Summary of Contents for AS09

Page 1: ......

Page 2: ...eating operation with the remote controller Press any button when flashes Cooling Only is set If you don t press any button within 12 seconds the remote controller is preset as Heat Pump automatically If you want auto restart function let the appliance is energized hold down the Emergency button ON OFF on the indoor unit for over 5 seconds auto restart function is set with buzz sound air condition...

Page 3: ... pull or press the power supply cord lest the power supply cord be broken An electric shock or fire is probably caused by a broken power supply cord Never insert a stick or similar obstacle to the unit Since the fan rotates at high speed this may cause an injury Do not repair the appliance by yourself If this is done incorrectly it may cause an electric shock etc Turn off the appliance by remote c...

Page 4: ... Air Outlet Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Air Filter Remote Controller Connection Cord Pipes and Power Drain Hose Front Panel Emergency Panel Display Panel Note Condensate water drains at COOLING or DRY operation Identification of parts 3 Indoor unit Outdoor unit FA N MO DE TIM ER ON CLOCK TIM ER OFF SLEE P SW ING ON ON OF F OF F JE T SM AR T LOCK ...

Page 5: ... It lights up during the set time It lights up when compressor is running It is on during operation It flashes during defrosting Timer Indicator Compressor indicator Run Indicator Sleep Indicator UH series operating and display It lights up when unit is in sleep mode Temperature display Display actual room temperarure Display set temperature ...

Page 6: ...the buttons are locked and not available Press again to cancel it Used to set the current time Used to enter fuzzy logic operation directly regardless of the unit is on or off The appliance will be started when it is energized or will be stopped when it is in operation if you press this button Press this button to select the operation mode Used to set or cancel the timer operation Remote controlle...

Page 7: ...ner aim the remote controller to the signal receptor The remote controller will operate the air conditioner at a distance of up to 7m when pointing at signal receptor of indoor unit Choose Cooling Only Remote controller or Heat Pump Please refer to page 1 Preparation before use for details Signal receptor Remote controller Remote controller If the replacement is done within 1 minute the remote con...

Page 8: ...y 1 lower Press once to temperature setting by 1 raise Range of available set temperature HEATING COOLING DRY FAN unable to set unable to set Turning on SWING 6th sense TIMER ON TIMER OFF CLOCK SLEEP and Jet operation modes will be specified in the following pages Press button when the appliance receives the signal the RUN indicator of the indoor unit lights up Changing modes during operation some...

Page 9: ...when the louvers swing to a suitable angle as desired Horizontal airflow control with hands Turning the control rods of the horizontal adjustment louvers to change horizontal air flow as shown control rods of horizontal adjustment louvers Note The shape of the unit may look different from that of the air conditioner you have selected Do not turn the vertical adjustment louvers manually otherwise m...

Page 10: ...of unsuitable flow direction Indoor fan speed alternates among High Medium and Low each time this button is pressed Press it once the vertical adjustment louver swings to change vertical airflow direction Press it again swings stops For horizontal airflow direction please refer to the previous page for details Operation mode and temperature are determined by indoor temperature Note Temperature air...

Page 11: ...mode has been canceled When your desired time displayed on LCD press the TIMER ON button and confirm it A beep can be heard Note If you don t set the time in 10 seconds after you press TIMER ON button the remote controller will exit the TIMER ON mode automatically Note It is similar to set TIMER OFF you can make the appliance switch off automatically at your desired time The TIMER indicator on the...

Page 12: ... NOT available for cooling only air conditioner Jet mode is used to start or stop fast cooling Jet mode can be set when the appliance is in operation or energized Fast cooling operates at high fan speed changing the set temperature automatically to 18 In Jet mode you can set airflow direction or timer If you want to escape from Jet mode press any MODE FAN ON OFF or TEMPERATURE SETTING button the d...

Page 13: ... if the appliance is very dirty Never sprinkle water onto the indoor unit Reinstall and shut the front panel Reinstall and shut the front panel by pressing position b downward If the dirt is conspicuous wash it with a solution of detergent in lukewarm water After cleaning dry well in shade Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment Stop t...

Page 14: ...he outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbors Do not place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level 13 Protection Features of protector The protective device will work at following cases Restarting the unit at once after operation stops or changing mode during operation you need to wa...

Page 15: ...r device may be preventing unit to work The following cases may not always be a malfunction please check it before asking for service If strong interference from excessive static electricity discharge power supply voltage abnormality presents operation will be abnormal At this time disconnect from the power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will del...

Page 16: ...let distance from the wall should be over 500mm should be over 50 mm should be over 50mm should be over 2000mm should be over 250mm Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased 15 Installation instructions Installa...

Page 17: ...t subject to increasing operation noise Where there is not any blockage for air outlet Location for Installing Indoor Unit Where there is no obstacle near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page Where the air filte...

Page 18: ...leeve through the wall hole to keep the wall tidy and clean Drill a hole on the wall The hole should tilt a little downward toward outside Decide the position of hole for piping according to the location of mounting plate 2 Drill a Hole for Piping Keep the mounting plate horizontally with a horizontal ruler or dropping line Drill holes of 32mm in depth on the wall for fixing the plate Insert the p...

Page 19: ...th a piping fixer Thermal insulation wrapped with vinyl type Small pipe Large pipe Thermal insulation tube Power cord 1 for heat pump Power cord Defrost cable for heat pump Drain hose prepared by user A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Base Piping fixer Piping fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe ...

Page 20: ...g refer to the circuit diagram posted on the inside of the access door 2 Comfirm that the cable thickness is as specified in the power source specification See the cable specification table below 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist area The figures in this manual are based on...

Page 21: ...of the outdoor unit and the terminal No are the same as those of the indoor unit Outdoor unit Power connecting cord Blue Blue Yellow Green Yellow Green Brown Brown N N 1L 1L COOLING ONLY Terminal Terminal 20 9K 12K 18K Model For above models the power supply are connected from indoor unit ...

Page 22: ...e condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units evacuate air and moisture from refrigerant cycle using a vacuum pump as shown b...

Page 23: ... for power consumption details If the supply cord is damaged it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard In order to ensure the suitability of the equipment for connection the user should consult with the supply authority if necessary that the service current capacity at the interface point is sufficient for the equipment Th...