INSTALLATION INSTRUCTIONS 

MODEL MZC-RM 

3 ZONE RELAY MODULE 

 

Use this product according to this instruction manual.  Please keep this instruction manual for future reference. 

 

NOTE:

  All 

CAUTIONS

 and 

WARNINGS

 are identified by the symbol

  .

 

 

APPLICATION INFORMATION: 

The MZC-RM is a plug-in relay module designed to allow relay control through the MZC-144 Modular Zone Control.  The MZC-RM 
provides a fixed zone group consisting of three relay outputs, two Form C and one selectable (normally open or normally closed) dry 
contacts.  Each of the relay outputs is capable of providing a dry contact, rated at 24VDC at 500mA (resistive load).  

This device is not 

intended for high power switching applications.

  

This device is also not intended for security applications

.  The MZC-RM is 

capable of two different modes of operation, non-latching or latching. 

 

The MZC-RM can be plugged into the MZC-144 at three positions.  Figure 1 shows the MZC-144 PC Board, and the 3 positions where 
the MZC-RM expansion module may be inserted.  Chart 1 shows the single zone dial access codes for activation of the MZC-144 and 
the three positions available to the MZC-RM. 

 

The MZC-144 activates one relay at a time on the MZC-RM.  This is accomplished through the use of the single zone dialing access 
codes set forth in Chart 1.  Through the use of logical zone groups, the MZC-144 can activate multiple relays during activation of the 
MZC-RM.  Logical zone groups, which can be up to five entries, are defined by the user.  When  Logical Zone Groups are programmed 
for use by the MZC-RM, only single zone access codes may be used.  (For additional information on programming logical zone groups, 
see the MZC-144 Installation Instructions (P83259).)  Please note the use of fixed zone group paging and/or an All Call page on the 
MZC-144 will not be acknowledged by the MZC-RM. 

 

 

 

            Figure 

1: 

 

MZC-144 

Board 

and 

MZC-RM 

Positions

 

 

Copyright 1997 Wheelock Inc.  All rights reserved. 

Chart 1:  Single Zone Dial Access Codes 

Summary of Contents for MZC-RM

Page 1: ...ing or latching The MZC RM can be plugged into the MZC 144 at three positions Figure 1 shows the MZC 144 PC Board and the 3 positions where the MZC RM expansion module may be inserted Chart 1 shows the single zone dial access codes for activation of the MZC 144 and the three positions available to the MZC RM The MZC 144 activates one relay at a time on the MZC RM This is accomplished through the u...

Page 2: ...90 102 102 114 114 126 126 138 138 79 079 91 091 103 103 115 115 127 127 139 139 Position 2 80 080 92 092 104 104 116 116 128 128 140 140 81 081 93 093 105 105 117 117 129 129 141 141 82 082 94 094 106 106 118 118 130 130 142 142 Position 3 83 083 95 095 107 107 119 119 131 131 143 143 84 084 96 096 108 108 120 120 132 132 144 144 Legend Zones Access Code Example 7 007 Zone 7 dial access code 007 ...

Page 3: ...4 Figure 2 Installation and Configuration Instructions E1 Shorting Plug Between Pins 1 2 Latching 2 3 Non Latching E2 Shorting Plug Between Pins 1 2 No Contact 2 3 NC Contact Denotes shipped configuration Limited Warranty ...

Page 4: ...ATION ABUSE ACCIDENT OR OTHER OPERATING CONDITIONS BEYOND WHEELOCK S CONTROL SOME WHEELOCK PRODUCTS CONTAIN SOFTWARE WITH RESPECT TO THOSE PRODUCTS WHEELOCK DOES NOT WARRANTY THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR THAT THE SOFTWARE WILL MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR PERFORMANCE OF THE SOFTWARE WILL MEET THE USER S REQUIREMENTS WH...

Reviews: