background image

754764-100 Rev. A

1

THANK  YOU...

for selecting an Eljer bathing product. Your new bath is shipped to you after careful inspection. The whirlpool 
version is completely assembled with pump and circulatory system piping. All you need to finish the installation 
are your selected fittings, electrical connections and support bedding material.

To ensure maximum performance and pleasure from this product, please follow the instructions and cautions. 

© Eljer 2011
All product names listed herein are trademarks of Eljer unless otherwise noted.

For questions or service issues, please call Technical Support 1-(800)-442-1902.
Please do not contact or return product to the store.

MODEL NUMBERS

015-0005, 015-0015, 015-0026, 

015-0066, 015-0076, 015-0077, 

015-0305, 015-0309

PREMIERE WHIRLPOOL

INSTALLATION AND 

OPERATION MANUAL

Summary of Contents for 015-0005

Page 1: ...ions and support bedding material To ensure maximum performance and pleasure from this product please follow the instructions and cautions Eljer 2011 All product names listed herein are trademarks of Eljer unless otherwise noted For questions or service issues please call Technical Support 1 800 442 1902 Please do not contact or return product to the store MODEL NUMBERS 015 0005 015 0015 015 0026 ...

Page 2: ...ation Clean Up Instructions Page 4 Typical Flange Under Deck Mounting Instructions Page 6 General Specifications for Whirlpools Page 7 Roughing in References for All Model Series Pages 8 10 Electrical Installation Instructions Page 11 Total Massage Whirlpools Page 12 Operating Instructions Page 13 Cleaning and Maintenance Page 14 Warranty Page 15 ...

Page 3: ...scribed in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power shoul...

Page 4: ...ly so the rim of the bath contacts the stringer or pier but supports no weight Provisions must be made in all installations for an access opening for servicing the bath pump Unless an access opening of at least 12 x 24 305mm x 610mm is provided warranty service will not be performed It is strongly recommended that an additional opening be provided for access to drain components Each bath has a nom...

Page 5: ... the deck of the bath 3 Install drain components to the whirlpool following the drain installation instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing and Table 1 for suggested opening size shadowed and location dimensions The drain overflow of the bath extends below the bottom o...

Page 6: ...BOARD TILE SEALANT TUB ROOFING NAIL 1 x 3 25 x 76mm WOOD STRINGER FULL LENGTH 1 x 3 25 x 76mm WOOD STRINGER FULL LENGTH STEEL STUD WASHER TILE SEALANT TUB 4 102mm DRYWALL SCREW WOOD STUDS STEEL STUDS TYPICAL INSTALLATION CORNER UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED 58 1 2 1486mm 58 1 2 1486mm 25 635mm 25 635mm PUMP ACCESS PANEL ...

Page 7: ...m H 19 483mm L 60 1524mm W 36 914mm H 19 3 8 492mm L 60 1524mm W 60 1524mm H 21 533mm L 72 1829mm W 36 914mm H 19 1 2 495mm L 72 1829mm W 36 914mm H 19 1 2 495mm L 60 1524mm W 32 813mm H 18 3 4 476mm 98 lb 45 kg 98 lb 45 kg 102 lb 46 kg 119 lb 54 kg 103 lb 47 kg 119 lb 54 kg 135 lb 61 kg 418 lb 190 kg 31 lb sq ft 153 kg sq m 418 lb 190 kg 31 lb sq ft 153 kg sq m 414 lb 188 kg 28 lb sq ft 135 kg sq...

Page 8: ... 356mm FLOOR CUTOUT 9 x 14 229 x 356mm FLOOR CUTOUT PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS 0 I 19 1 2 495mm 10 1 4 260mm 60 1524mm 40 1 2 1029mm 32 813mm 16 406mm 0 I 19 1 2 495mm 10 1 4 260mm 40 1 2 1029mm 32 813mm 60 1524mm 16 406mm ...

Page 9: ...x 14 229 x 356mm FLOOR CUTOUT PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS 0 I 10 1 2 267mm 35 1 2 902mm 46 1168mm 48 5 8 1235mm 60 1524mm 35 1 2 902mm 25 1 4 641mm 9 x 14 229 x 356mm FLOOR CUTOUT PROVIDE ACCESS TO PUMP 18 457mm 24 1 2 622mm 8 1 4 209mm 60 1524mm 44 1 2 1130mm 36 914mm ...

Page 10: ...Right hand version shown 9 x 14 229 x 356mm FLOOR CUTOUT 9 x 14 229 x 356mm FLOOR CUTOUT 21 1 2 546mm 10 1 2 267mm 51 1 2 1308mm 36 914mm 72 1829mm 18 457mm PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS 0 I 18 457mm 9 1 2 241mm 42 1067mm 32 813mm 60 1524mm 16 406mm 0 I ...

Page 11: ...y a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped AIR SWITCH WHIRLPOOLS The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired fro...

Page 12: ...pool pump and blower should be installed on a 120 vac 20 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT IS REQUIRED IF THE OPTIONAL HEATER IS INSTALLED SEE INSTALLATION I...

Page 13: ... controls on the Therapy Control Center operate the whirlpool and the bottom three controls operate the air system The whirlpool and air massages systems may be used at the same time if desired The air bath is controlled by a three button control 1 The first button switches the blower on or off The other features will not operate unless the blower is turned on 2 The second button sets the power le...

Page 14: ...and Tile Cleaner Windex Cleaner Mr Clean Cleaner Dow Disinfectant Bathroom Cleaner or other cleaning products in aerosol cans HARSH CHEMICALS SHARP AND ABRASIVE OBJECTS SHOULD NEVER BE USED ON ACRYLIC SURFACES Do not use wire brushes knives or sharp objects to remove stains or other surface blemishes Use of abrasive cleaners or powders will dull the surface If the glossy surface loses its sheen du...

Page 15: ...s for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty 6 ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES INCLUDING THOSE OF...

Reviews: