Functional characteristics
NTC sensor failure management
Freezer Compartment:
The following emergency procedure must be performed if the freezer temperature sensor became
unreliable:
Compressor, Compressor fan (1 minute delay since compressor starting) and Evaporator fan (3 minutes
delay since compressor starting) will be driven constantly till the emergency will recover.
No change will be implemented for refrigerator compartment algorithm and defrost operation.
The freezer probe is defect, if the resistance value is higher than 110 Kohm or lower than 500 ohm.
Refrigerator Compartment:
The following emergency procedure must be performed if the Refrigerator temperature sensor became
unreliable:
Damper and Evaporator fan shall cycle 15 minutes ON (Damper open and Evaporator run) and 30 minutes
OFF constantly till the emergency will recover.
Summary of Contents for WSE 2930 W
Page 14: ...Range 2012 Novelties 1 New IDI In Door Ice Sankyo ice maker ...
Page 45: ...Functional characteristics NTC senor in the freezer compartment ...
Page 86: ...Troubleshooting Documents Service Info WSF 7656 W 8586 462 79100 Whirlpool version ...
Page 89: ...Technical Data Main Board ...
Page 92: ...Technical Data Stepper Motor Dispenser assy ...
Page 93: ...Technical Data Dispenser paddle Switch TS 12M AHM B RS Rating 12V DC 50mA ...
Page 94: ...Technical Data Dispenser LED Supply voltage nominal 14 V DC 5 ...