background image

Summary of Contents for ACE184XM0

Page 1: ...3 AIRCONDITIONER Ovens Compactors Room Air Conditioners Dehumidifiers Automatic Washers Clothes Dryers Freezers Refrigerator Freezers Ice Makers Dishw ...

Page 2: ...l Also remove energy label and buy guide Use damp cloth to take off any glue residue Do not use a sharp instrument or any harsh or abrasive cleaners Energy SavingTips l Improve home insulation seal doors windows and close fireplace flue l Close blinds or drapes on sunny side of house add window awnings l Keep air filter clean Don t block air flow with drapes or furniture l Ventilate attic high tem...

Page 3: ...pper wire only It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri cian OBSERVE NATIONAL ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES Electrical Requirements A 115 volt 103 5 min 126 5 max 60 hertz AC only 15 ampere fused electrical supply is required time delay fuse or time delay circuit...

Page 4: ...PE _ EYELE COLD WATER PIPE ADiPTER GROUND PRONG RECEPTACLE POWER SUPPLY CORD Cold water pipe must have metal continuity to electrical ground and not be interrupted by plastic rubber or other electrically insulating connectors including water meter or pump without adding a jumper wire at these con nections ELECTRICAL REQUIREMENTS I For 230 volt and 230 208 volt models with serial plate amperes up t...

Page 5: ...h serial plate amperes up through 16 0 Refer to Chart C for specific wiring and recep tacle information to be used OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES Do not under any circumstances remove the power supply cord ground plug ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A three wire single phase 60 hertz AC only electrical supply is required A separate electrical supply is required on...

Page 6: ...rical supply is required on a separately fused circuit Do not fuse ground neutral See Chart D for receptacle voltage require men ts proper fuse size wire and wiring connections which must conform with rating of the appliance Do not use an extension cord PLUG AND RECEPTACLE SERIAL PLATE OF BRANCH RECEPTACLE WIRING RECEPTACLE WIRING should be at least as large as size shown on electrical Chart D Use...

Page 7: ...AIN SPOUT USED ON o MODELS WITH DRAIN CUP AND WEATHER HOLE IN SEAL USED REAR ON 18 3 4 CABINET RAIL HIGH CABINETS ONLY SEAL STRIP x 1 t Some Models 2l Pick the right wall First decide what room s you want to cool Then choose a wall that will allow the air conditioned air to flow freely and directly into the room s you want cooled Remember it s difficult to move air around corners Choose a location...

Page 8: ...vers and adjoining wall allows for proper airflow into air conditioner F FIANGE ON BolToM OF CABINET 5l Construct finish frame Apply creosote or something equal to the outside exposed surface 6 Install the finish frame in the wall opening Square and level frame and nail it securely to the studs 7l Remove front panel by pushing top down and out This protects the panel from damage and makes the air ...

Page 9: ...shing as needed to guide water Note the type of drain parts you have Insert drain cup according to instructions in Figure 8 Figure 8 PLACE PLASTIC DRAIN INTO HOLE IN REAR OF CABINET WITH SPOUT DOWN PLACE DRAIN CUP INTO METAL I I BRACKET AND INSERT INTO CABINET RAIL SLOTS TYPE 1 1 TYPE 2 Figure 9 13 If you received one adhesive backed seal strip l 4 x l 2 remove paper backing from seal and install ...

Page 10: ...d air movement with heat HI HEATfor maximum air movement with heat 3l Turn thermostat control to Number 6 mid setting You can adjust the air conditioner s performance by resetting the thermostat control to a higher number for maximum cooling Lower the number setting for maximum heating You will need to experiment to find the settings which suit you best When lowering the thermostat control setting...

Page 11: ...Y FRESH AIR FAN ONLY ChangingAir Direction The louvers in the grille area at the top of the air conditioner control the direction of the cooled air 1l Move the tabs at the bottom of the grille to the right left or straight ahead Simply move the tabs in the direction you want the air to go see Figure 13 2 On most models the louvers can only be adjusted left or right The front set is fixed and direc...

Page 12: ...ve the front panel from unit when cleaning Press down at top edge of the front as shown in Figure 14 2l When the front moves away from top of cabinet pull top of front toward you 3l Lift up and away from the bottom spring clips Figure 14 10 2a 30 The filter is cleanable A clean filter helps remove dust lint and other particles from the air Check every two weeks to see if filter needs cleaning Remo...

Page 13: ...y clean and hose out the base coils and condensate pans Clean at least once a year or more often if the condenser coils and pans collect dirt sand leaves insects or algae Also clean if you detect an odor from the air conditioner While the cabinet is open this is a good time to oil the fan motor 3l Remove plastic film from motor and electrical parts 4l Replace unit in cabinet NOTE It s a good idea ...

Page 14: ...ore westerly exposure 4 From this point read down to bottom of charl to determlne required Btulhr oulpul Write the Btulhr figure in the space indicated below 5 Btu hr from number 4 above 6 Locate your geographic area on Inset map and mulhply faclor shown by hqure m number 5 7 If room air conditioner IS Intended prrmarlly for nlghl time coohna subtract 30 lfrom fiaure In number 6 6 __ Subtract 3d B...

Page 15: ...m your appliance or if service is necessary recommend a qualified service company in your area 3 If you need service Whirlpool has a nation wide network of franchised TECH CARE service Companies TECH CARE service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate TECH CARE service in your area Call our COOL LINE servic...

Page 16: ...conditiiner caused by accident misuse fire flood wts of God or use of products not approved by Whirlpool D The removal and reinstaktiof of the air conditioner if it is installed in an overhead or other inaccessible location or not installed in accordance with publi install km instructions Service under the full warranties must be provided by a franchised TECH CARE service company WHIRLPOOL CORPORA...

Reviews: