4.  Insert blower assembly into interior, bottom of firebox. Posi-

tion blower assembly so that you align the notch on back of 

blower assembly with the center screw on firebox back, then 

push the blower assembly against firebox back. The blower 

wheel must be centered with the back wall of the firebox. The 

magnets on the back and bottom of blower assembly will suf-

ficiently hold blower assembly in place.

Note: 

For field installation of blower assembly, it may be easier to 

remove rear cover panel to install blower. This eliminates 

the need to remove brick liner panels, but the blower would 

have  to  be  installed  prior  to  installing  the  firebox  into  a 

wall or chase. 

See Figure 28.

5.  Once the blower assembly is in position, locate the plug but-

ton in the top right rear corner of the firebox. Remove the 

plug with a standard screwdriver and discard plug.

6.  Next, find the fan control switch and wire assembly. Feed the 

wires through the hole at the top of the firebox, and secure the 

fan control switch with (2) #6 screws provided. 

See Figure 

29.

7.  The fan control wires will slide down between the firebox 

and outer wrap near the blower assembly. 

See Figure 29

.

8.  One fan control wire will have a 1/4” female terminal that 

must be attached to the open terminal on the blower motor. 

See Figure 32, Connection A.

9.  The other fan control wire has a 1/4” male terminal. Attach 

this terminal to the open terminal on the blower power cord. 

See Figure 32, Connection B

10.  Route the wires away from moving parts of the blower as-

sembly and retain wires together near the blower motor using 

the plastic purse clip provided.

11.  To  complete  the  installation,  plug  the  power  cord  into  the 

junction box receptacle at the right rear corner of the firebox 

outer wrap. 

See Figure 30.

12.  If room permits, the power cord can be located from the out-

side of the unit looking through the junction box access hole 

(with the junction box removed), then plug up the power cord 

before reinstalling the pre-wired junction box.

13.  Once all connections are made electrically, it is recommend-

ed that you test the blower fan control operation by turning 

on power to the blower (Caution: 110 Volt). Then apply heat 

to the fan control switch inside the firebox with a lighter or 

match  until  blower  is  activated.  Once  blower  is  activated, 

check for proper operation. Do not place hands near blower 

assembly or other wiring while power is on.

14.  Replace blower access plate and/or reinstall the brick liner 

panels if provided.

15.  This completes the installation of the optional FBB5 Blower 

kit accessory.

Note: 

This blower is equipped with a heat activated fan control 

switch. Blower will operate when the firebox warms up, 

and  will  turn  off  automatically  when  the  firebox  cools 

down.

REAR COVER PANEL MAY BE

REMOVED TO INSTALL BLOWER

REINSTALL COVER AFTER

BLOWER IS INSTALLED

Figure 28

FAN CONTROL

SWITCH LOCATION

FAN CONTROL WIRES

Figure 29

Figure 30

BLOWER POWER CORD

All manuals and user guides at all-guides.com

Summary of Contents for Breckenridge Deluxe VFD32FB0F-1

Page 1: ...or additional in formation consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL A VENT FREE LOG SET IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION GAS FIRED ANSI Z21 91 Ventless Fireplace Enclos...

Page 2: ...7 8 Gas Line Connection 8 Optional Fresh Air Kit Installation Instructions 9 11 Optional Single Speed Blower Installations Instructions 12 14 Junction Box Wiring Installation Instructions 15 Maintenance 15 Parts List 16 17 How to Order Repair Parts 17 Parts View 18 Accessories 19 20 TABLE OF CONTENTS All manuals and user guides at all guides com ...

Page 3: ...rt or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should show owner how to start a...

Page 4: ...ve at least 36 clearance from the front of the firebox Any vent free Gas Log Heater must be For use with approved ANSI Z21 11 2 unvented room heater Follow and complete the installation instructions of the gas log set and the requirements of this firebox Check all fittings for leaks before lighting the gas log set In planning the installation for the firebox it is necessary to determine where the unit...

Page 5: ...aces 1 A flat hard combustible or non combustible surface 2 A raised platform of combustible or non combustible material 3 Recessed into the floor as illustrated by Figure 4 flush face and Figure 5 louvered models 4 Supported under all 4 corners of the firebox so that contact is made on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installe...

Page 6: ...34 1 2 39 1 2 43 1 2 C 17 7 16 19 13 16 19 13 16 17 7 16 19 13 16 19 13 16 D 29 33 37 29 33 37 E 33 35 35 33 35 35 F 31 36 40 31 36 40 G 22 3 8 24 3 8 24 3 8 22 3 8 24 3 8 24 3 8 H 1 1 4 1 1 4 1 1 4 6 1 8 6 1 8 6 1 8 I 31 1 2 33 1 2 33 1 2 28 9 16 30 9 16 30 9 16 J 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 K 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 L 31 13 16 36 3 16 38 3 16 31 13 16 36 3 16 38 3 16 M 63 3 8...

