Summary of Contents for PSD08

Page 1: ...Handling A Graco company 9 14 2022 Version 1 1 8 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 https wkfluidhandling com PSD08 Owner s Manual Manuals available online at wkfluidhandling com owners manuals Manual Part 18200 LM 0035 ...

Page 2: ......

Page 3: ...ion Advantages 8 3 3 System and Pump Environment 8 3 4 Control and Monitoring Connections 9 3 5 PSD 08 Installation Instructions 10 4 Pump Service Rebuilds 11 4 1 PSD Ordering instructions 11 4 2 PSD08 Rebuild Kit Ordering Instructions 12 4 3 Alternative Wet Kit Ordering Instructions 15 4 4 Tools 16 4 5 Torque Instructions 16 4 6 Disassembly instructions 17 4 7 Assembly Instructions 18 5 Accessori...

Page 4: ......

Page 5: ...the manufacturing process from raw materials to finished goods in our facility located in Kamas UT This allows us to rigorously manage our quality control process to ensure that our strict cleanliness procedures are always followed and that components are built under consistent methods and conditions for maximum reliability Our strict manufacturing process controls include assembling and testing W...

Page 6: ...M bottom 4 The passing of solids may shorten the life of a pump 5 Minimum startup pressure Max supply pressure STORAGE PSD pumps that are not put into operation upon delivery must be stored in an environment where they are protected from moisture extreme temperatures UV radiation vibration and should be kept clean White Knight recommends an environment of ambient temperature between 60 F 15 C and ...

Page 7: ...te Knight Fluid Handling A Graco company 9 14 2022 Version 1 1 8 Page 3 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 2 2 PSD08 Performance Curves Liquid Line Pressure PSI PSD08 Performance Curves Liquid Flow rate ...

Page 8: ... Page 4 Copyright 2022 White Knight Fluid Handling A Graco company 9 14 2022 Version 1 1 8 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 2 3 PSD08 Dimensional Drawing ...

Page 9: ... Copyright 2022 White Knight Fluid Handling A Graco company 9 14 2022 Version 1 1 8 Page 5 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 2 4 PSD08 Exploded View Drawing ...

Page 10: ... Page 6 Copyright 2022 White Knight Fluid Handling A Graco company 9 14 2022 Version 1 1 8 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 ...

Page 11: ...ht position Check valves within White Knight PSD pumps are actuated by gravity and or flow and perform optimally in the upright position Failure Potential It is possible that the diaphragm may fail In such a situation it is possible that chemical could enter the air side of the pump and may even escape through the muffler In such a situation the muffler media must be replaced and the air side purg...

Page 12: ...by passing solids wafer shards etc is coverable under warranty when your pump is used in conjunction with a White Knight Catcher pre pump filter Running Dry White Knight PSD pumps are capable of running dry without damage other than normal wear to the pump When a pump is run dry it cycles faster than normal accelerating the rate of normal wear Head Pressure Dead Head White Knight PSD pumps may be ...

Page 13: ...ions PUMP MONITORING Pump monitoring can be performed by solid state pressure switch monitoring This option is described on our website in the accessories section and is available for new orders and for retrofits in the field Pump Control Run mode and flow rate are two of the items which the CPT 1 can control monitor Pressure Switch Stroke Detection Conductivity Leak Detection ...

Page 14: ...e Line Shut off valve Air Dryer Filter Regulator Shut off valve Suction Line Vacuum Gauge Shut off valve Air supply port in pump body is NPT For BSPT use supplied adaptor 1 2 3 Shut off valve Flexible Connection Shut off valve Caution Closing suction line while pump is operating will cause irreversible damage to the pump Fix base plate to work station with four 3 8 or 10 mm bolts Bolts not include...

Page 15: ... Copyright 2022 White Knight Fluid Handling A Graco company 9 14 2022 Version 1 1 8 Page 11 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 4 Pump Service Rebuilds 4 1 PSD Ordering instructions ...

Page 16: ... RBPSD08UH NT 1 PSD08TE OT Alt Combined Rebuild Kit RBPSD08TE OT 2 PSD08TE ET Alt Combined Rebuild Kit RBPSD08TE ET 2 PSD08TE NT Alt Combined Rebuild Kit RBPSD08TE NT 2 PSD08UH OT Alt Combined Rebuild Kit RBPSD08UH OT 2 PSD08UH ET Alt Combined Rebuild Kit RBPSD08UH ET 2 PSD08UH NT Alt Combined Rebuild Kit RBPSD08UH NT 2 Contains all parts of RBPSD08 1 and applicable wet kit Contains all parts of R...

Page 17: ...08 16 24 10080 TE 217 O ring PTFE 217 4 10300 XX 0001 PTFE Lubricant Squeeze Tube 1 10080 EM 113 50 113 EPDM O ring Seal 2 10050 UH 0004 Shaft Glide Seal for WK Pump PSD08 2 Parts included in the RBPSD08TE ET Rebuild Kit Part Number Description Quantity 5144 SS 0001 Diaphragm Shaft for WK Pump PSD08 1 3200 EM 0001 Diaphragm for WK Pump PSD08 EPDM 2 10010 SS 0006 Stud Threaded 2 3300 SS 0004 Strike...

Page 18: ... 24 10080 TE 217 O ring PTFE 217 4 10300 XX 0001 PTFE Lubricant Squeeze Tube 1 10080 EM 113 50 113 EPDM O ring Seal 2 10050 UH 0004 Shaft Glide Seal for WK Pump PSD08 2 Parts included in the RBPSD08UH OT Rebuild Kit Part Number Description Quantity 5144 SS 0001 Diaphragm Shaft for WK Pump PSD08 1 3200 TE 0001 Diaphragm for WK Pump PSD08 PTFE 2 10010 SS 0006 Stud Threaded 2 3300 SS 0004 Strike Plat...

Page 19: ...re an alternative rebuild kit use the graphical ordering instructions shown below Air Motor Air Motors do not need to be removed from the pump for service However complete air motors with all components tested and certified are available from White Knight They can be removed and installed in the pump body as shown in the figure using the air motor pin wrench tool Rotate counter clockwise to remove...

Page 20: ...ctions Four pin wrench used to remove install the Sleeve Pilot Spool Assembly included with pump Hex is for use with a 19mm or socket drive 12100 PV 0030 Manifold Bolts Tie Bolts Tie bolts purple on both sides must be torqued before manifold bolts blue on top and bottom Torquing of tie bolts should be done in a crossing fashion as shown in image There is no particular order for torquing manifold b...

Page 21: ...uctions Remove top check valve parts following the same process described in step 3 Use hook to remove wearable surface placed below check assembly Use 10 mm socket to remove pump base feet and inlet manifold Remove bottom O ring and check valve parts Without scratching the inner bore use a hook to remove the check cages 1 2 3 4 5 6 8 10 7 Remove the two glide seals seated in the shaft cavity Then...

Page 22: ...ad one diaphragm to the shaft and push it through the shaft bore Align and thread the second diaphragm and strike plate onto shaft Make sure the diaphragms are snug on shaft Replace inlet manifold and bottom retainers using 10 mm socket Do not tighten Return to page 16 and follow torque instructions Return to page 16 and follow torque instructions before advancing to step 11 Taking care to not dam...

Page 23: ...uded with pump Required if pump is to be submerged Pump Catcher Inline options available Large through holes to avoid loading Filter may be removed without removing the Catcher from the pump or the line If a pump were damaged by passing solids while using the Catcher it would be repaired under warranty Control Monitoring Options Stroke Detection Solid State Pressure Switch SP1 Leak Detection Condu...

Page 24: ...guarantee the suitability of any pump component or subassembly for any particular or specific application White Knight Fluid Handling shall not be liable for any consequential damage or expense arising from the use or misuse of its products in any application Responsibility is limited solely to the replacement or repair of defective White Knight pumps components or subassemblies All options to reb...

Page 25: ... Copyright 2022 White Knight Fluid Handling A Graco company 9 14 2022 Version 1 1 8 Page 21 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 7 Certificate Declaration of Conformity ...

Page 26: ...company 9 14 2022 Version 1 1 8 187 E 670 S Kamas UT 84036 435 783 6040 888 796 2476 White Knight Support 187 E 670 S Kamas UT 84036 Phone 435 783 6040 Toll Free 888 796 2476 Fax 435 783 6128 support wkfluidhandling com https wkfluidhandling com support ...