights keep control knob pressed in 30 seconds c Manual Shutoff valve not fully open Fully open manual shutoff valve d Thermocouple connection loose at control valve Hand ti...

Page 23: ...ty of the appliance 2 During the operating season or in power outage periods it is recommended that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as shown in Figure 23 Refer to page 8 for gas pressure requirements Note The gas control has a manual HI LO flame ...

Page 24: ...manufactured mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used CAUTION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alteration service or maintenance can cause prop...

Page 25: ...tions on page 16 and Wiring Diagram on page 24 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections between the wire harnesses and system components are prop...

Page 26: ...wire harness 4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 If pilot flow adjuster screw is not sealed Check if pilot flow adjust screw is set correctly in accordance with the appliance manufacturer instructions If necessary correct it 3 Replace pilot tube or ...

Page 27: ...e and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at the outlet pressure test point out according to the manufacturer s instruction If not in accordance replace the gas valve 1 Verify the electrical connections integrity and make sure they are in accor...

Page 28: ...8 ROCK WOOL NOT SHOWN P 251 COUPLING NAT ONLY VFP24FP30L and VFP24FP30L10 18 R3623 PILOT ASSEMBLY LPG 18 R3624 PILOT ASSEMBLY NAT 20 P 214 ORIFICE NAT 10 000 BTU 20 P 181 ORIFICE NAT 20 000 BTU 20 P 193 ORIFICE LPG 10 000 BTU 23 R3626 VALVE NAT 20 000 BTU 23 R3625 VALVE LPG 20 000 BTU 23 R9368 VALVE NAT 10 000 BTU 23 R9369 VALVE LPG 10 000 BTU 24 R2423 MALE ADAPTOR 25 25787 TUBING VALVE TO BURNER ...

Page 29: ...AT 19 R5675 AIR SHUTTER LP 20 P181 ORIFICE 43 VFP24FP70LN 20 P182 ORIFICE 55 VFP24FP70LP 21 P253 FITING ORIFICE ANGLED 22 29878 VALVE BRACKET 23 R11125 VALVE NAT 23 R11126 VALVE LPG 24 R6207 ELBOW 5 16 X 3 8 90 DEGREE 25 29821 TUBING ASSEMBLY INLET 26 29822 TUBING ASSEMBLY PILOT LP 26 29823 TUBING ASSEMBLY PILOT NAT 27 R7063 REGULATOR NAT ONLY 28 29824 TUBING ASSEMBLY PILOT 34 R2522 SWITCH ON OFF ...

Page 30: ...TS VIEW 1 3 2 4 4 5 6 7 8 9 9 10 11 14 15 18 16 17 21 20 19 22 5 12 13 12 23 26 25 31 30 29 33 32 23 24 25 29 32 34 33 26 27 28 21 20 19 18 17 16 22 36 26 27 25 24 23 35 34 28 26 VFP24FP2 Series VFP24FP3 Series VFP24FP7 Series ...

Page 31: ...iner bracket at the bottom of each side brick liner as illustrated NOTE Discard the long brick liner mounting brackets not used 6 Replace logs into burner assembly Refer to appropriate Installation Instructions and Owner s Manual 7 Attach screen assembly to fireplace 8 Installation of optional brick liner is completed VPP1A 22 For Unvented Gas Fireplace OPTIONAL BRICK LINER INSTALLATION INSTRUCTIO...

Page 32: ... left side of outer casing Motor with wiring will be to the inside of the outer casing blower chute will be facing upward See Figure 28 8 Push blower assembly against the left wall of the outer casing The magnets installed on the bottom of the bracket will hold it in place 9 Replace the two 10 x 1 2 screws on the left side of the firebox bottom 10 Attachtwoflagterminalsonwireharnesstofancontrolbra...

Page 33: ...l from black wire on motor 22 Attachonepinterminalfromblack hot wire smoothinsulation on cord set to one socket terminal from black wire on AUOT OFF ON 23 Attach one pin terminal from white wire on AUTO OFF ON to switch one socket terminal from white wire on motor 24 Attach green ground wires from wiring harness and cord set to interior back of outer casing with one 8 x 1 2 Phillips screw See Figu...

Page 34: ... the adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiringerrorscancauseimproperanddangerousoperation Verify proper operation after servicing Oiling Blower Motor The blower motor does not have oiling holes Do not attempt to oil the blower motor WARNING Unplugging of blower accessory will not stop the heater from cycling To turn off gas t...

Page 35: ...11301 BLOWER DIVERTER 4 R2099 CORD SET 5 R1410 STRAIN RELIEF BUSHING 6 25794 BLOWER BASE ASSEMBLY 7 R2804A BLOWER ASSEMBLY 8 R5804 WIRE HARNESS 9 R1404 SNAP BUSHING 10 11507 BLOWER SHIELD SIDE 11 25795 BLOWER SIDE FRONT 12 R2805 AUTO OFF ON SWITCH OPTIONAL BLOWER INSTALLATION INSTRUCTIONS cont 1 2 3 4 5 6 7 8 9 10 11 12 ...

Page 36: ... part number and description coincide 1 2 3 Index Number Part Number Description VFF24BR Brass Trim Kit 1 25974 Trim Top 2 25972 Trim Left 3 25973 Trim Right VFF24SS Stainless Steel Trim Kit 1 25982 Trim Top 2 25980 Trim Left 3 25981 Trim Right VFF24HP Hammered Pewter Trim Kit 1 25978 Trim Top 2 25976 Trim Left 3 25977 Trim Right ...

Page 37: ...treet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTRIBUTOR LIST Parts Not Under Warranty Parts can be ordered through your Service Person Dealer or a Master Parts Distributor See this page for the Master Parts Distribu tors list For best results the s...

Page 38: ...30411 0 0612 Page 38 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Page 39: ...30411 0 0612 Page 39 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Page 40: ...rt Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Reviews: