background image

Summary of Contents for 3QACM07XD2

Page 1: ...uctions Parts and Features Operating Your Air Conditioner Personalizing the Front Panel Caring for Your Air Conditioner Installing Your Air Conditioner Troubleshooting Obtaining Service ROOM AIR CONDITIONERS 2 3 4 5 7 a 10 14 14 Part No 1161126 ...

Page 2: ...omplete this section If you ever have a question concerning this appliance or if you need service first see Obtaining Service on page 14 If service is required you will need to know your appliance s complete model and serial number You can find this information on the model and serial number label see diagram on page 4 For your convenience we included a place below for you to record these numbers ...

Page 3: ... THE VICINITY OF THIS OR ANY OTHER APPLIANCE THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION SAVE THESE INSTRUCTIONS Consumer responsibilities Please l The steps on pages 1O l 3 must be performed by a qualified installer l Be sure the air conditioner is the correct voltage and size for the area you want to cool l Be sure the air conditioner is installed in accordance with all national electrical c...

Page 4: ...come familiar with where the parts and features are located and what they look like Air conditioner Outside air intake Exhaust door louvers control Air output louvers Protective plastic cover for Model and serw number label Control panel Control panel Inside air intake Slide out air filter door louvers handle 4 ...

Page 5: ...each cycle and how to operate it Turning the air conditioner on off To turn the air conditioner on Set the POWER Switch to ON To turn the air conditioner off Set the POWER Switch to OFF 1 IMPORTANT After ON wait approximately 3 minutes before 1 turning it back on If you don t wait 3 OFF minutes the air conditioner will try to start but turn itself off POWER Modifying the fan speed Use the FAN SPEE...

Page 6: ...he room air without cooling it However if the room temperature rises above 32 C 9O F the compressor will turn on and cool the room Modifying the air direction The air output louvers at the top of the air conditioner s front panel control the direc tion of the cooled air The louvers may be adjusted left right up or down Using the exhaust door The exhaust door allows the air conditioner to draw stal...

Page 7: ...r fabric pictures etc in the open area and replace the protective cover Removing the protective cover 1 Place the flat edge of a screwdriver into the 1 mm gap between the protective cover and the front panel 2 Carefully pry off the protective cover U Replacing the protective cover 1 Insert tabs on one side of the protective cover into the tabs in the corresponding side of the front panel 2 Snap th...

Page 8: ...rized Whirlpool service company for annual service Caring for the control panel l Wipe clean with a soft damp cloth Make sure the cloth is not dripping wet The control panel door If the control panel door pops out of place it pops back into place easily 1 Place the left door pin into the hole on the left side of the door opening 2 Flex the door slightly 3 Snap the right door pin into place Caring ...

Page 9: ...g a vacuum cleaner OR If it is very dirty wash the filter with warm water and a mild detergent Allow filter to air dry completely before replacing it 4 Slide filter up into the slot until filter is completely fitted NOTE You may need to clean the air filter more often if it is subjected to heavy dust dirt etc Performing annual coil cleaning The coils in your air conditioner need to be Contact an a...

Page 10: ...Free movement of air to the air intake louvers inside and outside The power supply cord can be fed through either side of the front panel Electrical outlet must be available within reach of the power supply cord DO NOT use an extension cord Cabinet dimensions The cabinet dimensions are as follows Width 470 mm Height 350 mm Depth with front panel 600 mm Clearance l Keep outside air intake louvers c...

Page 11: ... Your air conditioner is equipped with a power supply cord containing a 3 prong grounding plug To minimize possible electrical shock hazard the power supply cord must be plugged into a mating 3 prong grounding type wall receptacle which is grounded in accordance with all applicable codes If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer t...

Page 12: ...ew 1 and disconnect the green and yellow grounding wire 3 Remove the rear shipping screws 2 Install the drain plug and drain cup accessory parts to rear of cabinet Slide drain cup down into rear support between grooves in cup NOTE Attach drain plug and drain cup assemblies and attach hose before sliding unit into cabinet Install asket Screws Install Drain Drain cup PlW 6 Fix the cabinet to the sup...

Page 13: ...t Failure to do so will result in electrical shock Remove slide out filter from front panel Replace the front panel Inset t tabs into slots on the top flange of the cabinet Rotate the front panel downward until it fits snugly between cabinet side flanges Secure front panel with 2 round head screws accessory parts Replace slide out air filter NOTE Make sure the Exhaust Door Control lever is between...

Page 14: ...or trips circuit Make sure an extension cord is not being used breakers Make sure unit is plugged into a live circuit with proper voltage Wait at least 3 minutes after turning unit off before trying to restart 1 Remote control Replace batteries If the remote control still doesn t work call your doesn t work authorized service company Unit stops starts Deluxe Remote Control models only Check if Del...

Reviews: