background image

30" (76.2 cm) Slide-in Gas Range

PRODUCT MODEL NUMBERS

WEG730H0D          WEG760H0D

GAS SUPPLY REQUIREMENTS

Gas supply line:

Provide a gas supply line of 

3

4

" (1.9 cm) rigid pipe to the

range location. A smaller size pipe on longer runs may

result in insufficient gas supply. With LP gas, piping or

tubing size can be 

1

2

" (1.3 cm) minimum. Usually, LP gas

suppliers determine the size and materials used in the

system.

NOTE:

 Pipe-joint compounds that resist the action of LP

gas must be used. Do not use TEFLON

®†

 tape.

Flexible metal appliance connector: 

If local codes permit, a new CSA design-certified, 4 to

5 ft (122 to 152.4 cm) long, 

1

2

" (1.3 cm) or 

3

4

" (1.9 cm)

I.D., flexible metal appliance connector may be used for

connecting range to the gas supply line.

1

2

" (1.3 cm) male pipe thread is needed for connection

to the female pipe threads of the inlet to the appliance

pressure regulator.

Do not kink or damage the flexible metal tubing when

moving the range.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff

valve. This valve should be located in the same room but

external to the range opening, such as an adjacent cabinet.

It should be in a location that allows ease of opening and

closing. Do not block access to shutoff valve. The valve is

for turning on or shutting off gas to the range.

A.   Gas supply line

B.   Shutoff valve “open” position

C.   To range

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be 

used. The inlet pressure to the regulator should be as follows 

for proper operation:

Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP

LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet 

pressure.

PRODUCT DIMENSIONS

This manual covers several models. Your model may appear 

different from the models depicted. Dimensions given are 

maximum dimensions across all models.

A.   1 

3

16

" (3.0 cm) height from

      cooktop to top of vent

B.   29 

7

8

" (75.9 cm)

C.   Model/serial number plate

      (located behind the oven door on

      the top right-hand side of the

      oven frame)

D.   36" (91.4 cm) height to top of

      cooktop edge with leveling legs

      screwed all the way in*

E.   28 

5

16

" (71.9 cm) max.

      depth from front of console

      to back of range.

F.    28 

7

8

" (73.3 cm) max. depth

      from handle to back of

      range.

IMPORTANT: 

Range must be level after installation. Follow the 

instructions in the “Level Range” section. Using the cooktop as 

a reference for leveling the range is not recommended.

*Range can be raised approximately 1" (2.5 cm) by adjusting

the leveling legs.

Type of Gas 
Natural gas:

This range is factory set for use with Natural gas. See “Gas

Conversions” section. The model/serial rating plate located

behind the control panel has information on the types

of gas that can be used. If the types of gas listed do not

include the type of gas available, check with the local gas

supplier.

LP gas conversion:

Conversion must be done by a qualified service technician. No 

attempt shall be made to convert the appliance from the gas 

specified on the model/serial rating plate for use with a different 

gas without consulting the serving gas supplier. See “Gas 

Conversions” section. 

†®

TEFLON is a registered trademark of E.I. Du Pont De Nemours and 

Company.

Page 1 of 2

Ref. W10665256

E

0

8

/15

B

D

A

F

E

C

A

B

C

Reviews: