Summary of Contents for ACS072XG

Page 1: ...ner 7 Operating Your Air Conditioner 12 Caring For Your Air Conditioner 14 Troubleshooting 17 Requesting Assistance Or Service 18 Warranty 20 1 800 253 1301 Call Our Consumer Assistance Center with questions or comments or visit our website at www whirlDool com SLIDER CASEMENT WINDOW AIR CONDITIONERS PART NO 23 ll 2112N 001 789771 MODELS ACS072XG ACS102XG s 3 ...

Page 2: ... s information Whenever you call to request service on Model Number your appliance you need to know your Serial Number complete model number and serial number You can find this information on the model Purchase Date and serial number label see diagram on Dealer Name page 4 for location of label Please also record the ourchase date of Dealer Address your appliance and your dealer s name address and...

Page 3: ... move or l Do not remove ground prong install air conditioner l Do not use an adapter Do not drink water collected inside the l Do not use an extension cord cabinet l Unplug air conditioner before servicing SAVE THESE INSTRUCTIONS Help us help you Please l Install your air conditioner in a window that l Use the air conditioner only to do what a will hold the weight and secure the air window air co...

Page 4: ... located and what they look like To help you find information on specific parts or features quickly page references are included Removable air filter behind panel Model and serial number plate ind air louvers Removable front panel P 14 Control Panel EXHAUST CONTROL FAN CONTROL 1HERMOSTAT ii cjg L Q Exhaust vent control I Fan control Thermostat control 4 ...

Page 5: ... an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Observe all local codes and ordinances Do not under any circumstances remove the power supply cord ground prong NOTE If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate and not interrupted...

Page 6: ...cuit breaker required It is required that a separate circuit serving only this air conditioner be provided Electrical connection Electrical ground is required on this air conditioner Recommended ground method For your personal safety this air conditioner must be grounded This air conditioner is equipped with a power supply cord having a 3 prong ground plug To minimize possible shock hazard the cor...

Page 7: ...tructed opening above the mounting platform In some cases due to a variety of stop and track arrangements the above dimensions may vary slightly 2 Choose the installation site The window frame and side of the structure must be able to support at least 110 Ibs of weight 3 Choose the proper window location Choose a window that will allow the cooled air to flow freely and directly into the room s you...

Page 8: ...ted later Loosely attach the support angle to the bottom Of the SUDDOrt DkItfOrrt7 USinCl two 7 l 6 long hi screws flat washers and nuts 3 E long self tapping 7A 6 long screws Self tapping screw Place the support platform assembly against the lower window track and firmly against the vertical edge of the window trame Attach the support platform assembly to the window stool using two self tapping s...

Page 9: ...ing if necessary Do not drill a hole in the bottom pan The air conditioner is designed to operate with approximately W of water in the bottom pan window frame Top retainer Filler panel 10 Cut two pieces of adhesive back foam Step 17 Step 17 seal equal to the height of the Foam seal window opening Remove backing and apply to the vertical inside edges of the window frame and sliding sash Foam that w...

Page 10: ...st the side of the air conditioner cabinet Cut remaining adhesive back foam seal equal to the width of the window opening Remove the backing and apply to the top inside edge of the window frame Install the speed clips on the top and bottom inside edges of the window to provide locking Insert the appropriate plastic foam seal between the inside window sash and the outside window Place the top retai...

Page 11: ...rior wall of the building and secure or remove completely where possible Do not block air circulation to the outside louvers 3 A filler panel will be required at the side of the air conditioner when installed in windows having width greater than 15 W Filler panel should be made from 3 4 thick wood securely anchored to one side of the opening so that a 15 lR wide opening is provided The filler pane...

Page 12: ...FAN for minimum room air circulation when no cooling is desired 3 Turn the THERMOSTAT Control to the desired setting You can adjust the air conditioner s cooling performance by turning the THERMOSTAT Control clockwise for more cooling or counterclockwise for less cooling You will need to experiment to find the setting which suits you best 4 To turn the air conditioner off or in the event of a powe...

Page 13: ...oner is cooling frost may form on the coils behind the front panel This will block the airflow into the room To defrost the coils l Set the FAN CONTROL to the OFF setting and allow the ice to melt then resume normal operation To prevent frost build up 1 Set the FAN CONTROL to the desired COOL setting FAN CONTROL 2 Set THERMOSTAT Control to the middle setting 3 Make sure all louvers open are Do not...

Page 14: ...with warm water mild soap or detergent and a soft cloth Rinse and dry thoroughly 6 Wipe control panel clean with a soft dry cloth 7 Replace air filter 8 Replace the front panel 9 Plug in air conditioner or reconnect power Frorh panel Cleaning the air filter A clean filter helps remove dust lint and other particles from the air Check every two weeks to see if filter needs cleaning 1 Unplug air cond...

Page 15: ... platform 3 Remove the front panel See page 14 4 Remove the screws from the top and sides of the cabinet and then remove the cabinet 5 Wrap the motor electrical control box and compressor terminal box in plastic film to make sure no water or other liquid gets inside Water or other liquids could damage the insulation and cause serious mechanical problems 6 Clean and hose out the base coils and cond...

Page 16: ...ng area Saving energy You can help save energy by following the tips below l Improve your home s insulation Seal all doors and windows Close the fireplace flue l Close all blinds and drapes on sunny sides of the house Add window awnings l Keep the air filter clean l Do not block the airflow with drapes or furniture l Ventilate the attic High temperatures in the attic add to the air conditioner s c...

Page 17: ... OFF Is the THERMOSTAT Control set correctly Has the local power failed Air conditioner blows fuse or trips circuit breaker Is time delay fuse being used Is an extension cord being used Do not use an extension cord with this or any other appliance Are you waiting three minutes before trying to restart the air conditioner Air conditioner turns on and off OR does not cool the Is the air filter clean...

Page 18: ...ce anywhere in the United States To locate the authorized Whirlpool service company in your area call our Consumer Assistance Center telephone number see Step 1 or look in your telephone directory Yellow Pages under APPLIANCE HOUSEHOLD WASHING MACHINES MAJOR SERVICE REPAIR DRYERS SERVICE REPAIR See Whlrlpoal Appliances or See Whirlpool Appliances or Authorized Whirlpool Serwce Authorized Whirlpool...

Page 19: ...ting 18 CLEANING Front panel 14 Air filter 14 ELECTRICAL REQUIREMENTS 56 ENERGY Saving 16 INSTALLATION Tips 7 Sliding window 8 9 10 Casement window l 1 Wood sliding wood casement window 11 MAINTENANCE Annual performing 15 OPERATING YOUR AIR CONDITIONER 12 13 PARTS AND FEATURES 4 SAFETY 3 SERVICE Parts 18 Requesting 18 SOUNDS 16 TROUBLESHOOTING 17 WARRANTY 20 19 ...

Page 20: ...an overhead or other inaccessible location or not installed in accordance with published installation instructions E Repairs to parts or systems resulting from unauthorized modifications made to the air conditioner Service under the full warranties must be provided by an authorized Whirlpool service company WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some stat...