Pro-Guard & Uni-Guard Installation Manual
26
Noise Condition Display Configuration Table
Value
Function Description
Detection Purpose
0
Shut down tag or noise window display.
Tag window display for channel one.
Detect tag entering vertically.
D1
Tag window display for channel two.
Detect tag entering horizontally.
Average noise window display for channel one.
D2
Average noise window display for channel two.
Monitor average noise.
Note: The average noise level is also weighted by the Minimum Signal Adjustment
value. The D2 value will show the maximum value between average noise and MIN
value.
Key ID H: Minimum signal Adjustment
(Suggested increment: 20; practical range: 0-200)
Decreasing this number will increase system sensitivity but also at the risk of false alarming.
Vice versa, increasing the value will lower system sensitivity to avoid false alarms caused by
uncontrollable environment noise.
There are two antenna channels. Channel 1 is related to vertical orientation and Channel 2 is
related to horizontal orientation. H1 sets the minimum signal of Channel 1, and H2 sets the
minimum signal of Channel 2.
•
Press [MIN] – panel displays as per Figure 7.
•
Input the parameter number.
•
Press [CON] to accept the parameter.
Figure 7.1. Antenna Channel 1
Figure 7.2. Antenna Channel 2