Page 7: ...be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then slide the hood flange between the firebox top and face panel and re tighten the screws 2 Install one 1 screw at each end of the hood as shown C Louvered Models 1 If you have a louvered model remove upper louver 2 Place the t...

Page 8: ...listed on the plate is not your type of gas supply DO NOT INSTALL Contact your dealer for proper model Always use an external regulator for all LP fireboxes to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a ANSI Z21 11 2 vent free log set into t...

Page 9: ...he fireplace or firebox as desired It must be installed prior to or at the time of fireplace or firebox installation to framing The FreshAir kit must be installed prior to the installation of wall board or other finishing materials around the unit Tools needed Gloves Metal snips Vise Grip Nut Driver Standard Screwdriver Caution Sharp edges Air Door Installation for Vent Free Firebox Models VFD 32 36 42...

Page 10: ...AIR ROD OUTSIDE AIR ROD BRACKET Figure 20 OUTSIDE AIR ROD BRACKET OPEN FRESH AIR ROD CONTROL LEVER LEFT SIDE VIEW OF FIREBOX OPENING TOP CUTAWAY VIEW DAMPER ASSEMBLY OUTER CASING FRESH AIR ROD OUTSIDE AIR ROD BRACKET when rotated upward and can be locked open by pulling for ward into the notch at the top of the control lever bracket 10 To close simply disengage by letting the lever rotate down war...

Page 11: ... of the duct through the exterior wall cut out 4 From the outside of the building connect the duct to the collar on the outside air vent assembly with band clamp or screws to secure 5 Mate the outside rain cap hood over the air vent seal with caulk as necessary then secure with screws provided to the exterior wall surface See Figure 22 and 23 6 Figure 24 illustrates the various options for install...

Page 12: ...assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 25 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY AND STATE BUILDING CODES BEFORE MAKING THE ELECTRI CAL CONNECTION MAKE SURE ...

Page 13: ... to the open terminal on the blower power cord See Figure 32 Connection B 10 Route the wires away from moving parts of the blower as sembly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 30 12 If room permits the po...

Page 14: ...emove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn clockwise to OFF Do not force To turn off gas on direct ignition model turn gas line valve to OFF 1 FBB5 BLOWER ASSEMBLY COMPLETE 2 R8199 FAN CONTROL SWITCH 1 2 A B 110 VOLT AC JUNCTION BOX WHITE FAN ...

Page 15: ...ed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to opposite side of receptacle The ground wire should be attached to the green neutral screw Install the receptacle into the junction box Attach cover plate Keep the control compartment logs and burner area surrounding the ...

Page 16: ...27 R8727 R8727 HOLE PLUG 17 19990 19990 19990 19990 19990 19990 BLOWER COVER PLATE ITEM PART NUMBER DESCRIPTION VFD36FB0L VFD36FB2DL VFD36FB2CL VFD36FB0F VFD36FB2DF VFD36FB2CF 1 17247 17247 17247 17247 17247 17247 TOP STANDOFF 2 18807 18807 18807 N A N A N A UPPER LOUVER 3 10554 10554 10554 10554 10554 10554 FRAMING BRACKET 4 18808 18808 18808 N A N A N A LOWER LOUVER 5 17162 17162 17162 17162 171...

Page 17: ...ntrol HOW TO ORDER REPAIR PARTS ITEM PART NUMBER DESCRIPTION VFD42FB0L VFD42FB2DL VFD42FB2CL VFD42FB0F VFD42FB2DF VFD42FB2CF 1 17247 17247 17247 17247 17247 17247 TOP STANDOFF 2 17187 17187 17187 N A N A N A UPPER LOUVER 3 10554 10554 10554 10554 10554 10554 FRAMING BRACKET 4 17188 17188 17188 N A N A N A LOWER LOUVER 5 17162 17162 17162 17162 17162 17162 JUNCTION BOX ASSEMBLY 6 R3492 R3492 R3492 ...

Page 18: ...23200 0 1206 Page 18 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 17 All manuals and user guides at all guides com ...

Page 19: ...SA Fresh Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits Standard 3 Piece Frame Kits Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Brass Stainless Steel or Hammered Pewter Contact dealer for all available optional frame kits Standard Hood Brass hood BR Stainless Steel SS Hammered Pewter HP Contact dealer for all available optional hood accessories ACCE...

Page 20: ... as optional kits in Brass Hammered Pewter and Stainless Steel finishes Contact dealer for all available optional trim accessories Decorative Door Kits Available as optional kits in Brass Hammered Pewter and Stainless Steel finishes Contact dealer for all available optional frame kit accessories Decorative Frame Kits Available as optional kits in Brass Hammered Pewter and Stainless Steel finishes Con...

Reviews: