3. FAULT FINDING
3.1 Lack of display on control panel
Check
if
power
is
NO
YES
getting
to
the
appliance
Check
fuse
for
continuity
Replace
fuse
YES
Switch off the appliance
NO
Check power cord and
YES
Replace the mains cable
Check for 230V between
loom harness for damage
or
loom harness as necessary
pins P0 on PCB
YES
YES
Replace the PCB
Check the RFI filter for damage
3.2 Drum does not turn but the control panel displays correctly
YES
Check if the belt is loose or damaged
Re-fit or replace belt
NO
YES
Check if the terminals of P2 are loose
Ensure that the terminals are connected correctly
NO
YES
Check the front support wheel for damage
Replace the front support wheel (including wheel shaft)
NO
YES
Check if the capacitor has correct value
Insert
or
replace
capacitor
and is connected to the loom
NO
YES
Check if the tension spring
Install or replace the tension spring
NO
YES
Check the motor for damage
Replace the motor
NO
YES
Check for blockage/binding when drum rotates
Check and remove blockage
NO
YES
Check for damage to the drum bearing
Replace the drum bearing assembly
NO
YES
Check any damage to door switch
Replace
the
door
switch
NO
YES