Summary of Contents for Coolerator CAW21D2A1

Page 1: ......

Page 2: ...not able to operate it properly l Is properly maintained l Also remove energy label and buy guide Use damp cloth to take off any glue residue Do not use a sharp instrument or any harsh or abrasive cleaners Energy SavingTips l Improve home insulation seal doors windows and close fireplace flue l Close blinds or drapes on sunny side of house add window awnings l Keep air filter clean Don t block air...

Page 3: ...uge Use copper wire only It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri cian OBSERVE NATIONAL ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES Electrical Requirements A 115 volt 103 5 min 126 5 max 60 hertz AC only 15 ampere fused electrical supply is required time delay fuse or time del...

Page 4: ... and not be interrupted by plastic rubber or other electrically insulating connectors including water meter or pump without adding a jumper wire at these con nections ELECTRICAL REQUIREMENTS For 230 volt and 230 208 volt models with serial plate amperes up through 12 0 Refer to Chart B for specific wiring and receptacle information to be used OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES Do not...

Page 5: ...ing and receptacle information to be used OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES Do not under any circumstances remove the power supply cord ground plug ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A separate electrical supply is required on a separately fused circuit Do not fuse ground neutral See Chart C for receptacle voltage require ments proper fuse size wire and wiring connectio...

Page 6: ...rm with rating of the appliance Do not use an extension cord PLUG AND RECEPTACLE DATA RECEPTACLE VOLTAGE 60 HERTZ AC IN ALL INSTANCES SERIAL PLATE AMPERES RECEPTACLE _ MODEL WITH SERIAL PLATE OF 230 VOLTS 207 MIN 253 MAX P through 1 MODEL WITH 24 0 SERIAL PLATE OF 2301209 VOLTS 197 6 MIN 253 MAX USE TIME DELAY FUSE OR TIME DELAY CIRCUIT BREAKER RATING IN AMPS MINIMUM RECEPTACLE WIRE SIZE SEE BELOW...

Page 7: ...tion follow INSTALLATION INSTRUCTION 2 on page 12 1l Unpack accessory parts see Figure 3 be fore installing your air conditioner A normal installation can be made with a screwdriver a drill saw small level pocket knife 7 16 socket wrench l 8 drill bit and tape measure WINDOW LOCK WE WIDE 4 SHEET 7 SHEET 3Wb METAL SCREWS METAL SCREWS SCREWS u 5 FLAT 6 NUTS 8X3 8 rlOX112 qloX3 4 WASHERS ROUND HEAD H...

Page 8: ...moving retaining screw save screw for reuse later Now slide unit out of cabinet by pulling out on handle on bottom see Figure 6 5 Attach seal strips to cabinet Place 3 8 wide self adhering seal strip on window side of bot tom flange Now starting at the lower corner of the cabinet apply 3 8 wide seal strips over the center line of the pre drilled holes for one of the side mounting angles over the c...

Page 9: ...M INSIDE ONE WINDOW CHANNEL TO INSIDE OF THE OTHER AND SUBTRACT 114 1 1 8 Apply seal strips and attach filler boards De termine which will be your left and right filler boards The holes on each board should align with the holes in the side mounting angles Each filler board should also extend about l 2 above the top edge of the air conditioner cabinet Now apply 3 8 wide seal strips on the room side...

Page 10: ...upports together with 3 4 bolts washers and nuts Tighten securely see Figure 14 PLAIN WASHER FASTEN BOLT SECURELY 13l Position support assemblies against bottom rail of cabinet and slide toward house allowing approximately one inch clearance between end of angle support and wall see Figure 15 Select proper sets of square holes in cabinet rails and fasten support assemblies to cabinet rails by usin...

Page 11: ...onditioner is installed where this Is undesirable you can direct the water to a more suitable spot by using some flashing or other similar means DRAIN CUP ASSEMBLY INSERT INTO 18l Insert air conditioner into cabinet Slide air conditioner only three fourths of the way into the cabinet Do not push against sharp fins and plastic parts Apply 5 8 thick seal strip onto bottom of base of air conditioner ...

Page 12: ...e of decorative molding you want to use around the room side of the cabi net Your choice affects the finish frame alignment with the inside wall When using a wood metal or plastic molding the finish frame should almost line up with the inside wall If the wall is plastered to the cabinet and no molding is used the finish frame must be set into the wall by l 2 see Figure 20 for frame construction or...

Page 13: ...de leveling Fill all spaces between cabinet and finish frame with insulation Drill holes in the cabinet and attach it securely to finish frame Use ten lO x 1 wood screws four screws for each side and two screws for the top not included Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and unit Insert air conditioner into cabinet Do not push against sharp...

Page 14: ...umber setting to less cooling You will need to experiment to find the setting which suits vou best 3T AND USE NDITIONER for Energy Saver models only 1l Choose a fan setting either AUTO FAN or NORM FAN 2l The AUTO FAN setting saves energy The fan will cycle on and off as the thermostat turns the compressor on and off This saves the cost of electrical energy that would be used to run the fan continu...

Page 15: ...IR Set fan control to FAN ONLY 3 To circulate room air Set fresh air and exhaust control to OFF Set fan control to FAN ONLY ChangingAir Direction The louvers in the grille area at the top of the air conditioner control the direction of the cooled air Cleaningand Caring For Your Air Conditioner Proper use and care of your air conditioner will help insure longer life and lower operating costs Follow...

Page 16: ...y Replace front panel Wipe control panel clean with a soft dry cloth Figure 27 1a 2l The filter is cleanable A clean filter helps remove dust lint and other particles from the air Check every two weeks to see if filter needs cleaning If the front panel of your unit looks like the one shown in Figure 26 remove filter from plastic front frame by removing elastic band which holds it in place see Figu...

Page 17: ...refully clean and hose out the base coils and condensate pans Clean at least once a year or more often if the condenser coils and pans collect dirt sand leaves insects or algae Also clean if you detect an odor from the air conditioner While the cabinet is open this is a good time to oil the fan motor Remove plastic film from motor and electrical parts Replace unit in cabinet NOTE It s a good idea ...

Page 18: ...exposure 4 From lhls point read down lo bottom of chart to determlne required Btulhr output Wrlle Ihe Bluihr figure I the space Indicated below 5 Btuihr from number 4 above 6 Locale your geographic area on unset map and multiply factor shown by flqure in number 5 7 6 If room air condltloner IS lnlended prlmarlly for night time cool no sublracl 30 from flaure I number 6 Subtract 36 Btu hr from figu...

Page 19: ...your appliance or if ser vice is necessary recommend a qualified service company in your area 3 If you need service 7ma l E FRANCHISED SERVICE Whirlpool has a nation wide net work of fran chaised TECH CARE service Companies TECH CARE service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate TECH CARE service in your a...

Page 20: ......