3
Parts Supplied
■
hooked bracket
■
plastic clip
■
4 foam pads
■
4 pan head screws
Tools Needed
Gather the required tools before starting the installation. Read and
follow the instructions provided with any tool listed here.
■
phillips screwdriver
■
1" adjustable wrench
■
level
■
bucket
■
pliers or slip-joint pliers (for drain and inlet hoses)
Location Requirements
Recessed Area and Closet Installation Instructions
IMPORTANT:
The stacked washer/dryer can be installed in an
enclosure. Check the locations of the water supply faucets,
grounded electrical outlets, and gas supply line connection (gas
dryer only). Depending on your application, longer washer fill
hoses, longer electric power supply cords and a longer flexible
stainless steel gas connector line than supplied with the
washer/dryer may be needed.
48 sq. in.*
(310 sq. cm)
24 sq. in.*
(155 sq. cm)
3" (7.6 cm)
6"
(15.2 cm)
72"
(182.9 cm)
27"
(68.6 cm)
3" (7.6 cm)
1" (2.5 cm)
See washer/dryer
dimensions
5-1/4"**
(13.3 cm)
* Min. top and bottom air openings for closet door.
** External exhaust elbow requires additional space.
*** Wall, door and floor molding may require additional spacing.
1"***
(2.5 cm)
1"***
(2.5 cm)
If the water supply faucets, electrical outlets, gas supply line or
power cord need modification, have a qualified plumber,
electrician or gas technician make the changes.
Mobile Home – Additional Installation Requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require special parts (listed following),
which are available for purchase from your local dealer or service
center. For further information, please call 1-800-4-MY-HOME
®
(1-800-469-4663).
Stacked washers and dryers must be securely fastened to the
floor.
Parts needed:
■
Mobile Home Installation Kit, Part Number 346764, needs to
be purchased to accomplish this. Order two kits to enable
you to secure both the front and the back of the unit to
the floor.
■
Metal exhaust system hardware.
Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby window)
should be at least twice as large as the dryer exhaust opening.
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
INSTALLATION REQUIREMENTS
Summary of Contents for 8572553A