Check loose connections or damage to loom
Re-assemble or replace the loom
3.3 The heating system does not work
YES
Check if the “cool” program is in operation
Re-test the appliance in a heating program
NO
YES
Check if terminal P4 is loose
Re-attach terminals
NO
YES
Check if the loom is damaged
Replace the loom harness
NO
YES
Check if the Inlet thermostat on the heater
Replace
the
heater
subassembly
assembly is damaged
3.4 The drum turns but the appliance fails to dry
Is the ambient temperature higher than 35°C
NO
YES
Check the correct program has been selected
Select the correct program
NO
YES
Check if the dryer is overloaded
The load placed in the drum must not exceed the
maximum load rating stated in the instruction book
NO
YES
Check that the filter is clean
Clean the filter
NO
YES
Is
the
heat
exchanger
blocked
Clean
the
heat
exchanger
NO
YES
Is the Inlet thermostat damaged or has the thermal
Reset the thermal cut-out if tripped. Replace the heater
cut-out
tripped
subassembly
if
damaged
NO
YES
Is
the
heater
damaged
Replace
the
heater
subassembly
NO
YES
Check the load moisture sensors
Clean and then check. If still faulty, replace.