Front Loading Washer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

DRAIN SYSTEM OPTIONS

WFW8500S

Electrical:

120-volt, 60 Hz, AC-only, 

15- or 20-amp, fused electrical supply. A time-
delay fuse or circuit breaker and separate circuit is
recommended.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 8540321

06-26-06

50

¹⁄₄

"

(127.6 cm)

27"

(68.6 cm)

36"

(91.4 cm)

30

¹⁄₂

"

(77.5 cm)

UNDERCOUNTER INSTALLATION

Washer on Pedestal

Dimensions shown are the recommended spacing.

Standpipe drain system - wall or floor (view A & B)

The standpipe drain requires a minimum diameter standpipe of 2

(5 cm). The

minimum carry-away capacity can be no less than 17 gal. (64 L) per minute.

The top of the standpipe must be at least 30

(76.2 cm) high and no higher than

96 in. (2.4 m) from the bottom of 
the washer.

Laundry tub drain system (view A)

The laundry tub needs a minimum
20 gal. (76 L) capacity. The top of
the laundry tub must be at least 
30

(76.2 cm) above the floor.

Floor drain system (view B)

The floor drain system requires a siphon break
that may be purchased separately. 

The siphon break must be a minimum of 28

(71 cm) from the bottom of the washer.
Additional hoses might be needed.

Stacked Washer and Dryer

Recommended installation spacing for 
cabinet installation

For cabinet installation, with a door, the minimum
ventilation openings in the top are required.

RECESSED AREA AND CLOSET INSTALLATIONS

For closet installation, with a door, the minimum ventilation
openings in the top and bottom of the door are required (view 2).
Louvered doors with equivalent air ventilation openings in the top
and bottom are acceptable.

A. Side view - closet or confined area
B. Closet door with vents 

     48"
(122 cm)

A

B

3"

(7.6 cm)

3"

(7.6 cm)

  1"

(2.5 cm)

4"

(10.2 cm)

  30

¹⁄₂

"

(77.5 cm)

48 in.

2

(310 cm

2

)

24 in.

2

(155 cm

2

)

1"

(2.5 cm)

30

¹⁄₂

"

(77.5 cm)

1"

(2.5 cm)

1"

(2.5 cm)

27"

(68.6 cm)

4"

(10.2 cm)

38" min.

(96.5 cm)

7" (17.8 cm)

9"
(22.9 cm)

7" (17.8 cm)

4"

(10.2 cm)

31

¹⁄₂

"

(80.0 cm)

27"

(68.6 cm)

1"

(2.5 cm)

1"

(2.5 cm)

1"

(2.5 cm)

1"

(2.5 cm)

1"

(2.5 cm)

36" min.

(91.4 cm)

27"

(68.6 cm)

2" (5 cm)

48"

2

 *

(310 cm

2

)

3" (7.6 cm)

3" (7.6 cm)

1" (2.5 cm)

24"

2

 *

(155 cm

2

)

12" (30.5 cm)

72"

(182.9 cm) 

27"

(68.6 cm)

  5 

¹⁄₄

"**

(13.3 cm)

1"***

(2.5 cm)

1"***

(2.5 cm)

*Min. top and

bottom air
openings for 
closet door.

**External exhaust

elbow requires
additional space.

***Wall, door and

floor molding may
require additional
spacing.

Reviews: