Page 1: ... WF 7910 WF 7910 Q WF 7910 WAGO The Power Converter Accessory model number is located inside the door panel ARTERRA DISTRIBUTION 877 294 8997 wfcoelectronics com WARRANTY warranty wfcoelectronics com Fax 574 294 8698 Distributed by Arterra in the U S A and Canada ...

Page 2: ...INSTALLATION INSTRUCTIONS Mounting the Enclosure 2 Wiring the DC Fuse Board 3 TROUBLESHOOTING INSTRUCTIONS Check Converter or Battery Input Voltage 4 5 Blown Fuse Indicators 5 GENERAL COMPLIANCE INFORMATION Agency Listings 6 CONSUMER LIMITED WARRANTY 6 CONSUMER WARRANTY CLAIM PROCEDURE 7 WARRANTY ASSISTANCE 7 TABLE OF CONTENTS ...

Page 3: ... fuse will blow When this occurs the Red LED for that circuit will illuminate NOTE The fuse board employs surface mount LEDs which are barely visible to the naked eye Replace the blown fuse with a known good fuse of the same rating NOTE If the replacement fuse blows again check that circuit for a short or overload condition NOTICE All wiring must conform to local national and regional regulations ...

Page 4: ...ed in an accessible area such as a wall or inside a cabinet and close to the battery batteries when possible Select a mounting location that is appropriate to prevent excessive heat water moisture dust and dirt entering the unit once installed Cut an opening 1 8 wider than the enclosure to allow the Power Converter Accessory to slide in easily The rough opening is 12 3 16 W x 8 3 16 H The enclosur...

Page 5: ...uld be routed in one of two ways 1 Power could be coming directly into the WF 7910 Series 12V Power Converter Accessory fuse board from the converter charger The battery if supplied would also connect to the fuse board 2 Power from the converter charger would be connected directly to the battery A cable from the battery would be connected to the fuse boards input lugs WE LL USE THE FIRST CONNECTIO...

Page 6: ... 1 on page 4 CHECK FOR CONVERTER OR BATTERY INPUT VOLTAGE NOTE Depending on how the RV manufacturer connected the DC power to the WF 7910 Series 12V Power Converter Accessory it could have been routed in one of 2 ways 1 Power could be coming directly into the WF 7910 Series 12V Power Converter Accessory fuse board from the converter charger The battery if supplied would also connect to the fuse bo...

Page 7: ...lows again check that circuit for a short or overload condition If for some reason one of the fuse board output circuits is connected to a load that has a switch that is turned OFF or an appliance that is turned OFF the indicator LED will not illuminate even if the fuse is blown or removed from the fuse board Turn the switch or appliance ON and re check the fuse circuit with the fuse removed If th...

Page 8: ...ended use are limited in duration unless applicable State Law provides otherwise You may have other rights as specified by each individual state EXCLUSIONS AND LIMITATIONS The OEM warranty specifically does not apply to the following Any WFCO product that has been repaired or altered by an unauthorized person Any damage caused by misuse faulty installation testing negligence accident or any WFCO p...

Page 9: ...ty Department at 574 294 8698 After receipt of the forms an RGA number will be issued This number shall appear on all correspondence with warranty service Upon validation of the warranty WFCO shall replace the product with a like product The RGA number shall be placed on the outside of the carton used to return the product for ease of identification Do not mark directly on the product The product ...